Skip to content

Zilver PTX G38488Recalls & reported problems

Cook Ireland Ltd · Zilver PTX, Drug-Eluting Peripheral Stent · Class 3 · Implant

All models of Zilver PTX (28)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
14
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 14 adverse event reports that list this exact device (DI 10827002384887), received between Dec 21, 2016 and Mar 3, 2026 — classified as 4 injuries, 10 malfunctions.

The most frequently reported specific device problem is “Activation, Positioning or Separation Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 2 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Activation, Positioning or Separation Problem3
  • Improper or Incorrect Procedure or Method3
  • Material Deformation3
  • Off-Label Use2
  • Break1
  • Delivery System Failure1
  • Difficult to Remove1
  • Expiration Date Error1

Patient problems

  • No Known Impact Or Consequence To Patient5
  • No Clinical Signs, Symptoms or Conditions4
  • Foreign Body In Patient2
  • No Consequences Or Impact To Patient2
  • No Code Available1

Recent adverse event reports

The 14 most recent of 14 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 3, 2026Improper or Incorrect Procedure or Method

    AS REPORTED VIA EMAIL: "ONE OF MY PHYSICIANS USED ZILVER PTX DURING A PROCEDURE LAST WEEK, AND THE STENT MOVED DURING DEPLOYMENT. THE PHYSICIAN IS A VASCULAR SURGEON WHO IS NOT VERY EXPERIENCED WITH ENDOVASCULAR PROCEDURES. IT WAS HIS FIRST TIME USING ZILVER PTX. AN INTEGRATED ACCESS APPROACH WAS DONE. THE PATIENT WAS ELDERLY AND HAD SEVERE PERIPHERAL ARTERIAL DISEASE. CROSSING THE LESION WAS CHALLENGING, AS THE VESSEL WAS HIGHLY STENOTIC AND CALCIFIED. BECAUSE THE ACCESS WAS INTEGRATED AND POSITIONED ON THE OPPOSITE SIDE OF THE TABLE, THE DR WAS WORKING IN AN UP-AND-OVER POSITION BUT OUTSIDE OF THE PATIENT. AT THE TIME OF STENT DEPLOYMENT, THE SYSTEM WASN¿T STABILIZED PROPERLY AND THE STENT MOVED. AFTER DISCUSSION WITH COLLEAGUES, IT SEEMS THAT IT IS A USER ERROR." WHAT WAS THE DATE OF THE OCCURRENCE? FEBRUARY 2ND. WILL THE FACILITY BE REPORTING THIS TO A GOVERNMENT AGENCY (FDA, COMPETENT AUTHORITY, ETC.) NO. USAGE OF PRODUCT: INITIAL USE OF DEVICE. IS THE DEVICE AVAILABLE FOR RETURN? NO DID THE PATIENT REQUIRE ANY ADDITIONAL INTERVENTIONS/PROCEDURES OR EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS EVENT? NO WERE BOTH OF THOSE DEVICES USED IN THE SAME PATIENT? YES WHAT WAS THE ACCESS

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24495519 ↗
  • InjuryOct 7, 2024Off-Label Use; Off-Label Use

    PHYSICIAN WAS ATTEMPTING TO PLACE A 7MM/80MM ZILVER PTX IN A PATIENT¿S TRANSVERSE SINUS (OFF OF IFU). WHEN SCROLLING THE THUMB WHEEL BACK TO DEPLOY THE STENT THE WHEEL STOPPED TURNING LEAVING HALF OF THE STENT DEPLOYED AND HALF OF THE STENT UNDEPLOYED. I WAS CALLED AND WITH THE SITUATION DESCRIBED I INSTRUCTED THEM TO TAKE APART THE HANDLE AND PULL ON THE WIRE INSIDE TO FINISH DEPLOYING THE STENT. AFTER THAT DID NOT WORK, THEY FACETIMED ME AND I SAW THAT THE SHEATH LOOKED TO BE SEVERED. THAT WAS UNKNOWN BEFORE I INSTRUCTED THEM TO PULL THE WIRE INSIDE OF THE HANDLE. THEY ASKED ME TO COME IN TO TRY TO HELP. WHILE THIRTY MINUTES OUT FROM THE HOSPITAL I ASKED FOR AN UPDATE, AND THEY SAID VASCULAR SURGERY CAME BY AND PULLED IT OUT. THE SHEATH CAME OUT WITH ALL THE PIECES ATTACHED BUT BROKE THE STENT. HALF OF THE STENT IS RETAINED IN THE PATIENT WITH NO ISSUE AS OF THIS MOMENT. WHEN I LOOKED AT THE DEVICE, THE OUTER SHEATH WAS BROKEN, THE INNER PIECE THAT RETRACTS WAS BROKEN AND UNWOUND, AND THE NOSE CONE WAS STILL ATTACHED WITH PIECES OF THE BROKEN STENT. THEY HAVE THE DEVICE TO SEND BACK BUT I WAS TOLD THE HOSPITAL MUST LOOK AT THE DEVICE FIRST BEFORE IT¿S TURNED OVER TO ME. I SAID IT

