Cantata G54530Recalls & reported problems
Cook Incorporated · Cantata, 2.5 Microcatheter · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10827002545301), received between Mar 31, 2017 and Sep 17, 2018 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Leak/Splash” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Leak/Splash1
- Material Separation1
Patient problems
- No Known Impact Or Consequence To Patient1
- No Patient Involvement1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 17, 2018Material Separation; Material Separation
IT WAS REPORTED THAT A CANTATA 2.5 SUPERSELECTIVE MICROCATHETER WAS TO BE USED DURING AN UNKNOWN PROCEDURE. THE DEVICE WAS FLUSHED DURING PRE-OPERATIONAL PREPARATION AND IT WAS NOTED THAT THE HUB HAD SEPARATED FROM THE CATHETER PRIOR TO USE. A LIKE DEVICE WAS OPENED AND USED SUCCESSFULLY TO COMPLETE THE PROCEDURE.
Patient problems: No Patient Involvement
MAUDE report 7882858 ↗MalfunctionMar 31, 2017Leak/Splash; Leak/Splash
INTERNATIONAL CUSTOMER REPORTED THAT THE CANTATA SUPERSELECTIVE MICROCATHETER WAS INTENDED FOR USE IN AN UNSPECIFIED INDICATION. CUSTOMER REPORTED THAT NORMAL SALINE DRIPPED OUT FROM THE HUB WHILE THE PHYSICIANS WAS FLUSHING THE DEVICE. NO FURTHER EVENT OR PATIENT RELATED INFORMATION WAS PROVIDED. THERE ARE NO REPORTS OF ANY ADVERSE PATIENT CONSEQUENCES. IT IS OPINED THAT THE PHYSICIAN OBTAINED AN UNSPECIFIED REPLACEMENT DEVICE.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6450185 ↗
FDA clearance and classification
The FDA regulates product code KRA (catheter, continuous flush) under 21 CFR 870.1210 as a Class II device. 21 CFR 870.1210 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Cantata G54530
Has the Cantata G54530 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10827002545301), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Cantata G54530?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between Mar 31, 2017 and Sep 17, 2018. In those reports, the most common specific device problems are “Leak/Splash” (1) and “Material Separation” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Cantata G54530?
None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Cantata G54530, and is it still sold?
The FDA's device database lists Cook Incorporated as the company responsible for it (brand Cantata, model G54530). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Catheter, continuous flush devices
- PROWLER SELECT 606-S255XMedos International Sàrl · Catheter, continuous flush2 deaths973 reports
- PhenomTM 27 Catheter FG15150-0615-1SMicro Therapeutics, Inc. · Catheter, continuous flush2 deaths139 reports
- MarathonTM 105-5056Micro Therapeutics, Inc. · Catheter, continuous flush124 reports
- Renegade™ HI-FLO™ Kit M001183020Boston Scientific Corporation · Catheter, continuous flush109 reports
- MarksmanTM FA-55150-1030Micro Therapeutics, Inc. · Catheter, continuous flush109 reports
- EkoSonic® 6779-002Boston Scientific Corporation · Catheter, Continuous Flush1 recall4 deaths55 reports
- Chameleon CH08-40-75USMozarc Medical US LLC · Catheter, continuous flush2 recalls4 reports
- RebarTM 105-5081-153Micro Therapeutics, Inc. · Catheter, continuous flush2 deaths102 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page