Skip to content

simply InterActive® Implant 655013URecalls & reported problems

Implant Direct Sybron Manufacturing LLC · Ø3.7 x 8 Platform 3.5mmD · Class 2 · Implant

All models of simply InterActive Implant (23)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Quick summary

This Implant Direct simply InterActive dental implant is a tooth-root replacement placed in the jawbone. All 88 reports are injuries, mostly describing the implant failing to bond with the bone, and some mention infection or inflammation around it. No deaths are listed. Reports rose from 4 in the prior 12 months to 18 in the last 12 months. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
88
Deaths reported
0
Injuries reported
88
Recalls naming it
0

Summary

The FDA's MAUDE database contains 88 adverse event reports that list this exact device (DI 10841307107019), received between Oct 5, 2018 and Aug 6, 2026 — classified as 88 injuries.

The most frequently reported specific device problem is “Failure to Osseointegrate” (52 reports).

4 other recalls cover devices cleared under the same FDA submission (K130572); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 2 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 7 reportsDec 2025: 1 reportsJan 2026: 1 reportsFeb 2026: 2 reportsMar 2026: 2 reportsApr 2026: 1 reportsMay 2026: 2 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520267
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate52
  • Loss of Osseointegration15
  • Osseointegration Problem7
  • Positioning Failure7
  • Malposition of Device4
  • Positioning Problem3
  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Failure of Implant65
  • No Clinical Signs, Symptoms or Conditions18
  • Inadequate Osseointegration17
  • Unspecified Infection16
  • Granuloma15
  • Inflammation14
  • Fibrosis10
  • Osteopenia/ Osteoporosis7

Recent adverse event reports

The 25 most recent of 88 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 6, 2026Failure to Osseointegrate

    Failure to osseointegrate.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 50166090 ↗
  • InjuryJul 3, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Abscess; Inadequate Osseointegration

    MAUDE report 25707312 ↗
  • InjuryMay 13, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 25164451 ↗
  • InjuryMay 11, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Abscess; Inadequate Osseointegration

    MAUDE report 25139876 ↗
  • InjuryApr 13, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24864274 ↗
  • InjuryMar 30, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24735725 ↗
  • InjuryMar 9, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24547239 ↗
  • InjuryFeb 4, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24261674 ↗
  • InjuryFeb 3, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24251794 ↗
  • InjuryJan 22, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; Unspecified Infection

    MAUDE report 24146904 ↗
  • InjuryDec 1, 2025Malposition of Device; Malposition of Device

    LACK OF PRIMARY STABILITY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23680370 ↗
  • InjuryNov 28, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23675560 ↗
  • InjuryNov 19, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23594011 ↗
  • InjuryNov 12, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; Unspecified Infection

    MAUDE report 23532807 ↗
  • InjuryNov 6, 2025Malposition of Device; Malposition of Device

    INCORRECT PART USED DUE TO INSUFFIC INFO.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23483718 ↗
  • InjuryNov 6, 2025Malposition of Device; Malposition of Device

    LACK OF PRIMARY STABILITY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23483696 ↗
  • InjuryNov 5, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Implant Pain; Inadequate Osseointegration

    MAUDE report 23474388 ↗
  • InjuryNov 4, 2025Malposition of Device; Malposition of Device

    LACK OF PRIMARY STABILITY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23461299 ↗
  • InjuryOct 30, 2025Positioning Failure; Osseointegration Problem; Positioning Failure; Osseointegration Problem

    LACK OF PRIMARY STABILITY.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23430078 ↗
  • InjuryMar 31, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 21734602 ↗
  • InjuryMar 11, 2025Positioning Failure; Positioning Failure

    LACK OF PRIMARY STABILITY

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21579667 ↗
  • InjuryJan 7, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 21096986 ↗
  • InjuryOct 17, 2024Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 20474961 ↗
  • InjuryAug 28, 2024Positioning Failure; Positioning Failure

    COMPL:PRIMARY STABILITY COULDN¿T BE ACHI.

    Patient problems: Failure of Implant

    MAUDE report 20089475 ↗
  • InjuryApr 26, 2024Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 19196227 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K130572. One submission often covers many models, so check the product and lot details in each record.

  • Z-0363-2020 · Oct 26, 2018 · Terminated
    Implant Direct, REF654311U, simply InterActive Implant, Surface: SBM, Qty 1, 4.3mmD x 11.5mmL, 3.4mmD Platform, RX only, Sterile R Dental Implant
  • Z-1917-2018 · Mar 14, 2018 · Terminated
    ImplantDirect simply InterActive Implant, 5.0mmD X 10mmL, SBM: 3.4mmD Platform, Part #655010U, Rx, Sterile. Incorrect label on the cap says 4.3mmD Platform 604313U 13mmL. Produ
  • Z-0539-2018 · Jan 23, 2018 · Terminated
    Implant Direct, INTERACTIVE HEALING COLLAR, PART NUMBER 6530-15, 5.0mmL: 3.0mmD Platform
  • Z-2551-2018 · Mar 3, 2017 · Terminated
    ImplantDirect, Dental implants intended for use in partially and fully edentulous upper and lower jaws in support of single or multiple-unit restorations and terminal or intermedia

Other Implant, Endosseous, Root-Form devices

All Implant, Endosseous, Root-Form devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page