    Patient problems: Foreign Body In Patient

    MAUDE report 20392816 ↗
  • InjuryOct 3, 2024Off-Label Use; Off-Label Use

    ACCORDING TO THE INITIAL REPORTER, THE PHYSICIAN WAS ATTEMPTING TO PLACE A 7MM/80MM ZILVER PTX IN A PATIENT¿S TRANSVERSE SINUS (OFF OF IFU). WHEN SCROLLING THE THUMB WHEEL BACK TO DEPLOY THE STENT THE WHEEL STOPPED TURNING LEAVING HALF OF THE STENT DEPLOYED AND HALF OF THE STENT UNDEPLOYED. I WAS CALLED AND WITH THE SITUATION DESCRIBED I INSTRUCTED THEM TO TAKE APART THE HANDLE AND PULL ON THE WIRE INSIDE TO FINISH DEPLOYING THE STENT. AFTER THAT DID NOT WORK, THEY FACETIMED ME AND I SAW THAT THE SHEATH LOOKED TO BE SEVERED. THAT WAS UNKNOWN BEFORE I INSTRUCTED THEM TO PULL THE WIRE INSIDE OF THE HANDLE. THEY ASKED ME TO COME IN TO TRY TO HELP. WHILE THIRTY MINUTES OUT FROM THE HOSPITAL I ASKED FOR AN UPDATE, AND THEY SAID VASCULAR SURGERY CAME BY AND PULLED IT OUT. THE SHEATH CAME OUT WITH ALL THE PIECES ATTACHED BUT BROKE THE STENT. HALF OF THE STENT IS RETAINED IN THE PATIENT WITH NO ISSUE AS OF THIS MOMENT. WHEN I LOOKED AT THE DEVICE, THE OUTER SHEATH WAS BROKEN, THE INNER PIECE THAT RETRACTS WAS BROKEN AND UNWOUND, AND THE NOSE CONE WAS STILL ATTACHED WITH PIECES OF THE BROKEN STENT. THEY HAVE THE DEVICE TO SEND BACK BUT I WAS TOLD THE HOSPITAL MUST LOOK AT THE DEVICE FIRST B

    Patient problems: Foreign Body In Patient

    MAUDE report 20358219 ↗
  • MalfunctionJun 2, 2023Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method

    PER MEDWATCH FORM: PATIENT UNDERWENT DIAGNOSTIC ARTERIOGRAM AND TRANSCATHETER INTERVENTION; FIRST STENT WAS DEPLOYED (PR 396544 LOT C1741457), AND MD REQUESTED AN ADDITIONAL STENT. PRIOR TO PLACEMENT, IT WAS DISCOVERED THE DATE ON THE STENT PACKAGING WAS EXPIRED (B)(6)2022. (PR (B)(6) LOT C1769805) DATE OF IMPLANT: (B)(6)2022. PATIENT OUTCOME: N/A - OCCURRENCE WAS DISCOVERED PRIOR TO PATIENT CONTACT. SG (B)(6)2023. PATIENT/EVENT INFO - NOTES: PLEASE PROVIDE THE ORIGINATOR A LIST OF ANY ADDITIONAL MANUFACTURER QUESTIONS REQUIRED FOR INVESTIGATION. SG (B)(6)2023 THE FOLLOWING INFORMATION HAS BEEN REQUESTED VIA EMAIL ON (B)(6)2023. SG (B)(6)2023 IN THE SECTION ¿DESCRIBE EVENT¿ THE STATEMENT ¿FIRST STENT WAS DEPLOYED, AND MD REQUESTED AN ADDITIONAL STENT. PRIOR TO PLACEMENT, IT WAS DISCOVERED THE DATE ON THE STENT PACKAGING WAS EXPIRED (B)(6)2022.¿ WAS G38489 ¿ LOT C1741457 THE 1ST STENT PLACED? IF SO WAS IT REMOVED DUE TO THE EXPIRATION DATE, OR WAS IT JUST A STENT THAT YOU HAD ON HAND AND NOT USED? ALSO PLEASE CONFIRM THAT THE SECOND EXPIRED STENT WAS NOT USED ON THE PATIENT?

