Skip to content

simply Legacy™3 Implant 854211URecalls & reported problems

Implant Direct Sybron Manufacturing LLC · Ø3.7 x 8 Platform 3.5mmD · Class 2 · Implant

All models of simply Legacy3 Implant (39)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Simply Legacy 3 dental implant is a small root-form screw used to anchor a replacement tooth in the jawbone. Most of the 74 reports describe the implant failing to fuse with the surrounding bone, or becoming loose after it had already fused, sometimes with positioning problems, local inflammation or infection, and one case where the implant fractured. The reports describe 73 injuries and no deaths. No recalls name this device. Reports have picked up in the past year, rising from 2 in the prior12 months to 8.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
74
Deaths reported
0
Injuries reported
73
Recalls naming it
0

Summary

The FDA's MAUDE database contains 74 adverse event reports that list this exact device (DI 10841307107811), received between Apr 23, 2018 and Aug 11, 2026 — classified as 73 injuries, 1 malfunction.

The most frequently reported specific device problem is “Failure to Osseointegrate” (43 reports).

2 other recalls cover devices cleared under the same FDA submission (K192221); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 2 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 3 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 1 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate43
  • Positioning Failure11
  • Osseointegration Problem8
  • Loss of Osseointegration4
  • Positioning Problem3
  • Biocompatibility1
  • Component Incompatible1
  • Fracture1

Patient problems

  • Failure of Implant61
  • Inflammation12
  • Inadequate Osseointegration11
  • No Clinical Signs, Symptoms or Conditions10
  • Unspecified Infection10
  • Osteopenia/ Osteoporosis7
  • No Consequences Or Impact To Patient6
  • Fibrosis4

Recent adverse event reports

The 25 most recent of 74 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 11, 2026Failure to Osseointegrate

    Failure to osseointegrate.

    Patient problems: Inadequate Osseointegration; Unspecified Infection

    MAUDE report 50203178 ↗
  • InjuryMay 13, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 25162178 ↗
  • InjuryApr 14, 2026Positioning Failure; Osseointegration Problem

    LACK OF PRIMARY STABILITY.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24877995 ↗
  • InjuryMar 11, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; Inflammation

    MAUDE report 24570612 ↗
  • InjuryJan 7, 2026Positioning Failure

    LACK OF PRIMARY STABILITY

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23996671 ↗
  • InjuryNov 14, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23551578 ↗
  • InjuryNov 14, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23551576 ↗
  • InjuryNov 4, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration

    MAUDE report 23461231 ↗
  • InjuryOct 24, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23379245 ↗
  • InjuryMar 7, 2025Component Incompatible; Component Incompatible

    LACK OF PRIMARY STABILITY

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21552818 ↗
  • InjuryJun 18, 2024Premature Separation; Premature Separation

    PART NOT RETAINED ON MATING PART.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19561573 ↗
  • InjuryMay 11, 2024Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 19295316 ↗
  • InjuryMay 9, 2024Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 19281205 ↗
  • InjuryJan 31, 2024Failure to Osseointegrate; Failure to Osseointegrate

    LACK OF PRIMARY STABILITY.

    Patient problems: Failure of Implant

    MAUDE report 18617342 ↗
  • InjuryOct 19, 2023Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Inflammation; Unspecified Infection

    MAUDE report 17964523 ↗
  • InjuryOct 19, 2023Positioning Failure; Positioning Failure

    PER COMPLAINT (B)(4), DURING CLINICAL PROCEDURE, PATIENT EXPERIENCED LACK OF PRIMARY STABILITY.

    Patient problems: Failure of Implant

    MAUDE report 17964521 ↗
  • InjuryOct 17, 2023Positioning Failure; Positioning Failure

    PER COMPLAINT (B)(4), DURING CLINICAL PROCEDURE, PATIENT EXPERIENCED LACK OF PRIMARY STABILITY.

    Patient problems: Failure of Implant

    MAUDE report 17947772 ↗
  • InjuryJul 26, 2023Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Pain

    MAUDE report 17396766 ↗
  • InjuryJun 23, 2023Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant

    MAUDE report 17188443 ↗
  • InjuryFeb 16, 2023Osseointegration Problem; Osseointegration Problem

    PER COMPLAINT (B)(4), DURING CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant

    MAUDE report 16385244 ↗
  • InjuryFeb 6, 2023Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4)., AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Fibrosis; Granuloma

    MAUDE report 16304072 ↗
  • InjuryFeb 3, 2023Loss of Osseointegration; Loss of Osseointegration

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED LOSS OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Granuloma; Inflammation

    MAUDE report 16288957 ↗
  • InjuryOct 25, 2022Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), DURING CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant

    MAUDE report 15667160 ↗
  • InjurySep 30, 2022Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), AFTER CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant

    MAUDE report 15515139 ↗
  • InjurySep 29, 2022Failure to Osseointegrate; Failure to Osseointegrate

    PER COMPLAINT (B)(4), DURING CLINICAL PROCEDURE, PATIENT EXPERIENCED FAILURE OF IMPLANT TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Insufficient Information

    MAUDE report 15506995 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K192221. One submission often covers many models, so check the product and lot details in each record.

  • Z-0198-2022 · Sep 23, 2021 · Open, Classified
    ImplantDirect, REF 834713, Legacy 2 Implant 4.7mmD x 13mmL, 4.5mmD Platform,
  • Z-0197-2022 · Sep 23, 2021 · Open, Classified
    ImplantDirect, REF 834711, Legacy 2 Implant 4.7mmD x 11.5mmL, 4.5mmD Platform,

Other Implant, Endosseous, Root-Form devices

All Implant, Endosseous, Root-Form devices →

Sources and updates