The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10827002569758), received between Sep 10, 2020 and Sep 10, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Premature Separation” (1 report).
1 other recall cover devices cleared under the same FDA submission (P100028); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Premature Separation1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 10, 2020Premature Separation; Premature Separation
DESCRIPTION OF EVENT ACCORDING TO INITIAL REPORTER: WHEN THE DOCTOR WENT TO DEPLOY THE STENT, THE STENT STARTED TO FLARE. ONE END STARTED TO DEPLOY BEFORE THE BALLOON WAS FULLY INFLATED. WHEN THAT HAPPENED, THE STENT MOVED PAST THE ILIAC AND INTO THE AORTA WHILE PARTIALLY DEPLOYED. THEY USED 2 TWO ADDITIONAL COOK BALLOONS (G50328 AND G50319) TO MOVE THE STENT BACK TO THE CORRECT POSITION AND PLACE IT SUCCESSFULLY. THE DOCTOR SAID THE STENT LOCATION WAS PERFECT AT THE END. THIS IS A RENAL STENT THAT HE WAS USING IN THE ILIAC. PATIENT OUTCOME: THE COMPLAINANT DID NOT REPORT ANY ADVERSE EFFECTS TO THE PATIENT DUE TO THIS OCCURRENCE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10513428 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P100028. One submission often covers many models, so check the product and lot details in each record.
- Z-1940-2020 · Apr 15, 2020 · TerminatedFormula 418 Renal Balloon-Expandable Stent, RPN FOR418-18-80-6-12, Order Number (GPN) G56611 Balloon-expandable stent made of 316L stainless steel with a slotted tube configuratio
Other STENT, RENAL devices
- Herculink Elite 1011487-15Abbott Vascular Inc. · STENT, RENAL27 reports
- Express® SD Renal/Biliary H74937912618150Boston Scientific Corporation · STENT, RENAL27 reports
- Herculink Elite 1011487-12Abbott Vascular Inc. · STENT, RENAL24 reports
- Herculink Elite 1011493-18Abbott Vascular Inc. · STENT, RENAL1 death16 reports
- Herculink Elite 1011487-18Abbott Vascular Inc. · STENT, RENAL13 reports
- Herculink Elite 1011499-18Abbott Vascular Inc. · STENT, RENAL13 reports
- Herculink Elite 1011499-15Abbott Vascular Inc. · STENT, RENAL12 reports
- Herculink Elite 1011493-12Abbott Vascular Inc. · STENT, RENAL11 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page