TRAPLINER IPN913564Recalls & reported problems
Teleflex Incorporated · TrapLiner 8F · Class 2
All models of TRAPLINER (6)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10841156100568), received between Aug 23, 2023 and Nov 7, 2025 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Material Separation” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Material Separation4
Patient problems
- No Clinical Signs, Symptoms or Conditions4
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 7, 2025Material Separation; Material Separation
IT WAS REPORTED THAT: "THE TRAPLINER WAS ADVANCED TOO FAR EXPOSING THE COLLAR OUTSIDE OF THE GUIDE CATHETER. WHEN REALIZED PHYSICIAN ATTEMPTED TO CORRECT AND PULL BACK INTO THE GUIDE CATHETER CAUSING THE TRAPLINER TO BREAK INTO PIECES AT THE FLEX POINT WHILE CROSSING THE VD-OM. CATHETER WAS RETRIEVED SUCCESSFULLY WITH A GUIDELINER AND BALLOON AND PROCEDURE WAS COMPLETED."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23494576 ↗MalfunctionMay 9, 2025Material Separation; Material Separation
IT WAS REPORTED THAT: "UPON REMOVAL FROM THE HOOP, THE TRAPLINER WAS FOUND TO BE IN TWO SEPARATE PIECES. ANOTHER TRAPLINER WAS USED SUCCESSFULLY." THE ISSUE WAS IDENTIFIED PRIOR TO USE; THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21992540 ↗MalfunctionApr 30, 2024Material Separation; Material Separation
IT WAS REPORTED THAT: DURING A PROCEDURE, THE RT PREPPING THE TRAPLINER FLUSHED THE DEVICE. THE RT NOTED THAT THE TIP WAS SEPARATED. THE DEVICE WAS NEVER INSERTED INTO THE PATIENT. IT WAS SET ASIDE AND ANOTHER 8F TRAPLINER WAS PREPPED AND USED TO COMPLETE THE PROCEDURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19211327 ↗MalfunctionAug 23, 2023Material Separation; Material Separation
IT WAS REPORTED THAT: A PIECE OF TRAPLINER BROKE OFF WHEN TECH WAS PREPPING IT. NOT USED ON A PATIENT. NO ADDITIONAL INFORMATION RECIEVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17601453 ↗
Other Catheter, percutaneous devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page