Zenith Alpha G35400Recalls & reported problems
William Cook Europe ApS · Zenith Alpha, Thoracic Endovascular Graft, Distal Component · Class 3 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10827002354002), received between Oct 20, 2016 and Oct 20, 2016 — classified as 1 malfunction.
The most frequently reported specific device problem is “Activation, Positioning or Separation Problem” (1 report).
2 other recalls cover devices cleared under the same FDA submission (P140016); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Activation, Positioning or Separation Problem1
- Difficult to Remove1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 20, 2016Difficult to Remove; Activation, Positioning or Separation Problem; Difficult to Remove; Activation, Positioning or Separation Problem
DESCRIPTION OF EVENT ACCORDING TO THE INITIAL REPORTER: DURING THE TEVAR PROCEDURE, THE PHYSICIAN ATTEMPTED TO LAND THE ZENITH ALPHA THORACIC ENDOVASCULAR GRAFT AT THE LEFT COMMON CAROTID ARTERY. AS THE DEVICE STARTED TO DEPLOY IT JUMPED BACK 4.5 CM ((B)(4)). THE REST OF THE DEVICE DEPLOYED IN THE NORMAL MANOR AND RELEASED FROM THE DELIVERY SYSTEM WITH NO PROBLEMS. DUE TO THE 4.5 CM GAP BETWEEN THE INTENDED LANDING ZONE AND THE ACTUAL LANDING ZONE, A ZTA-P-46-125-W GRAFT WAS SUCCESSFULLY PLACED LANDING WITH THE PROXIMAL GRAFT EDGE AT THE OSTIUM OF THE LEFT COMMON CAROTID ARTERY. AT THIS TIME A ZTA-D-42-204-W DEVICE WAS UTILIZED AND WENT THROUGH THE DEPLOYMENT DEVICE SEQUENCE IN THE PROPER ORDER. HOWEVER, THE DISTAL BARE STENT APPEARED TO BE STUCK IN THE BOTTOM CAP OF THE DELIVERY SYSTEM. THE HANDLE WAS DISMANTLED AND THE PHYSICIAN PULLED OFF ALL THE TRIGGER WIRES . THE PHYSICIAN PULLED THE GREY POSITIONER DOWN TO THE BOTTOM OF THE DEVICE TOUCHING THE BOTTOM OF THE STENT GRAFT BUT THE REVERSE TAPERED DILATOR TIP OF THE STENT GRAFT BARE METAL STENT AND COULD NOT BE REMOVED. IT WAS THEN NOTED THAT THE BARE STENT MUST HAVE CROSSED ON ITSELF AT THE STENT APICES ((B)(4)). AT THIS POINT A
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6042809 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P140016. One submission often covers many models, so check the product and lot details in each record.
- Z-0043-2026 · Sep 18, 2025 · Open, ClassifiedZenith Alpha 2 Thoracic Endovascular Graft, Catalog Prefix ZTA2- Reference Part Numbers ZTA2-P-40-117-W ZTA2-P-40-167 ZTA2-P-40-167-W ZTA2-P-40-217-W ZTA2-P-42-121 ZTA2-P-42-121-W
- Z-2099-2017 · Mar 22, 2017 · TerminatedZenith Alpha Thoracic Endovascular Graft The Zenith Alpha" Thoracic Endovascular Graft is indicated for the endovascular treatment of patients with isolated lesions of the descend
Other SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page