Quick summary

This Implant Direct simply InterActive dental implant has 108 reports, no deaths and 107 injuries. Most reports describe the implant failing to bond with the jawbone, with some describing bone bonding that was lost, poor stability during placement, or an abutment that is partly visible. Many patients were reported to have implant failure, and some also had low bone density or inflammation. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
108
Deaths reported
0
Injuries reported
107
Recalls naming it
0

Summary

The FDA's MAUDE database contains 108 adverse event reports that list this exact device (DI 10841307106807), received between Jun 20, 2018 and Jul 29, 2026 — classified as 107 injuries, 1 malfunction.

The most frequently reported specific device problem is “Failure to Osseointegrate” (62 reports).

4 other recalls cover devices cleared under the same FDA submission (K130572); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 3 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 2 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 2 reportsNov 2025: 2 reportsDec 2025: 1 reportsJan 2026: 1 reportsFeb 2026: 2 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 2 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate62
  • Loss of Osseointegration20
  • Osseointegration Problem9
  • Positioning Failure5
  • Positioning Problem5
  • Fracture2
  • Adverse Event Without Identified Device or Use Problem1
  • Improper or Incorrect Procedure or Method1

Patient problems

  • Failure of Implant90
  • Osteopenia/ Osteoporosis24
  • Inflammation18
  • Inadequate Osseointegration13
  • No Clinical Signs, Symptoms or Conditions12
  • No Consequences Or Impact To Patient12
  • Pain10
  • Unspecified Infection10

Recent adverse event reports

The 25 most recent of 108 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 29, 2026Failure to Osseointegrate

    Failure to osseointegrate.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 50073918 ↗
  • InjuryJul 29, 2026Failure to Osseointegrate

    Failure to osseointegrate.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 50073658 ↗
  • InjuryJun 23, 2026Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 25600399 ↗
  • InjuryApr 9, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24835944 ↗
  • InjuryFeb 17, 2026Positioning Failure

    LACK OF STABILITY DURING PLACEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24366149 ↗
  • InjuryFeb 3, 2026Inadequacy of Device Shape and/or Size

    IMPLANT/ABUTMENT PARTIALLY VISIBLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24251656 ↗
  • InjuryJan 21, 2026Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Inadequate Osseointegration; Osteopenia/ Osteoporosis

    MAUDE report 24133156 ↗
  • InjuryDec 22, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23872637 ↗
  • InjuryNov 4, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration

    MAUDE report 23461232 ↗
  • InjuryNov 3, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23448940 ↗
  • InjuryOct 31, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; Osteopenia/ Osteoporosis; Pain

    MAUDE report 23436711 ↗
  • InjuryOct 31, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23436627 ↗
  • InjuryJan 30, 2025Positioning Failure; Positioning Failure

    LACK OF PRIMARY STABILITY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21278010 ↗
  • InjuryJan 1, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 21051441 ↗
  • InjuryDec 3, 2024Loss of Osseointegration; Loss of Osseointegration

    LOSS OF INTEGRATION.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 20836654 ↗
  • InjuryAug 7, 2024Failure to Osseointegrate; Malposition of Device; Failure to Osseointegrate; Malposition of Device

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Hypersensitivity/Allergic reaction; Inadequate Osseointegration

    MAUDE report 19930654 ↗
  • InjuryAug 7, 2024Patient Device Interaction Problem; Patient Device Interaction Problem

    CUSTOMER STATES "OTHER PRODUCT DEFICIENCIES AND TECHNICAL," CUSTOMER CLAIM INDICATES AN ALLERGIC REACTION BY THE PATIENT.

    Patient problems: Numbness; Pain

    MAUDE report 19929840 ↗
  • InjuryAug 7, 2024Failure to Osseointegrate; Failure to Osseointegrate

    CUSTOMER STATES "OTHER PRODUCT DEFICIENCIES AND TECHNICAL", CUSTOMER CLAIM INDICATES, FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 19929650 ↗
  • InjuryJun 13, 2024Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant

    MAUDE report 19531874 ↗
  • InjuryFeb 2, 2024Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant

    MAUDE report 18635119 ↗
  • InjuryJan 3, 2024Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO INTEGRATE.

    Patient problems: Failure of Implant; Inflammation

    MAUDE report 18438831 ↗
  • InjuryAug 9, 2023Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Inflammation

    MAUDE report 17491736 ↗
  • InjuryAug 4, 2023Positioning Failure; Positioning Failure

    PER COMPLAINT (B)(4), DURING CLINICAL PROCEDURE, PATIENT EXPERIENCED LACK OF PRIMARY STABILITY.

    Patient problems: Failure of Implant

    MAUDE report 17459220 ↗
  • InjuryJul 18, 2023Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Granuloma; Wound Dehiscence

    MAUDE report 17344537 ↗
  • InjuryJun 28, 2023Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(6) AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE

    Patient problems: Failure of Implant; Osteopenia/ Osteoporosis

    MAUDE report 17222460 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K130572. One submission often covers many models, so check the product and lot details in each record.

  • Z-0363-2020 · Oct 26, 2018 · Terminated
    Implant Direct, REF654311U, simply InterActive Implant, Surface: SBM, Qty 1, 4.3mmD x 11.5mmL, 3.4mmD Platform, RX only, Sterile R Dental Implant
  • Z-1917-2018 · Mar 14, 2018 · Terminated
    ImplantDirect simply InterActive Implant, 5.0mmD X 10mmL, SBM: 3.4mmD Platform, Part #655010U, Rx, Sterile. Incorrect label on the cap says 4.3mmD Platform 604313U 13mmL. Produ
  • Z-0539-2018 · Jan 23, 2018 · Terminated
    Implant Direct, INTERACTIVE HEALING COLLAR, PART NUMBER 6530-15, 5.0mmL: 3.0mmD Platform
  • Z-2551-2018 · Mar 3, 2017 · Terminated
    ImplantDirect, Dental implants intended for use in partially and fully edentulous upper and lower jaws in support of single or multiple-unit restorations and terminal or intermedia

Other Implant, Endosseous, Root-Form devices

All Implant, Endosseous, Root-Form devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page