Celsius D7TCFL252RTRecalls & reported problems
Biosense Webster Inc · Class 3
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10846835000405), received between Nov 24, 2021 and Mar 22, 2024 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Material Protrusion/Extrusion” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Material Protrusion/Extrusion2
- Break1
- Material Twisted/Bent1
- Positioning Failure1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 22, 2024Material Protrusion/Extrusion; Material Twisted/Bent; Material Protrusion/Extrusion; Material Twisted/Bent
IT WAS REPORTED THAT A PATIENT UNDERWENT A CARDIAC ABLATION PROCEDURE WITH A CELSIUS¿ ELECTROPHYSIOLOGY CATHETER AND WHEN OPENING THE PACKAGE, UPON VISUAL INSPECTION, THE CATHETER APPEARED DEFECTIVE ON THE CATHETER TIP, JUST BELOW PROXIMAL ELECTRODES. THERE WAS A BEND AT THE DISTAL PORTION AND BRAIDING EXPOSED. THE CATHETER WAS NOT INSERTED IN PATIENT. THE CATHETER WAS REPLACED. THERE WAS NO PATIENT CONSEQUENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18957051 ↗MalfunctionSep 18, 2023Positioning Failure; Material Protrusion/Extrusion; Positioning Failure; Material Protrusion/Extrusion
IT WAS REPORTED THAT A PATIENT UNDERWENT A CARDIAC ABLATION PROCEDURE WITH A CELSIUS¿ ELECTROPHYSIOLOGY CATHETER. AFTER CONNECTING THE CATHETER TO A ST. JUDE MEDICAL RADIOFREQUENCY (RF) GENERATOR AND RECORDING SYSTEM, THE PHYSICIAN INSERTED THE CATHETER INTO THE PATIENT. SOMETHING ABNORMAL WAS SEEN ON THE XRAY SO THE PHYSICIAN REMOVED THE CATHETER FROM THE PATIENT. THE PHYSICIAN DEFLECTED THE CATHETER, AND THE CURVE APPEARED ABNORMAL. WHEN CHECKING THE CATHETER CLOSELY, IT APPEARED TO BE DEFECTIVE. THE CATHETER IS NOT COATED AND WIRES CAN BE SEEN. THERE WERE NO LIFTED NOR SHARP RINGS AND THERE WAS NO RESISTANCE DURING INSERTION AND REMOVAL OF THE CATHETER. THE ISSUE WITH THE CURVE OF THE CATHETER WAS ASSESSED AS NOT MDR REPORTABLE. THE POTENTIAL THAT IT COULD CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS INJURY, OR OTHER SIGNIFICANT ADVERSE EVENT, IS REMOTE. THE WIRES EXPOSED ISSUE IS MDR REPORTABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17765937 ↗MalfunctionNov 24, 2021Break; Break
IT WAS REPORTED THAT AN UNKNOWN PATIENT HAD A FAILED CELSIUS¿ ELECTROPHYSIOLOGY CATHETER IN ITS ISOLATION NEAR THE PROXIMAL ELECTRODES WHERE A CUT WAS SEEN IN ITS SILICONE COATING. IT WAS REPLACED BY ANOTHER CELSIUS CATHETER. THE PROCEDURE WAS UNEVENTFUL WITH NO DELAY AND THERE WAS NO HARM TO THE PATIENT. THE DEVICE WAS IN HOSPITAL¿S POSSESSION AND NOT EXPECTED TO BE RETURNED. BROKEN TIP IS MDR-REPORTABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12872888 ↗
Other Cardiac ablation percutaneous catheter devices
- THERMOCOOL SMARTTOUCH SF D134805Biosense Webster Inc · Cardiac ablation percutaneous catheter1 recall176 deaths4,106 reports
- THERMOCOOL SMARTTOUCH SF D134804Biosense Webster Inc · Cardiac ablation percutaneous catheter44 deaths784 reports
- THERMOCOOL SMARTTOUCH SF D134801Biosense Webster Inc · Cardiac ablation percutaneous catheter15 deaths608 reports
- ThermoCool SmartTouch D132705Biosense Webster Inc · Cardiac ablation percutaneous catheter25 deaths574 reports
- THERMOCOOL SMARTTOUCH SF D134702Biosense Webster Inc · Cardiac ablation percutaneous catheter19 deaths366 reports
- THERMOCOOL SMARTTOUCH SF D134701Biosense Webster Inc · Cardiac ablation percutaneous catheter11 deaths278 reports
- ThermoCool SmartTouch D133602Biosense Webster Inc · Cardiac ablation percutaneous catheter8 deaths225 reports
- SMARTABLATE SAT001Biosense Webster Inc · Cardiac ablation percutaneous catheter185 reports