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17049716 ↗
  • MalfunctionJul 8, 2021Improper or Incorrect Procedure or Method; Material Deformation; Improper or Incorrect Procedure or Method; Material Deformation

    THIS SUPPLEMENTAL REPORT IS BEING SUBMITTED DUE TO COMPLETION OF THE INVESTIGATION ON THE 07-APR-2023

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12133733 ↗
  • InjuryJun 30, 2021Material Deformation; Material Deformation

    ACCORDING TO THE INITIAL REPORTER: "DEVICE BUNCHED UP IN THE CENTER DURING DEPLOYMENT. USER WAS ABLE TO FULLY DEPLOY IT AND DIDN'T NOTICE ISSUE UNTIL AFTER DEPLOYMENT. THEY WERE ABLE TO BALLOON IT TO RE-EXPAND IT (IN DIAMETER), BUT MAY HAVE TO BRING PATIENT BACK TO CHECK IT AND POSSIBLY EXTEND IT AS IT IS STILL SHORTENED (LOOKS LIKE ABOUT A 60 INSTEAD OF AN 80). LONG OCCLUSION OF THE SFA. PICTURES AVAILABLE."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12091596 ↗
  • MalfunctionApr 23, 2020Expiration Date Error; Expiration Date Error

    AS REPORTED TO CUSTOMER RELATIONS PER VERBAL DISCUSSION WITH THE DISTRICT MANAGER: PATIENT UNDERWENT A PROCEDURE IN WHICH THE ZILVER PTX 35 DRUG-ELUTING STENT, G38488, WAS USED. THE DEVICE WAS IMPLANTED AS EXPECTED WITH NO DIFFICULTIES. THE MEDICAL STAFF NOTED AFTER PROCEDURE WAS COMPLETE THAT THE DEVICE WAS EXPIRED BY 8 DAYS. DUE TO THIS THE FACILITY WANTED TO REPORT IT TO THE MANUFACTURE FOR AWARENESS. 1. DID ANY UNINTENDED SECTION OF THE DEVICE REMAIN INSIDE THE PATIENT¿S BODY? NO. IF YES, PLEASE DESCRIBE. 2. DID THE PATIENT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE? NO. IF YES, PLEASE DESCRIBE. 3. DID THE PRODUCT CAUSE OR CONTRIBUTE TO THE NEED FOR ADDITIONAL PROCEDURES? NO. IF YES, PLEASE SPECIFY ADDITIONAL PROCEDURES AND PROVIDE DETAILS. 4. HAS THE COMPLAINANT REPORTED ANY ADVERSE EFFECTS ON THE PATIENT DUE TO THIS OCCURRENCE? NO. 5. HAS THE COMPLAINANT REPORTED THAT THE PRODUCT CAUSED OR CONTRIBUTED TO THE ADVERSE EFFECTS? NO. PLEASE SPECIFY ADVERSE EFFECTS AND PROVIDE DETAILS.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9991394 ↗
  • MalfunctionOct 25, 2019Activation, Positioning or Separation Problem; Activation, Positioning or Separation Problem

    REPORTED BY THE DM VIA PHONE CALL- DURING THE PROCEDURE BOTH STENTS DID NOT DEPLOY EVENLY. THEY DEPLOYED FULLY, BUT WERE CRUNCHED UP. BOTH STENTS ARE IMPLANTED IN THE PATIENT. FDA MDR REPORTING REQUIRED: EVENT IS FDA MDR REPORTABLE BASED ON THE DEVICE MALFUNCTION REPORTING PRECEDENCE FOR THIS DEVICE FAMILY FOR THE ISSUE OF 'STENT SHORTENING OR COMPRESSION DURING DEPLOYMENT' . NO ADVERSE EFFECTS TO THE PATIENT HAVE BEEN REPORTED AS OCCURRING.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9237227 ↗
  • MalfunctionOct 8, 2019Activation, Positioning or Separation Problem; Activation, Positioning or Separation Problem

