Adverse event reports
5
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10841307102335), received between Mar 1, 2019 and Nov 18, 2024 — classified as 4 injuries, 1 malfunction.

The most frequently reported specific device problem is “Failure to Osseointegrate” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate3
  • Fracture1
  • Material Deformation1
  • Separation Failure1

Patient problems

  • Failure of Implant4
  • Fibrosis1
  • Granuloma1
  • Inadequate Osseointegration1
  • Inflammation1
  • No Clinical Signs, Symptoms or Conditions1
  • No Consequences Or Impact To Patient1
  • Wound Dehiscence1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 18, 2024Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 20717567 ↗
  • InjuryJun 30, 2023Fracture; Fracture

    PER COMPLAINT (B)(4), DURING CLINICAL PROCEDURE, BONE FRACTURE WAS OBSERVED.

    Patient problems: Failure of Implant

    MAUDE report 17237295 ↗
  • InjuryOct 18, 2022Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Fibrosis; Granuloma; Inflammation; Wound Dehiscence

    MAUDE report 15626906 ↗
  • InjuryNov 27, 2020Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED LOSS OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant

    MAUDE report 10912924 ↗
  • MalfunctionMar 1, 2019Separation Failure; Material Deformation; Separation Failure; Material Deformation

    PER COMPLAINT (B)(4), THE COPING WAS UNABLE TO BE REMOVED DURING DENTAL IMPLANT PLACEMENT. THE COPING STRIPPED AND THE DRIVER WAS UNABLE TO BE PLACED. THE IMPLANT WAS EXPLANTED ON THE SAME DAY. NO ADVERSE CONSEQUENCES WERE REPORTED.

    Patient problems: Failure of Implant; No Consequences Or Impact To Patient

    MAUDE report 8383838 ↗