Advance G49479Recalls & reported problems
Cook Incorporated · Advance, 18LP Low Profile PTA Balloon Dilatation Catheter · Class 2
All models of Advance (206)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10827002494791), received between Jun 16, 2017 and May 9, 2023 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Fluid/Blood Leak1
- Material Puncture/Hole1
- Material Rupture1
- Material Separation1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 9, 2023Fluid/Blood Leak; Material Puncture/Hole; Fluid/Blood Leak; Material Puncture/Hole
NO ADDITIONAL INFORMATION REGARDING THE PATIENT AND/OR EVENT HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16897243 ↗MalfunctionJun 16, 2017Material Rupture; Material Separation; Material Rupture; Material Separation
AN INTERNATIONAL CUSTOMER REPORTED THAT DURING AN ATTEMPTED TREATMENT OF A DISTAL POPLITEAL ARTERY ANGIOPLASTY, SUPERFICIAL FEMORAL ARTERY (SFA) PLASTY, AND COMMON FEMORAL ARTERY (CFA) PLASTY; THE ADVANCE 18 LOW PROFILE BALLOON CATHETER FAILED AND SEPARATED FROM THE CATHETER. THE REPORTER STATED THAT THIS EVENT OCCURRED WITH A VERY TIGHT AORTIC BIFURCATION WHILE USING A CONTRALATERAL APPROACH. THE BALLOON WAS SUCCESSFULLY ADVANCED TO THE TARGET SITE AND INFLATED. IT WAS USED TO ANGIOPLASTY THE SUPERFICIAL FEMORAL ARTERY (SFA) AND DISTAL COMMON FEMORAL ARTERY. WHEN TRYING TO REMOVE THE BALLOON ACROSS THE BIFURCATION, RESISTANCE WAS FELT. IT WAS STATED THAT AS THE CATHETER WAS REMOVED, THE BALLOON APPEARED TO HAVE STRETCHED AND WAS TORN AS A RESULT OF THE STRETCHING. WHEN THE CATHETER WAS REMOVED, IT WAS NOTED THAT THE BALLOON WAS NOT ON THE CATHETER. WHEN THE WIRE WAS REMOVED, THE BALLOON MATERIAL WAS ON THE WIRE. THE CUSTOMER REPORTED THAT THE WIRE WAS A NON-COOK PRODUCT. THE INFLATION PRESSURE USED WAS 12 ATM. THE CONTRAST TO SALINE MIXTURE WAS OMNIPAQUE 30/70. IT WAS UNSURE IF A CLOCKWISE ROTATION WAS USED DURING CATHETER WITHDRAWAL. THE REPORTER STATED THAT ONCE DEFLATED, THE BA
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6647499 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page