Skip to content

Formula 418 G56609Recalls & reported problems

Cook Incorporated · Formula 418, Renal Balloon-Expandable Stent · Class 3 · Implant

All models of Formula 418 (12)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10827002566092), received between Oct 25, 2024 and Oct 25, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Premature Separation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Premature Separation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 25, 2024Premature Separation; Premature Separation

    AS REPORTED, DURING A PROCEDURE INVOLVING IMPLANTATION OF A STENT WITHIN THE RENAL ARTERY, A FORMULA 418 RENAL BALLOON-EXPANDABLE STENT SLIPPED OFF THE BALLOON. THE DEVICE WAS LOADED THROUGH ANOTHER MANUFACTURER¿S 6-FRENCH GUIDE AND ADVANCED NEAR THE RENAL ARTERY. THE INSERTION TOOL WAS NOT USED TO INSERT THE DEVICE INTO THE GUIDE/SHEATH; HOWEVER, A LARGE TUOHY-BORST ADAPTER WAS USED DURING INSERTION. THE STENT WAS NOT MOISTENED WITH HEPARINIZED SALINE AND GAUZE WAS NOT USED TO MOISTEN THE STENT. THE REFERENCE VESSEL DIAMETER WAS APPROXIMATELY SIX MILLIMETERS, AND THE LESION WAS LESS THAN FIVE CENTIMETERS LONG. THE ANATOMY WAS TORTUOUS, AND THE LESION WAS CALCIFIED AND NINETY PERCENT STENOSED. AS THE USER ATTEMPTED TO MANEUVER THE STENT THROUGH THE STENOSED LESION, THE STENT SLIPPED OFF THE BALLOON. THE PHYSICIAN WAS ABLE TO QUICKLY CAPTURE AND RETRIEVE THE STENT USING ANOTHER MANUFACTURER¿S BALLOON, AND THE STENT WAS THEN DEPLOYED AND IMPLANTED IN THE RENAL ARTERY AS INTENDED. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES OR EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20537816 ↗

Other STENT, RENAL devices

All STENT, RENAL devices →