Skip to content

TURNPIKE IPN931271Recalls & reported problems

Teleflex Incorporated · Turnpike Spiral, 135cm, TCT · Class 2

All models of TURNPIKE (18)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10841156103927), received between Dec 3, 2025 and Feb 9, 2026 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Difficult to Advance” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Advance1
  • Material Separation1
  • Physical Resistance/Sticking1

Patient problems

  • Foreign Body In Patient1
  • Perforation1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 9, 2026Material Separation

    IT WAS REPORTED THAT: "THE TIP OF THE CATHETER DISCONNECTED AND STAYED INSIDE THE PATIENT. THE TIP REMAINS IN THE PATIENT. THE PATIENT MUST NOW TAKE BLOOD THINNERS OR ANTITHROMBOTIC MEDICATION. THE PATIENT IS REPORTED AS "FINE".

    Patient problems: Foreign Body In Patient

    MAUDE report 24290020 ↗
  • MalfunctionDec 3, 2025Difficult to Advance; Physical Resistance/Sticking; Difficult to Advance; Physical Resistance/Sticking

    IT WAS REPORTED THAT "TP SPIRAL USED WITH A GUIDEWIRE IN A CTO / COMPLEX CASE - SO ARTERIES NEEDED SOME WORK. DR SUSPECTED THERE WAS AN ISSUE WITH THE HUB. THE GUIDEWIRE GOT STUCK AND COULD NOT BE MOVED FORWARD THROUGH THE MICROCATHETER. THE DR TRIED TO MOVE IT, BUT IT LED TO A PERFORATION. PATIENT IS FINE. DR NOT SURE WHETHER THE TP SPIRAL WAS THE ISSUE BUT WANTED TO INVESTIGATE."

    Patient problems: Perforation

    MAUDE report 23704268 ↗

Other Catheter, percutaneous devices

All Catheter, percutaneous devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page