CORTRAK 2 EAS Electromagnetic Transmitting Stylet and CORFLO Feeding Tube 20-9368TRAK2Recalls & reported problems
Corpak Medsystems, Inc. · Feeding tube non weighted with stylet for use with CORTRAK 2 Enteral Access System · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10815149023882), received between Oct 20, 2017 and Oct 20, 2017 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break2
Patient problems
- No Code Available2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 20, 2017Break; Break
IT WAS REPORTED VIA FDA MAUDE REPORT KEY (B)(4): "CORTRAK BROKE UPON REMOVAL, LEAVING TUBING BEHIND THAT HAD TO BE REMOVED BY GI PROCEDURES." THERE WAS NO REPORTED PATIENT INJURY. NO FURTHER INFORMATION WAS AVAILABLE.
Patient problems: No Code Available
MAUDE report 6965538 ↗MalfunctionOct 20, 2017Break; Break
IT WAS REPORTED VIA FDA MAUDE REPORT KEY (B)(4): "ELDERLY FEMALE ADMITTED TO BURN UNIT FOR 23% TOTAL BODY SURFACE AREA (TBSA) BURN. CORTRAK PLACED ABOUT THREE WEEKS LATER AND REMOVED ABOUT A MONTH AFTER INSERTION WHEN IT WAS NOTED THAT THE PATIENT HAD TUBE FEEDS COMING OUT OF HER MOUTH WHEN MEDICATIONS WERE ADMINISTERED THROUGH THE ADJACENT NG TUBE. THE CORTRAK BROKE OFF AT THE 20 CM MARK. THE EXISTING TIP OF THE TUBE APPEARS TO BE RUPTURED. APPROXIMATELY 20 CM OF THE END OF THE CORTRAK WAS RETAINED IN THE STOMACH. IT WAS SUCCESSFULLY REMOVED ON THE SAME DAY VIA BEDSIDE EGD."
Patient problems: No Code Available
MAUDE report 6965536 ↗
Other TUBES, GASTROINTESTINAL (AND ACCESSORIES) devices
- Bard® DigniShield® Stool Management System SMS002C. R. Bard, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)2 deaths525 reports
- CORTRAK* 2 ENTERAL ACCESS SYSTEM 20-0950Avanos Medical, Inc. · Tubes, gastrointestinal (and accessories)1 recall22 deaths134 reports
- Bard Tri-Funnel Replacement Gastrostomy Tube 000720Bard Access Systems, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)1 death170 reports
- EndoVive Safety PEG Kit M00566470Boston Scientific Corporation · TUBES, GASTROINTESTINAL (AND ACCESSORIES)1 recall1 death111 reports
- Kangaroo 8884711253Cardinal Health, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)152 reports
- NutraGlide Nasal Feeding Tube ENFT-06090-IApplied Medical Technology, Inc. · Tubes, Gastrointestinal (And Accessories)2 recalls0 reports
- NutraGlide Nasal Feeding Tube ENFT-05090-IApplied Medical Technology, Inc. · Tubes, Gastrointestinal (And Accessories)2 recalls0 reports
- Kangaroo 8884711253ECardinal Health, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)100 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page