Legacy™4 Implant 877013Recalls & reported problems

Implant Direct Sybron Manufacturing LLC · Ø7.0 x 13 Platform 5.7mmD · Class 2 · Implant

All models of Legacy4 Implant (58)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10841307103172), received between May 25, 2022 and Oct 3, 2022 — classified as 3 injuries.

The most frequently reported specific device problem is “Loss of Osseointegration” (2 reports).

2 other recalls cover devices cleared under the same FDA submission (K192221); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Loss of Osseointegration2
  • Osseointegration Problem1

Patient problems

  • Failure of Implant3
  • Insufficient Information2
  • Granuloma1
  • Inflammation1
  • Osteopenia/ Osteoporosis1
  • Unspecified Infection1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 3, 2022Loss of Osseointegration; Loss of Osseointegration

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Granuloma; Inflammation; Osteopenia/ Osteoporosis; Unspecified Infection

    MAUDE report 15527790 ↗
  • InjuryJun 8, 2022Loss of Osseointegration; Loss of Osseointegration

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED LOSS FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Insufficient Information

    MAUDE report 14632321 ↗
  • InjuryMay 25, 2022Osseointegration Problem; Osseointegration Problem

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED LOSS OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Insufficient Information

    MAUDE report 14497618 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K192221. One submission often covers many models, so check the product and lot details in each record.

  • Z-0197-2022 · Sep 23, 2021 · Open, Classified
    ImplantDirect, REF 834711, Legacy 2 Implant 4.7mmD x 11.5mmL, 4.5mmD Platform,
  • Z-0198-2022 · Sep 23, 2021 · Open, Classified
    ImplantDirect, REF 834713, Legacy 2 Implant 4.7mmD x 13mmL, 4.5mmD Platform,

Other Implant, Endosseous, Root-Form devices