CHOCOLATE IPN914595Recalls & reported problems
Teleflex Incorporated · Chocolate XD Hydro Coated 140cm 3.0x10 · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10841156105464), received between Sep 13, 2022 and Sep 13, 2022 — classified as 1 death.
The most frequently reported specific device problem is “Entrapment of Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Entrapment of Device1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathSep 13, 2022Entrapment of Device; Entrapment of Device
AS REPORTED: THE CHOCOLATE XD BALLOON WAS INFLATED IN THE OM BRANCH OF THE CIRCUMFLEX ARTERY TO DILATE A CALCIFIED IN-STENT RESTENOSIS. THE BALLOON WAS DEFLATED AND UPON REMOVAL, THE CAGE WAS LODGED IN THE VESSEL. WHEN IT WAS PULLED BACK THE BALLOON AND NITINOL CAGE WERE SEPARATED FROM THE SHAFT. EVERY INTERVENTIONAL ATTEMPT WAS MADE TO REMOVE THE DEVICE (SNARES, ASPIRATION, GUIDE EXTENSION). THE DEVICE WAS UNABLE TO BE RETRIEVED FROM THE VESSEL. THE PATIENT BECAME UNSTABLE AND REQUIRED ECMO SUPPORT. ADDITIONAL INFORMATION ON 06 SEPT 2022: THE PATIENT IS STILL ON ECMO, INTUBATED AND IN THE ICU. PATIENT'S CURRENT CONDITION IS REPORTED AS SERIOUS. THE PATIENT RECEIVED CPR AND WAS INTUBATED AND VENTILATED DUE TO THIS EVENT.
Patient problems: Foreign Body In Patient
MAUDE report 15411155 ↗
Other Catheters, transluminal coronary angioplasty, percutaneous devices
- MINI TREK™ 1012270-15Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous223 reports
- Maverick²™ H7493892815200Boston Scientific Corporation · Catheters, transluminal coronary angioplasty, percutaneous1 death203 reports
- MINI TREK™ 1012270-12Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous162 reports
- Maverick²™ H7493892820200Boston Scientific Corporation · Catheters, transluminal coronary angioplasty, percutaneous161 reports
- NC TREK 1012454-08Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous2 recalls59 reports
- TREK™ 1012272-15Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous2 deaths158 reports
- NC TREK 1012453-12Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous1 recall84 reports
- NC TREK 1012453-15Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous1 recall1 death83 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page