Quick summary

This Implant Direct simply Legacy 3 dental implant has 134 reports. Most describe the implant failing to bond with the jawbone or lacking stability when placed. The reports mention 131 injuries and no deaths, and no recalls name this device. Reports rose to 19 in the last 12 months from 8 in the previous 12.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
134
Deaths reported
0
Injuries reported
131
Recalls naming it
0

Summary

The FDA's MAUDE database contains 134 adverse event reports that list this exact device (DI 10841307107859), received between Apr 3, 2019 and Aug 11, 2026 — classified as 131 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Failure to Osseointegrate” (78 reports).

2 other recalls cover devices cleared under the same FDA submission (K192221); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 1 reportsOct 2024: 3 reportsNov 2024: 2 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 3 reportsNov 2025: 9 reportsDec 2025: 0 reportsJan 2026: 3 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 3 reportsMay 2026: 1 reportsJun 2026: 2 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520269
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate78
  • Positioning Failure21
  • Loss of Osseointegration14
  • Malposition of Device6
  • Positioning Problem6
  • Adverse Event Without Identified Device or Use Problem4
  • Osseointegration Problem3
  • Difficult to Insert2

Patient problems

  • Failure of Implant104
  • No Clinical Signs, Symptoms or Conditions24
  • Osteopenia/ Osteoporosis24
  • Inflammation20
  • Inadequate Osseointegration19
  • Unspecified Infection17
  • No Consequences Or Impact To Patient12
  • Pain10

Recent adverse event reports

The 25 most recent of 134 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 11, 2026Failure to Osseointegrate

    Failure to osseointegrate.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 50202786 ↗
  • InjuryJun 4, 2026Positioning Failure

    LACK OF STABILITY DURING PLACEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25403085 ↗
  • InjuryJun 4, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; Unspecified Infection

    MAUDE report 25403061 ↗
  • InjuryMay 26, 2026Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Fibrosis; Inadequate Osseointegration

    MAUDE report 25285781 ↗
  • InjuryApr 30, 2026Positioning Failure

    PART NOT RETURNED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25045846 ↗
  • InjuryApr 28, 2026Positioning Failure

    LACK OF STABILITY DURING PLACEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25017718 ↗
  • InjuryApr 3, 2026Failure to Osseointegrate; Migration

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24775382 ↗
  • InjuryJan 6, 2026Malposition of Device

    LACK OF PRIMARY STABILITY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23982585 ↗
  • InjuryJan 1, 2026Malposition of Device

    LACK OF STABILITY DURING PLACEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23939757 ↗
  • InjuryJan 1, 2026Difficult to Insert; Malposition of Device

    LACK OF STABILITY DURING PLACEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23939755 ↗
  • InjuryNov 10, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23515253 ↗
  • InjuryNov 6, 2025Malposition of Device; Malposition of Device

    LACK OF STABILITY DURING PLACEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23483717 ↗
  • InjuryNov 5, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Abscess; Inadequate Osseointegration

    MAUDE report 23482817 ↗
  • InjuryNov 4, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23463042 ↗
  • InjuryNov 4, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23463035 ↗
  • InjuryNov 4, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; Inflammation

    MAUDE report 23462802 ↗
  • InjuryNov 4, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Inadequate Osseointegration; Unspecified Infection

    MAUDE report 23462785 ↗
  • InjuryNov 4, 2025Positioning Failure; Positioning Failure

    LACK OF STABILITY DURING PLACEMENT.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23462781 ↗
  • InjuryNov 4, 2025Positioning Failure; Adverse Event Without Identified Device or Use Problem; Positioning Failure; Adverse Event Without Identified Device or Use Problem

    TRAUMA / CLINICAL COMPLICATION ONLY.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23461567 ↗
  • InjuryOct 31, 2025Positioning Failure; Positioning Failure

    LACK OF PRIMARY STABILITY.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23436874 ↗
  • InjuryOct 31, 2025Loss of Osseointegration; Loss of Osseointegration

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23436787 ↗
  • InjuryOct 31, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23436602 ↗
  • InjuryApr 2, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 21756727 ↗
  • InjuryMar 20, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 21658586 ↗
  • InjuryDec 4, 2024Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration; No Clinical Signs, Symptoms or Conditions

    MAUDE report 20849320 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K192221. One submission often covers many models, so check the product and lot details in each record.

  • Z-0197-2022 · Sep 23, 2021 · Open, Classified
    ImplantDirect, REF 834711, Legacy 2 Implant 4.7mmD x 11.5mmL, 4.5mmD Platform,
  • Z-0198-2022 · Sep 23, 2021 · Open, Classified
    ImplantDirect, REF 834713, Legacy 2 Implant 4.7mmD x 13mmL, 4.5mmD Platform,

Other Implant, Endosseous, Root-Form devices

All Implant, Endosseous, Root-Form devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page