WEBSTER D708DR002RTRecalls & reported problems
Biosense Webster Inc · Class 2
All models of WEBSTER (29)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10846835000269), received between Mar 27, 2018 and Jan 12, 2022 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Device Issue” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Device Issue2
- Material Frayed2
- Material Separation1
Patient problems
- No Consequences Or Impact To Patient2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 12, 2022Material Separation; Material Separation
IT WAS REPORTED THAT A PATIENT UNDERWENT A SUPRAVENTRICULAR TACHYCARDIA (SVT) ABLATION PROCEDURE WITH A WEBSTER¿ ELECTROPHYSIOLOGY CATHETER AND THE CATHETER KINKED RESULTING IN A BREAKAGE WHICH EXPOSED INTERNAL WIRING. IT WAS REPORTED THAT UPON ADVANCING THE WEBSTER¿ ELECTROPHYSIOLOGY CATHETER, IT DID NOT ADVANCE CORRECTLY INTO THE ZONE ON THE CARTO 3 SYSTEM. WHEN THE CATHETER WAS REMOVED FROM THE BODY THEY NOTICED THE CATHETER LOOP HAD KINKED AND THE INSULATION WAS BROKEN. THE DAMAGE WAS NOT NOTICED BEFORE THE CATHETER BEING INSERTED INTO THE BODY. THE CATHETER WAS REPLACED USING THE SAME SHEATH TO RESOLVE THE ISSUE. ADDITIONAL INFORMATION WAS RECEIVED INDICATING THE INSULATION WAS BROKEN, AND THERE APPEARED TO BE EXPOSED WIRES. THE DAMAGE DID NOT RESULT IN ANY LIFTED OR SHARP RINGS. THE CATHETER PROLAPSED WITHIN THE VESSEL AND EVENTUALLY DOUBLED BACK SUPERIORLY. THE CATHETER WAS NOT PRE-SHAPED, THE PHYSICIAN ATTEMPTED TO ADVANCE THE CATHETER THE SAME AS SHE ALWAYS DOES BUT THERE WAS DIFFICULTY DURING INSERTION. THE SHEATH USED WAS A FASTCATH 7F SHORT SHEATH (NON-BWI).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13237884 ↗MalfunctionMar 27, 2018Material Frayed; Device Issue; Material Frayed; Device Issue
IT WAS REPORTED THAT A PATIENT UNDERWENT AN ATRIAL FLUTTER LEFT (L-AFL) PROCEDURE WITH A WEBSTER¿ ELECTROPHYSIOLOGY CATHETER. IT WAS REPORTED THAT THE CATHETER WAS NOT DEFLECTING PROPERLY DUE TO A DEFECTIVE PULLER WIRE. IT WAS ALSO REPORTED THAT SOME OF THE INSULATION OF THE CATHETER WAS EXPOSED. THE CATHETER WAS REPLACED AND THE DEFLECTION ISSUE REMAINED. THE CATHETER WAS REPLACED AGAIN AND THE ISSUE RESOLVED. NO PATIENT CONSEQUENCE WAS REPORTED. THE RESPONSE RECEIVED CONFIRMED THAT THE PHYSICIAN REPORTED THAT HE RUBBED WITH HIS GLOVED FINGER AN ELECTRODE RING ON BOTH CATHETERS AND FELT SHARP EDGES. THE ISSUE WAS OBSERVED PRIOR TO INSERTION INTO THE BODY UPON REMOVAL FROM STERILE PACKAGE. IT WAS ALSO CONFIRMED THAT THE INSULATION EXPOSED WAS OBSERVED PROXIMAL TO THE DISTAL PAIR OF ELECTRODES. THE CATHETER WAS NOT PRE-SHAPED. THE DEFLECTION ISSUE WAS ASSESSED AS NOT REPORTABLE. SINCE THE CATHETER IS UNABLE TO DEFLECT OR RELAX COMPLETELY, THE USER WILL NOT BE ABLE TO USE THE DEVICE AND WILL HAVE TO REPLACE IT. THE POTENTIAL RISK THAT IT COULD CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS DETERIORATION IN STATE OF HEALTH WAS REMOTE. THE SHARP RING EDGES AND INSULATION EXPOSED ISSUES WERE
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7374656 ↗MalfunctionMar 27, 2018Material Frayed; Device Issue; Material Frayed; Device Issue
