Zenith G55194Recalls & reported problems
Cook Incorporated · Zenith, AAA Endovascular Graft Converter · Class 3 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10827002551944), received between Jul 17, 2017 and Jul 17, 2017 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Defective Device” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Defective Device2
Patient problems
- No Known Impact Or Consequence To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 17, 2017Defective Device; Defective Device
IT WAS REPORTED THAT DURING AN ENDOVASCULAR ANEURYSM REPAIR (EVAR) WITH RIGHT AND LEFT FEMORAL ACCESS USING A ZENITH WITH Z-TRAK AAA ENDOVASCULAR GRAFT CONVERTER, THE SUTURES OF THE TOP STENT WERE LOOSE AND THAT THE GRAFT WAS SLIDING DOWN THE STENT STRUT. THE EVAR WAS SCHEDULED TO REPAIR ANEURYSM ABOVE PREVIOUS OPEN AORTIC ANEURYSM REPAIR. THE PLAN WAS TO FLIP A CONVERTOR TO SEAL IN OPEN GRAFT IN THE ABDOMINAL AORTA. WE OPENED THE GRAFT ON THE BACK TABLE AND THE PLAN WAS TO FLIP IT AND PUT IT BACK IN THE SHEATH. WHEN WE FIRST OPENED THE FIRST ESC (LOT 5349451), IT SHOWED THAT THE SUTURES OF THE TOP STENT WERE LOOSE AND THAT THE GRAFT WAS SLIDING DOWN THE STENT STRUT (CAPTURED IN MEDWATCH WITH NUMBER 1820334-2017-01510). THE GRAFT WAS THOUGHT TO BE EXPIRING SOON AND PERHAPS THAT WAS THE REASON. ANOTHER GRAFT WAS THEN OPENED THAT WITH AN EXPIRATION DATE IN 2018 (LOT 6264283) AND THE SAME PROBLEM OCCURRED (CAPTURED IN MEDWATCH WITH NUMBER 1820334-2017-01511). THE DOCTOR DECIDED TO ADD SUTURES TO FIX THE PROBLEM BEFORE PUTTING IT BACK IN THE SHEATH. ISSUE WAS THAT THE LOOSE SUTURES AFFECTED THE SEAL STENT AND THEREFORE AFFECTED SEAL ZONE BY DECREASING THE ACCURACY OF THE SEAL. THE PATI
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6717088 ↗MalfunctionJul 17, 2017Defective Device; Defective Device
IT WAS REPORTED THAT DURING AN ENDOVASCULAR ANEURYSM REPAIR (EVAR) WITH RIGHT AND LEFT FEMORAL ACCESS USING A ZENITH WITH Z-TRAK AAA ENDOVASCULAR GRAFT CONVERTER, THE SUTURES OF THE TOP STENT WERE LOOSE AND THAT THE GRAFT WAS SLIDING DOWN THE STENT STRUT. THE EVAR WAS SCHEDULED TO REPAIR ANEURYSM ABOVE PREVIOUS OPEN AORTIC ANEURYSM REPAIR. THE PLAN WAS TO FLIP A CONVERTOR TO SEAL IN OPEN GRAFT IN THE ABDOMINAL AORTA. WE OPENED THE GRAFT ON THE BACK TABLE AND THE PLAN WAS TO FLIP IT AND PUT IT BACK IN THE SHEATH. WHEN WE FIRST OPENED THE FIRST ESC (LOT 5349451), IT SHOWED THAT THE SUTURES OF THE TOP STENT WERE LOOSE AND THAT THE GRAFT WAS SLIDING DOWN THE STENT STRUT (CAPTURED IN MEDWATCH WITH NUMBER 1820334-2017-01510). THE GRAFT WAS THOUGHT TO BE EXPIRING SOON AND PERHAPS THAT WAS THE REASON. ANOTHER GRAFT WAS THEN OPENED THAT WITH AN EXPIRATION DATE IN 2018 (LOT 6264283) AND THE SAME PROBLEM OCCURRED (CAPTURED IN MEDWATCH WITH NUMBER 1820334-2017-01511). THE DOCTOR DECIDED TO ADD SUTURES TO FIX THE PROBLEM BEFORE PUTTING IT BACK IN THE SHEATH. ISSUE WAS THAT THE LOOSE SUTURES AFFECTED THE SEAL STENT AND THEREFORE AFFECTED SEAL ZONE BY DECREASING THE ACCURACY OF THE SEAL. THE PATI
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6717065 ↗
Other SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page