COOK G47440Recalls & reported problems
William Cook Europe ApS · Zenith TX2, Dissection Endovascular Graft with Pro-form, and the Z-Trak Plus Introduction System-Straight Component · Class 3 · Implant
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10827002474403), received between Jan 3, 2023 and Jan 11, 2023 — classified as 3 injuries.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Device Dislodged or Dislocated2
- Adverse Event Without Identified Device or Use Problem1
- Improper or Incorrect Procedure or Method1
- Malposition of Device1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Vascular Dissection1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryJan 11, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated
DESCRIPTION OF EVENT ACCORDING TO INITIAL REPORTER: PATIENT CAME IN FOR A DISSECTION EMERGENT CASE. DURING DEPLOYMENT OR USER AGGRESSION THE GRAFT LANDED DISTAL TO WHERE THE ACTUAL APPROX LANDING ZONE WANTED TO BE ((B)(4)). THE PHYSICIAN DECIDED TO USE A DEVICE FROM ANOTHER MANUFACTURER TO GET MORE OF A PROXIMAL SEAL. DELIVERED THE DEVICE THEN DISTALITY HE EXTENDED OUT THE ZDES-36-180-US. UPON FINAL RUN HE WAS SATISFIED WITH THE FINAL ANGIO. FAST FORWARD TO RECENTLY WITHIN THE LAST WEEK THE PATIENT HAD TO COME BACK IN WITH A TYPE A DISSECTION TO WHERE THEY HAD TO BUILD THE ARCH ((B)(4)). PATIENT OUTCOME: THE PATIENT WAS PROLONGED HOSPITALIZED FOR RECOVERY. FURTHERMORE, THE PATIENT HAD TO RETURN FOR COMPLETE ARCH REPAIR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16141838 ↗InjuryJan 3, 2023Improper or Incorrect Procedure or Method; Device Dislodged or Dislocated; Improper or Incorrect Procedure or Method; Device Dislodged or Dislocated
DESCRIPTION OF EVENT ACCORDING TO INITIAL REPORTER: PATIENT CAME IN FOR A DISSECTION EMERGENT CASE. DURING DEPLOYMENT OR USER AGGRESSION THE GRAFT LANDED DISTAL TO WHERE THE ACTUAL APPROX LANDING ZONE WANTED TO BE ((B)(4)). THE PHYSICIAN DECIDED TO USE A DEVICE FROM ANOTHER MANUFACTURER TO GET MORE OF A PROXIMAL SEAL. DELIVERED THE DEVICE THEN DISTALITY HE EXTENDED OUT THE ZDES-36-180-US. UPON FINAL RUN HE WAS SATISFIED WITH THE FINAL ANGIO. FAST FORWARD TO RECENTLY WITHIN THE LAST WEEK THE PATIENT HAD TO COME BACK IN WITH A TYPE A DISSECTION TO WHERE THEY HAD TO BUILD THE ARCH ((B)(4)). PATIENT OUTCOME: THE PATIENT WAS PROLONGED HOSPITALIZED FOR RECOVERY. FURTHERMORE, THE PATIENT HAD TO RETURN FOR COMPLETE ARCH REPAIR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16085023 ↗InjuryJan 3, 2023Malposition of Device; Adverse Event Without Identified Device or Use Problem; Malposition of Device; Adverse Event Without Identified Device or Use Problem
DESCRIPTION OF EVENT ACCORDING TO INITIAL REPORTER: PATIENT CAME IN FOR A DISSECTION EMERGENT CASE. DURING DEPLOYMENT OR USER AGGRESSION THE GRAFT LANDED DISTAL TO WHERE THE ACTUAL APPROX LANDING ZONE WANTED TO BE (PR384167). THE PHYSICIAN DECIDED TO USE A DEVICE FROM ANOTHER MANUFACTURER TO GET MORE OF A PROXIMAL SEAL, DELIVERED THE DEVICE THEN DISTALITY HE EXTENDED OUT THE ZDES-36-180-US UPON FINAL RUN HE WAS SATISFIED WITH THE FINAL ANGIO. FAST FORWARD TO RECENTLY WITHIN THE LAST WEEK THE PATIENT HAD TO COME BACK IN WITH A TYPE A DISSECTION TO WHERE THEY HAD TO BUILD THE ARCH (PR384229). PATIENT OUTCOME: THE PATIENT WAS PROLONGED HOSPITALIZED FOR RECOVERY. FURTHERMORE, THE PATIENT HAD TO RETURN FOR COMPLETE ARCH REPAIR.
Patient problems: Vascular Dissection
MAUDE report 16084903 ↗
Other SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.