Legacy™3 Implant 865211Recalls & reported problems
Implant Direct Sybron Manufacturing LLC · 5.2mmD x 11.5mmL, 4.5mmD Platform · Class 2 · Implant
All models of Legacy3 Implant (75)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10841307102649), received between Dec 4, 2018 and Aug 31, 2020 — classified as 4 injuries.
The most frequently reported specific device problem is “Loss of Osseointegration” (1 report).
11 other recalls cover devices cleared under the same FDA submission (K090234); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Loss of Osseointegration1
- Patient Device Interaction Problem1
- Positioning Problem1
Patient problems
- Failure of Implant4
- Pain2
- Edema1
- Inflammation1
- Nerve Damage1
- No Information1
- Osteopenia/ Osteoporosis1
- Sinus Perforation1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryAug 31, 2020Positioning Problem; Positioning Problem
AS PER COMPLAINT (B)(4) DURING A CLINICAL PROCEDURE A DENTAL IMPLANT DISPLAYED A LACK OF PRIMARY STABILITY AND THE IMPLANT WAS REMOVED. THERE WAS 1 PATIENT INVOLVED IN THIS EVENT.
Patient problems: Failure of Implant; No Information
MAUDE report 10471177 ↗InjuryOct 18, 2019Loss of Osseointegration; Loss of Osseointegration
PER COMPLAINT (B)(4), DURING POST OPERATIVE CHECK PATIENT EXPERIENCED FAILURE OF IMPLANT TO INTEGRATE.
Patient problems: Failure of Implant; Sinus Perforation
MAUDE report 9207894 ↗InjuryApr 16, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PER COMPLAINT (B)(4), A PATIENT EXPERIENCED PAIN AND INTRAORAL INFECTION. THEIR DENTAL IMPLANT WAS EXPLANTED SIX YEARS AFTER INITIAL PLACEMENT. AN EDEMA, INFLAMMATION, AND OSTEOPENIA WERE ALSO REPORTED.
Patient problems: Edema; Failure of Implant; Inflammation; Osteopenia/ Osteoporosis; Pain; Unspecified Infection
MAUDE report 8520279 ↗InjuryDec 4, 2018Patient Device Interaction Problem; Patient Device Interaction Problem
PER COMPLAINT (B)(4), A PATIENT'S DENTAL IMPLANT WAS REMOVED TWO DAYS AFTER INITIAL PLACEMENT DUE TO PAIN AND POSSIBLE INFERIOR ALVEOLAR NERVE IMPINGEMENT.
Patient problems: Failure of Implant; Nerve Damage; Pain
MAUDE report 8131135 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K090234. One submission often covers many models, so check the product and lot details in each record.
- Z-1157-2020 · Oct 11, 2019 · TerminatedImplant Direct, CE 0086, REF: 855710, Legacy 3 Impant, Surface: SBM, Qty:1, Size:5.7mmD x 10mmL, 5.7mmD Platform, RxOnly, Sterile R,
- Z-1041-2020 · Oct 7, 2019 · TerminatedLegacy 3 Implant, Size: 4.2mmD x 13mmL, 3.5mmD Platform, REF: 864213
- Z-0364-2020 · Aug 9, 2019 · TerminatedImplant Direct, REF: 833708, Legacy 2 Implant, Surface: HA, 3.7mmD x 8mmL, 3.5mmD Platform, RxOnly, Sterile R, Made in USA Dental Implants
- Z-0018-2020 · Aug 8, 2018 · TerminatedImplantDirect Legacy 3 Implant, REF 855216, SBM implant assembly, 2mmD x 16mmL, 4.5mmD platform, Rx, Sterile. The mislabeled model/part number on the vial cap is 835216. The re
- Z-1167-2018 · Jan 19, 2018 · TerminatedSwishTapered Implant Intended for use in support for fixed bridgework.
- Z-0185-2018 · Oct 10, 2017 · TerminatedImplantDirect Legacy(TM) 3 Implant, 13MM L, REF 864713 This Legacy implant is a two-piece implant for one-stage or two-stage surgical procedures. These implants are intended for
- Z-0007-2018 · Jul 21, 2017 · TerminatedImplant Direct Swish Duo-Grip Healing Collar, Length: 3mm, Platform: 4.8 mm, Rx only, Sterile Dental Implant component.
- Z-1112-2017 · Dec 12, 2016 · TerminatedSwishTapered Implant
- Z-0961-2017 · Nov 28, 2016 · TerminatedGoDirect Screw-Retaining Top Part Numbers: 4500-61
- Z-1920-2018 · Nov 15, 2016 · TerminatedImplantDirect Legacy 4 Implant, 5.7mmD x 5.7mmD Platform, Part 885708, Rx, Sterile. The incorrect cap label shows part 855708, 5.7mmD Platform, 8mmL.
- Z-1267-2016 · Mar 4, 2016 · TerminatedThe Spectra-System Dental Implant 2008 system is comprised of dental implant fixtures and prosthetic devices that compose a two-piece implant system. GoDirect Implants Part Numbe
Other Implant, Endosseous, Root-Form devices
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM43,616 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM40,404 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM27,400 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,621 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLA Titanium BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,298 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM23,448 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,320 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,267 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page