    REPORTED BY PHONE CALL FROM THE DM- WHEN ATTEMPTING TO PLACE THE FIRST STENT, THE STENT WOULD NOT GO THROUGH THE LESION BUT THE SECOND STENT WENT PAST THE LESION AND WAS ABLE TO CROSS. IT IS BELIEVED SOMETHING IS WRONG WITH THE DELIVERY SYSTEM OF THE FIRST STENT. FDA MDR REPORTING REQUIRED: EVENT IS FDA MDR REPORTABLE BASED ON THE DEVICE MALFUNCTION REPORTING PRECEDENCE FOR THIS DEVICE FAMILY FOR THE ISSUE OF ¿THUMBWHEEL MALFUNCTIONS DURING DEPLOYMENT¿. NO ADVERSE EFFECTS TO THE PATIENT HAVE BEEN REPORTED AS OCCURRING. THIS REPORT IS BEING SUBMITTED AS A CANCELLATION REPORT. FROM THE INITIAL INFORMATION RECEIVED, THIS EVENT WAS CAUTIOUSLY MADE REPORTABLE BASED ON THE PRECEDENCE IN PLACE FOR THIS DEVICE OF 'THUMBWHEEL MALFUNCTIONS DURING DEPLOYMENT¿. HOWEVER, WHEN THE RETURNED DEVICE WAS RECEIVED IT WAS CONFIRMED DURING THE LAB EVALUATION THAT THIS MALFUNCTION DID NOT OCCUR. THE FOLLOWING FAILURE HAS BEEN CONFIRMED: "RETRACTION SHEATH CANNOT REACH TARGET SITE". OVERALL RISK ASSESSED AS CATEGORY IIA (LOW). NO REPORTING MALFUNCTION PRECEDENCE EXISTS FOR THIS COMPLAINT EVENT FOR THIS PRODUCT FAMILY. LOW RISK OF FAILURE MODE INDICATES NO POTENTIAL FOR SERIOUS INJURY IF THE MALFUNCTION W

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9165125 ↗
  • MalfunctionJul 25, 2018Material Deformation; Material Deformation

    THIS FOLLOW UP MDR IS BEING SUBMITTED TO CANCEL THE INITIAL REPORT. THIS FILE ADDRESSES THE FIRST STENT IMPLANTED WHICH WAS DAMAGED BY THE SECOND STENT: AS REPORTED TO CUSTOMER RELATIONS: "CAUGHT PROXIMAL EDGE WITH A SUBSEQUENT STENT AND FOLDED THE 6X140 IN ON ITSELF. HAD TO REMOVE THE SUBSEQUENT SYSTEM AND HAD TROUBLE GETTING CATHETER PAST OVERLAPPED SEGMENT TO RETRIEVE AN EMBOLIC FILTER. EVENTUALLY ABLE TO RETRIEVE FILTER AND BALLOONED THE FOLDED IN SEGMENT OF THE INITIAL PTX. AT THAT POINT, PLACED LONGER, SUBSEQUENT STENT THROUGH THAT END WITH GOOD ANGIOGRAPHIC RESULTS." DM BELIEVES THIS MIGHT BE A WIRE-GUIDE COMPATIBILITY ISSUE--WORKING ON .014 WIRE WITH .035 STENT, SO THE MISMATCH MIGHT BE THE PROBLEM. NOTHING AVAILABLE FOR RETURN (FIRST DEVICE REMAINS IN PATIENT, SECOND DEVICE DISCARDED)." ADDITIONAL INFORMATION PROVIDED BY DM ON 05JUL2018: "(CAN YOU CONFIRM IF THE STENT FRACTURED AT ALL WHEN IT CRUMPLED?) I CANNOT CONFIRM STENT FRACTURE. IT DID NOT APPEAR TO FRACTURE THOUGH."