IT WAS REPORTED THAT A PATIENT UNDERWENT AN ATRIAL FLUTTER LEFT (L-AFL) PROCEDURE WITH A WEBSTER¿ ELECTROPHYSIOLOGY CATHETER. IT WAS REPORTED THAT THE CATHETER WAS NOT DEFLECTING PROPERLY DUE TO A DEFECTIVE PULLER WIRE. IT WAS ALSO REPORTED THAT SOME OF THE INSULATION OF THE CATHETER WAS EXPOSED. THE CATHETER WAS REPLACED AND THE DEFLECTION ISSUE REMAINED. THE CATHETER WAS REPLACED AGAIN AND THE ISSUE RESOLVED. NO PATIENT CONSEQUENCE WAS REPORTED. THE RESPONSE RECEIVED CONFIRMED THAT THE PHYSICIAN REPORTED THAT HE RUBBED WITH HIS GLOVED FINGER AN ELECTRODE RING ON BOTH CATHETERS AND FELT SHARP EDGES. THE ISSUE WAS OBSERVED PRIOR TO INSERTION INTO THE BODY UPON REMOVAL FROM STERILE PACKAGE. IT WAS ALSO CONFIRMED THAT THE INSULATION EXPOSED WAS OBSERVED PROXIMAL TO THE DISTAL PAIR OF ELECTRODES. THE CATHETER WAS NOT PRE-SHAPED. THE DEFLECTION ISSUE WAS ASSESSED AS NOT REPORTABLE. SINCE THE CATHETER IS UNABLE TO DEFLECT OR RELAX COMPLETELY, THE USER WILL NOT BE ABLE TO USE THE DEVICE AND WILL HAVE TO REPLACE IT. THE POTENTIAL RISK THAT IT COULD CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS DETERIORATION IN STATE OF HEALTH WAS REMOTE. THE SHARP RING EDGES AND INSULATION EXPOSED ISSUES WERE
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7374588 ↗
FDA clearance and classification
The device record lists FDA submission K892265; its details are not in the openFDA clearance files we use.
The FDA regulates product code DRF (catheter, electrode recording, or probe, electrode recording) under 21 CFR 870.1220 as a Class II device. 21 CFR 870.1220 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the WEBSTER D708DR002RT
Has the WEBSTER D708DR002RT been recalled?
No FDA recall record in our data names this exact device identifier (DI 10846835000269), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the WEBSTER D708DR002RT?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Mar 27, 2018 and Jan 12, 2022. In those reports, the most common specific device problems are “Device Issue” (2), “Material Frayed” (2) and “Material Separation” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the WEBSTER D708DR002RT?
None of the reports are classified as deaths, 0 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the WEBSTER D708DR002RT, and is it still sold?
The FDA's device database lists Biosense Webster Inc as the company responsible for it (brand WEBSTER, model D708DR002RT). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices
- IntellaMap Orion™ M004RC64S0Boston Scientific Corporation · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths356 reports
- Advisor™ HD Grid, Sensor Enabled™ D-AVHD-DF16St. Jude Medical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths356 reports
- ACHIEVE™ 990063-020Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING7 deaths129 reports
- Inquiry™ IBI-81104Irvine Biomedical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 recall2 deaths64 reports
- DECANAV R7F282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING4 deaths108 reports
- LASSO NAV D134301Biosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING2 deaths82 reports
- DECANAV R7D282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 death76 reports
- ACHIEVE ADVANCE™ 2ACH20Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING3 deaths69 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page