Summary

The FDA's MAUDE database contains 21 adverse event reports that list this exact device (DI 10841307100942), received between Sep 27, 2019 and Aug 19, 2026 — classified as 19 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Failure to Osseointegrate” (10 reports).

4 other recalls cover devices cleared under the same FDA submission (K061319); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 2 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate10
  • Loss of Osseointegration3
  • Osseointegration Problem3
  • Positioning Failure2
  • Adverse Event Without Identified Device or Use Problem1
  • Positioning Problem1
  • Separation Failure1

Patient problems

  • Failure of Implant17
  • Unspecified Infection4
  • Inadequate Osseointegration3
  • No Clinical Signs, Symptoms or Conditions3
  • No Consequences Or Impact To Patient3
  • Inflammation2
  • Osteopenia/ Osteoporosis2
  • Pain2

Recent adverse event reports

The 21 most recent of 21 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 19, 2026Failure to Osseointegrate

    Failure to osseointegrate.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 50333338 ↗
  • InjuryFeb 3, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24253568 ↗
  • InjuryJan 6, 2026Failure to Osseointegrate

    LACK OF STABILITY DURING PLACEMENT.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23982574 ↗
  • InjuryNov 3, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant

    MAUDE report 23449236 ↗
  • InjuryNov 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    FRACTURE OF BONE.

    Patient problems: Bone Fracture(s); Unspecified Infection

    MAUDE report 23448999 ↗
  • MalfunctionDec 21, 2022Separation Failure; Separation Failure

    PER COMPLAINT (B)(4), DURING CLINICAL PROCEDURE,COMPONENTS COULD NOT BE SEPERATED.

    Patient problems: Failure of Implant

    MAUDE report 16020576 ↗
  • InjurySep 1, 2022Positioning Failure; Positioning Failure

    PER COMPLAINT (B)(4), DURING CLINICAL PROCEDURE, PATIENT EXPERIENCED LACK OF PRIMARY STABILITY.

    Patient problems: Failure of Implant

    MAUDE report 15336554 ↗
  • MalfunctionMar 7, 2022Osseointegration Problem; Osseointegration Problem

    PER COMPLAINT (B)(4), DURING CLINICAL PROCEDURE, COMPONENTS COULD NOT BE SEPARATED.

    Patient problems: Failure of Implant

    MAUDE report 13685345 ↗
  • InjuryFeb 25, 2022Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant

    MAUDE report 13599023 ↗
  • InjuryFeb 14, 2022Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Pain; Unspecified Infection

    MAUDE report 13530025 ↗
  • InjurySep 21, 2021Positioning Failure; Positioning Failure

    PER COMPLAINT (B)(4), DURING CLINICAL PROCEDURE, PATIENT EXPERIENCED LACK OF PRIMARY STABILITY.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 12506351 ↗
  • InjuryDec 29, 2020Loss of Osseointegration; Loss of Osseointegration

    PER (B)(4), DURING CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO INTEGRATE.

    Patient problems: Failure of Implant; Inflammation

    MAUDE report 11087783 ↗
  • InjuryOct 7, 2020Osseointegration Problem; Osseointegration Problem

    PER COMPLAINT (B)(4), DURING CLINICAL PROCEDURE, PATIENT EXPERIENCED LACK OF PRIMARY STABILITY.

    Patient problems: Failure of Implant

    MAUDE report 10640131 ↗
  • InjuryJul 1, 2020Failure to Osseointegrate; Failure to Osseointegrate

    AS PER COMPLAINT (B)(4) DURING A CLINICAL PROCEDURE A DENTAL IMPLANT DISPLAYED A FAILURE OF OSSEOINTEGRATION AND THE IMPLANT WAS EXPLANTED.

    Patient problems: Failure of Implant; No Consequences Or Impact To Patient

    MAUDE report 10218032 ↗
  • InjuryMar 27, 2020Failure to Osseointegrate; Failure to Osseointegrate

    PER (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Fibrosis

    MAUDE report 9889660 ↗
  • InjuryMar 10, 2020Loss of Osseointegration; Loss of Osseointegration

    PER COMPLAINT (B)(4), DURING LABORATORY PROCEDURE, PATIENT EXPERIENCED LOSS OR FAILURE OF IMPLANT TO INTEGRATE.

    Patient problems: Failure of Implant; Pain

    MAUDE report 9809696 ↗
  • InjuryFeb 14, 2020Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED LOSS OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Inflammation; Unspecified Infection

    MAUDE report 9710634 ↗
  • InjuryFeb 7, 2020Osseointegration Problem; Osseointegration Problem

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; No Consequences Or Impact To Patient

    MAUDE report 9680227 ↗
  • InjuryJan 14, 2020Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4)., PATIENT EXPERIENCED LOSS OR FAILURE OF IMPLANT TO INTEGRATE.

    Patient problems: Failure of Implant; Osteopenia/ Osteoporosis

    MAUDE report 9585531 ↗
  • InjuryJan 14, 2020Positioning Problem; Positioning Problem

    PER COMPLAINT (B)(4), PATIENT EXPERIENCED LACK OF PRIMARY STABILITY.

    Patient problems: Failure of Implant; No Consequences Or Impact To Patient

    MAUDE report 9585528 ↗
  • InjurySep 27, 2019Loss of Osseointegration; Loss of Osseointegration

    PER COMPLAINT (B)(4), PATIENT EXPERIENCED LOSS OR FAILURE OF IMPLANT TO INTEGRATE.

    Patient problems: Failure of Implant; Osteopenia/ Osteoporosis

    MAUDE report 9129234 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K061319. One submission often covers many models, so check the product and lot details in each record.

  • Z-0010-2020 · Aug 7, 2018 · Terminated
    ImplantDirect simply RePlant Implant, size 4.3mmD x 13mmL, 4.3mmD Platform, REF 604313U, Rx, Sterile. The firm name on the label is Implant Direct Sybron Manufacturing LLC, Thousa
  • Z-2376-2018 · May 18, 2018 · Terminated
    REPLANT 5.0mmD ABUTMENT, Part number 6050-52-60
  • Z-2125-2017 · May 2, 2017 · Terminated
    Legacy Full Contour Laboratory Abutment: 3.5mmD Platform/5.5mmD
  • Z-2320-2016 · Jul 5, 2016 · Terminated
    RePlant Angled Abutment Part Number 6050-52-60

Other Implant, Endosseous, Root-Form devices