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7718490 ↗
  • MalfunctionAug 22, 2017Difficult to Remove; Difficult to Remove

    THIS INITIAL REPORT IS BEING SUBMITTED DUE TO THE MALFUNCTION PRECEDENCE: "DELIVERY SYSTEM CANNOT BE WITHDRAWN". THIS REPORT FORMS PART OF RETROSPECTIVE REVIEW OF OPEN COMPLAINTS FOR A NEW MALFUNCTION PRECEDENCE FOR THIS DEVICE FAMILY. STENT CATHETER WAS FLUSHED AND PREPPED ACCORDING TO IFU, STENT CATHETER TRACKED INTO THE BODY FINE WITH NO RESISTANCE. AFTER STENT WAS DEPLOYED, WITHOUT ERROR, STENT CATHETER BECAME "STUCK" ON THE WIRE. STENT CATHETER AND WIRE WERE THEN REMOVED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6810553 ↗
  • MalfunctionJul 13, 2017Delivery System Failure; Delivery System Failure

    THIS FOLLOW-UP MDR IS BEING SUBMITTED TO INCLUDE A ROOT CAUSE FOR THIS COMPLAINT ISSUE. INITIAL REPORT DETAILS: STENT CATHETER WAS FLUSHED AND PREPPED ACCORDING TO IFU, STENT CATHETER TRACKED INTO THE BODY FINE WITH NO RESISTANCE. AFTER STENT WAS DEPLOYED, WITHOUT ERROR, STENT CATHETER BECAME "STUCK" ON THE WIRE. STENT CATHETER AND WIRE WERE THEN REMOVED. ON EVALUATION OF THE COMPLAINT DEVICE ON 15-JUL-17 IT WAS OBSERVED THAT THE RETRACTION WIRE HAD SEPARATED FROM THE STENT RETRACTION SHEATH. EVENT IS FDA MDR REPORTABLE BASED ON THE DEVICE MALFUNCTION REPORTING PRECEDENCE FOR THIS DEVICE FAMILY FOR THE ISSUE OF 'RETRACTION WIRE SEPARATES FROM RETRACTION SHEATH.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6710717 ↗
  • MalfunctionJun 1, 2017Stretched; Stretched

    THIS FOLLOW UP REPORT IS BEING SUBMITTED DUE TO THE EVALUATION OF THE DEVICE INVOLVED IN THIS EVENT AND THE CONCLUSION OF THIS INVESTIGATION. INITIAL REPORT DETAILS: AS REPORTED TO CUSTOMER RELATIONS: "DURING THE PROCEDURE IT APPEARED THE STENT HAD ELONGATED. THE STENT SEEMS TO MEASURE 9.5MM INSTEAD OF 8MM. THE PHYSICIAN PUT AN 80 BALLOON IN AND CAME UP SHORT. THE STENT LANDED IN A GOOD SPOT AND THE PROCEDURE WENT WELL. PATIENT WAS RELEASED TO GO HOME."

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6604121 ↗
  • InjuryDec 21, 2016Break; Activation, Positioning or Separation Problem; Break; Activation, Positioning or Separation Problem

    THIS FOLLOW UP REPORT IS BEING SUBMITTED DUE TO THE EVALUATION OF THE DEVICE INVOLVED IN THIS EVENT AND THE UPDATE TO THE CONCLUSION OF THIS INVESTIGATION. INITIAL REPORT DETAILS: THE FACILITY PLACED A ZILVER PTX 7X120 WITH NO INCIDENT. THE FACILITY WENT TO OVERLAP WITH A SECOND ZILVER PTX 7X80 IN THE RIGHT SFA, DISTAL TO MID-LESION. APPROXIMATELY 40 MM'S OF THE STENT WAS DEPLOYED. AT THAT POINT THE THUMB WHEEL SYSTEM BROKE. THE PHYSICIAN ASKED FOR THE DM TO BE CALLED AND THE ZILVER PRODUCT MANAGER WAS CALLED. WHILE THEY WERE ON THE PHONE SPEAKING WITH OUR COOK REPRESENTATIVES, THE PHYSICIAN ATTEMPTED TO PULL THE ENTIRE DELIVERY SYSTEM (WITH THE STENT) OUT OF THE PATIENT. THE DOCTOR WAS ABLE TO REMOVE THE DELIVERY SYSTEM AND THE STENT, BUT APPROXIMATELY 20MM'S BROKE OFF AND WAS LEFT IN THE PATIENT'S COMMON ILIAC. THE BROKEN PORTION OF THE DEVICE IS STILL INSIDE THE PATIENT. THE PATIENT EMBOLIZED THE LOWER LEG AND WAS PLACED ON A TPA DRIP AND WILL BE BROUGHT BACK TO THE LAB IN THE AFTERNOON FOR RE-EVALUATION.

    Patient problems: No Code Available

    MAUDE report 6192615 ↗

Other Stent, superficial femoral artery, drug-eluting devices

All Stent, superficial femoral artery, drug-eluting devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page