Advance G52368Recalls & reported problems
Cook Incorporated · Advance, 35LP Low Profile PTA Balloon Dilatation Catheter · Class 2
All models of Advance (206)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10827002523682), received between Aug 31, 2022 and Aug 31, 2022 — classified as 1 death.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Material Rupture1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathAug 31, 2022Break; Material Rupture; Break; Material Rupture
AS REPORTED, DURING AN ANGIOGRAM OF THE AORTA WITH BILATERAL LOWER EXTREMITY RUNOFF, AN ADVANCE 35 LP LOW PROFILE BALLOON CATHETER RUPTURED UNDER NOMINAL PRESSURE AND SEPARATED. ANOTHER MANUFACTURER'S 6 FRENCH SHEATH WAS USED, WHICH WAS THEN UPSIZED TO A 7 FRENCH SHEATH. ANOTHER MANUFACTURER'S INFLATION DEVICE WAS USED TO INFLATE THE BALLOON TO EIGHT ATMOSPHERES TWO TIMES, FOR THIRTY SECONDS EACH, WITHIN THE RIGHT COMMON ILIAC ARTERY. THE ILIAC ARTERIES WERE REPORTEDLY CALCIFIED, AND THE GROINS WERE SCARRED FROM PREVIOUS SURGICAL PROCEDURES. AFTER THE BALLOON RUPTURED, THE USER ATTEMPTED TO REMOVE THE BALLOON BY ITSELF, THROUGH THE SHEATH. REPORTEDLY, SEVERAL SHEATH-RELATED MANEUVERS WERE MADE IN AN ATTEMPT TO FULLY COLLAPSE THE BALLOON INTO THE SHEATH; HOWEVER, THIS WAS NOT SUCCESSFUL, AND THE USER ATTEMPTED TO PULL THE BALLOON OUT DIRECTLY AND THE TIP OF THE BALLOON/CATHETER SEPARATED. THE DISTAL TIP OF THE DEVICE REMAINED IN THE PATIENT, AND THE DISTAL BALLOON MARKER WAS NOTED AT THE LEVEL OF THE LEFT FEMORAL ACCESS SITE. NUMEROUS MANEUVERS WERE PERFORMED TO UPSIZE THE SHEATH IN THE LEFT GROIN TO AN 8 FRENCH SYSTEM TO SNARE THE SEPARATED PORTION OF THE BALLOON/CATHETER AND RETRA
Patient problems: Foreign Body In Patient
MAUDE report 15328423 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page