Cantata G54536Recalls & reported problems
Cook Incorporated · Cantata, 2.8 Microcatheter · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10827002545363), received between May 5, 2017 and May 5, 2017 — classified as 1 malfunction.
The most frequently reported specific device problem is “Leak/Splash” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Leak/Splash1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 5, 2017Leak/Splash; Leak/Splash
INTERNATIONAL CUSTOMER REPORTED THAT A PATIENT WAS UNDERGOING PLACEMENT OF A CANTATA 2.8 SUPERSELECTIVE MICROCATHETER FOR AN UNSPECIFIED INDICATION. THE PHYSICIAN WAS USING A COMPETITORS' GUIDE WIRE WITHIN THE CATHETER DURING PLACEMENT. THE PHYSICIAN ATTEMPTED TO FLUSH THE CATHETER WITH THE GUIDE WIRE IN PLACE TO VERIFY PROPER CATHETER TIP PLACEMENT; NO FLUID CAME OUT OF THE TIP. THE PHYSICIAN THEN REMOVED THE CATHETER AND ATTEMPTED TO FLUSH THE DEVICE. IT WAS REPORTED THAT FLUID WENT OUT OF A HOLE ON THE SIDE OF THE CATHETER. THE CUSTOMER OPINES THAT THE "CATHETER HAS BEEN HOLED BY THE GUIDE WIRE." THERE ARE NO REPORTED ADVERSE PATIENT CONSEQUENCES RELATED TO THIS EVENT. THE DEVICE IS AVAILABLE FOR EVALUATION, HOWEVER IT HAS NOT BEEN RETURNED TO THE MANUFACTURER AS OF THE DATE OF THIS REPORT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6547003 ↗
Other Catheter, continuous flush devices
- PROWLER SELECT 606-S255XMedos International Sàrl · Catheter, continuous flush2 deaths980 reports
- PhenomTM 27 Catheter FG15150-0615-1SMicro Therapeutics, Inc. · Catheter, continuous flush2 deaths139 reports
- MarathonTM 105-5056Micro Therapeutics, Inc. · Catheter, continuous flush124 reports
- Renegade™ HI-FLO™ Kit M001183020Boston Scientific Corporation · Catheter, continuous flush109 reports
- MarksmanTM FA-55150-1030Micro Therapeutics, Inc. · Catheter, continuous flush109 reports
- EkoSonic® 6779-002Boston Scientific Corporation · Catheter, Continuous Flush1 recall4 deaths56 reports
- Chameleon CH08-40-75USMozarc Medical US LLC · Catheter, continuous flush2 recalls4 reports
- RebarTM 105-5081-153Micro Therapeutics, Inc. · Catheter, continuous flush2 deaths102 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.