WEBSTER F6QA005RTRecalls & reported problems

Biosense Webster Inc · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10846835000481), received between Dec 12, 2025 and Dec 12, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Patient Device Interaction Problem1

Patient problems

  • Cardiac Arrest1
  • Ventricular Fibrillation1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 12, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    DURING CARDIAC ABLATION PROCEDURE WITH A WEBSTER QUAD CATHETER, THE PATIENT EXPERIENCED VENTRICULAR FIBRILLATION (VF) TREATED WITH CHEST COMPRESSIONS AND DEFIBRILLATION ABOUT 5-6 TIMES. THE LAST KNOWN STATUS OF THE PATIENT WAS THAT THEIR BLOOD PRESSURE WAS NORMAL, THEY WERE IN SINUS RHYTHM, AND A STAT ECHO WAS ORDERED. IT WAS REPORTED THAT WHILE STEMMING THE VENTRICLE TO SEE THE SEVERITY OF THE PATIENT'S VT (VENTRICULAR TACHYCARDIA), IT STARTED IN VT AND DETERIORATED INTO VF. THE PATIENT¿S BLOOD PRESSURE PLUMMETED, AND THE MEDICAL TEAM HAD TO CALL A CODE. THE PATIENT WAS ALREADY INTUBATED WHEN THEY NOTICED THE DROP IN BLOOD PRESSURE. THEY NOTICED THIS DUE TO THE 12LEAD BEING ALL VF AND WAS CONFIRMED ON X-RAY AND WITH THE QUAD CATHETER THAT WAS IN THE RIGHT VENTRICLE. THE ONLY KNOWN MEDICAL INTERVENTION PROVIDED TO THE PATIENT WERE CHEST COMPRESSIONS AND DEFIBRILLATION ABOUT 5-6 TIMES. THE ONLY BWI IN USE AT THE TIME WAS A QUAD CATHETER (FIX 6F,4P,A,SD,5MM,10PN-DR,115), CARTO 3 SYSTEM, AND PATCHES ON THE PATIENT. NO GENERATOR WAS IN USE, AND THE CASE WAS ABORTED. THE INFORMATION RECEIVED INDICATED THAT THE INTERVENTION PROVIDED WAS ANESTHESIA PROTOCOL. THE OUTCOME OF THE ADVERSE EVE

    Patient problems: Cardiac Arrest; Ventricular Fibrillation

    MAUDE report 23796296 ↗

Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices

All CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices →