Skip to content

Legacy™2 Implant 825710Recalls & reported problems

Implant Direct Sybron Manufacturing LLC · Ø5.7 x 10 Platform 5.7mmD · Class 2 · Implant

All models of Legacy2 Implant (78)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Implant Direct Legacy 2 dental implant is a root-form implant placed in the jawbone to support a replacement tooth. Of the 161 reports, many describe implants that did not fuse with the bone or were lost, and some mention inflammation or infection. The reports include no deaths and 159 injuries. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
162
Deaths reported
0
Injuries reported
160
Recalls naming it
0

Summary

The FDA's MAUDE database contains 162 adverse event reports that list this exact device (DI 10841307101499), received between May 8, 2018 and Sep 17, 2026 — classified as 160 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Failure to Osseointegrate” (81 reports).

2 other recalls cover devices cleared under the same FDA submission (K192221); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 3 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 2 reportsApr 2024: 1 reportsMay 2024: 2 reportsJun 2024: 2 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 4 reportsNov 2024: 3 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 4 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 3 reportsDec 2025: 4 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 3 reportsApr 2026: 1 reportsMay 2026: 2 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate81
  • Loss of Osseointegration23
  • Osseointegration Problem22
  • Positioning Failure17
  • Positioning Problem8
  • Adverse Event Without Identified Device or Use Problem5
  • Malposition of Device3
  • Labelling, Instructions for Use or Training Problem2

Patient problems

  • Failure of Implant135
  • Inflammation29
  • Unspecified Infection27
  • Osteopenia/ Osteoporosis24
  • No Clinical Signs, Symptoms or Conditions19
  • No Consequences Or Impact To Patient17
  • Inadequate Osseointegration16
  • Pain14

Recent adverse event reports

The 25 most recent of 162 reports, in the reporter's own words as published by the FDA.

  • InjurySep 17, 2026Positioning Failure

    Lack of Primary Stability.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50805277 ↗
  • InjuryAug 25, 2026Positioning Failure

    Lack of stability during placement.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 50440186 ↗
  • InjuryMay 29, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; Inflammation

    MAUDE report 25340405 ↗
  • InjuryMay 20, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; Unspecified Infection

    MAUDE report 25234284 ↗
  • InjuryApr 29, 2026Adverse Event Without Identified Device or Use Problem

    TRAUMA / CLINICAL COMPLICATION ONLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25032102 ↗
  • InjuryMar 19, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24644511 ↗
  • InjuryMar 14, 2026Failure to Osseointegrate; Osseointegration Problem

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24600441 ↗
  • InjuryMar 6, 2026Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24539289 ↗
  • InjuryDec 19, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; Inflammation

    MAUDE report 23851640 ↗
  • InjuryDec 4, 2025Malposition of Device; Malposition of Device

    LACK OF PRIMARY STABILITY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23720869 ↗
  • InjuryDec 4, 2025Malposition of Device; Malposition of Device

    LACK OF PRIMARY STABILITY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23720808 ↗
  • InjuryDec 2, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23694466 ↗
  • InjuryNov 6, 2025Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information

    LACK OF STABILITY DURING PLACEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23483770 ↗
  • InjuryNov 6, 2025Migration; Migration

    PART MIGRATES.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23483678 ↗
  • InjuryNov 3, 2025Labelling, Instructions for Use or Training Problem; Adverse Event Without Identified Device or Use Problem; Labelling, Instructions for Use or Training Problem; Adverse Event Without Identified Device or Use Problem

    USABILITY - WRONG PART USED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23449345 ↗
  • InjuryApr 1, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION

    Patient problems: Inadequate Osseointegration; Osteopenia/ Osteoporosis; Unspecified Infection

    MAUDE report 21746809 ↗
  • InjuryMar 27, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Inadequate Osseointegration; Unspecified Infection

    MAUDE report 21714038 ↗
  • InjuryMar 11, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 21578354 ↗
  • InjuryMar 5, 2025Positioning Failure; Labelling, Instructions for Use or Training Problem; Positioning Failure; Labelling, Instructions for Use or Training Problem

    USABILITY - WRONG PART USED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21530265 ↗
  • InjuryMar 4, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Inflammation; Osteopenia/ Osteoporosis; Unspecified Infection

    MAUDE report 21519128 ↗
  • InjuryJan 16, 2025Osseointegration Problem; Osseointegration Problem

    LOSS OF OSSEOINTEGRATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21173559 ↗
  • InjuryNov 18, 2024Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 20713299 ↗
  • InjuryNov 12, 2024Failure to Osseointegrate; Failure to Osseointegrate

    PRIMARY STABILITY COULDN¿T BE ACHIEVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20669661 ↗
  • InjuryNov 8, 2024Loss of Osseointegration; Loss of Osseointegration

    PRODUCT COMPL: LOSS OF OSSEOINTEGRATION.

    Patient problems: Abscess; Failure of Implant

    MAUDE report 20636922 ↗
  • InjuryOct 24, 2024Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 20529102 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K192221. One submission often covers many models, so check the product and lot details in each record.

  • Z-0197-2022 · Sep 23, 2021 · Open, Classified
    ImplantDirect, REF 834711, Legacy 2 Implant 4.7mmD x 11.5mmL, 4.5mmD Platform,
  • Z-0198-2022 · Sep 23, 2021 · Open, Classified
    ImplantDirect, REF 834713, Legacy 2 Implant 4.7mmD x 13mmL, 4.5mmD Platform,

Other Implant, Endosseous, Root-Form devices

All Implant, Endosseous, Root-Form devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page