Cantata G34583Recalls & reported problems
Cook Incorporated · Cantata, 2.9 Microcatheter · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10827002345833), received between Mar 10, 2017 and Aug 22, 2023 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Material Separation” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Material Separation2
- Device-Device Incompatibility1
- Difficult to Advance1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 22, 2023Material Separation; Device-Device Incompatibility; Difficult to Advance; Material Separation; Device-Device Incompatibility; Difficult to Advance
ADDITIONAL INFORMATION WAS PROVIDED. AS REPORTED, THE PROCEDURE WAS TO TREAT A RLL (RIGHT LOWER LOBE) PAVM (PULMONARY ARTERIOVENOUS MALFORMATION). THE FEEDING PULMONARY ARTERY WAS SOMEWHAT TORTUOUS BUT NOT CALCIFIED; HOWEVER, THE TORTUOSITY WAS NOT OUT OF THE ORDINARY FOR A PAVM. THE PHYSICIAN ROUTINELY USES THE CANTATA IN THIS AREA. IN THIS EVENT, A 0.035 WIRE GUIDE AND A 0.014 WIRE GUIDE ADVANCED TO THE DISTAL FEEDING PULMONARY ARTERY WITHOUT DIFFICULTY. HOWEVER, THE CANTATA CATHETER WOULD NOT ADVANCE WELL OVER THE WIRE. DURING ATTEMPTED ADVANCEMENT OF A VASCULAR PLUG THROUGH THE CANTATA, THE PLUG BECAME STUCK AND WOULD NOT ADVANCE. AFTER THE PLUG WAS REMOVED, SMALL PARTICLES IN THE BLOOD WERE NOTED DURING ASPIRATION. THE CANTATA WAS SUBSEQUENTLY REMOVED AND EXAMINED; IT WAS DISCOVERED THAT THE COATING SEEMED TO BE MISSING. ADDITIONAL BLOOD WAS RAPIDLY ASPIRATED FROM THE FEEDING PULMONARY ARTERY. THERE WAS A HIGH RISK FOR PARADOXICAL EMBOLIZATION AND COMPLICATION AS THIS OCCURRED AT THE LOCATION OF THE AVM. THEN AN ADDITIONAL 2.9 FRENCH CANTATA WAS OBTAINED AND WAS EASILY ADVANCED TO THE AVM SITE FOR SUCCESSFUL EMBOLIZATION WITH THE VASCULAR PLUG.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17596809 ↗MalfunctionMar 10, 2017Material Separation; Material Separation
INTERNATIONAL DISTRIBUTOR REPORTED THAT THE WHITE HUB OF THE CANTATA DETACHED WHILE ATTEMPTING TO INSERT THE DEVICE FOR A UTERINE FIBROID EMBOLIZATION PROCEDURE. THERE ARE NO REPORTED ADVERSE PATIENT CONSEQUENCES ASSOCIATED WITH THIS EVENT. NO LEAKS OR OTHER SEPARATIONS WERE NOTED. THE DEVICE WAS DISPOSED AT THE USER FACILITY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6395139 ↗
FDA clearance and classification
The FDA regulates product code KRA (catheter, continuous flush) under 21 CFR 870.1210 as a Class II device. 21 CFR 870.1210 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Cantata G34583
Has the Cantata G34583 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10827002345833), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Cantata G34583?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between Mar 10, 2017 and Aug 22, 2023. In those reports, the most common specific device problems are “Material Separation” (2), “Device-Device Incompatibility” (1) and “Difficult to Advance” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Cantata G34583?
None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Cantata G34583, and is it still sold?
The FDA's device database lists Cook Incorporated as the company responsible for it (brand Cantata, model G34583). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Catheter, continuous flush devices
- PROWLER SELECT 606-S255XMedos International Sàrl · Catheter, continuous flush2 deaths973 reports
- PhenomTM 27 Catheter FG15150-0615-1SMicro Therapeutics, Inc. · Catheter, continuous flush2 deaths139 reports
- MarathonTM 105-5056Micro Therapeutics, Inc. · Catheter, continuous flush124 reports
- Renegade™ HI-FLO™ Kit M001183020Boston Scientific Corporation · Catheter, continuous flush109 reports
- MarksmanTM FA-55150-1030Micro Therapeutics, Inc. · Catheter, continuous flush109 reports
- EkoSonic® 6779-002Boston Scientific Corporation · Catheter, Continuous Flush1 recall4 deaths55 reports
- Chameleon CH08-40-75USMozarc Medical US LLC · Catheter, continuous flush2 recalls4 reports
- RebarTM 105-5081-153Micro Therapeutics, Inc. · Catheter, continuous flush2 deaths102 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page