WEBSTER 1086259RTRecalls & reported problems
Biosense Webster Inc · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10846835001181), received between Jan 17, 2020 and Jan 17, 2020 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Cardiac Tamponade1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 17, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A FEMALE PATIENT UNDERWENT AN IDIOPATHIC VENTRICULAR TACHYCARDIA (IDVT) ABLATION PROCEDURE WITH A WEBSTER¿ ELECTROPHYSIOLOGY CATHETER AND SUFFERED CARDIAC TAMPONADE REQUIRING PERICARDIOCENTESIS. DURING THE PROCEDURE WHILE USING AN STSF CATHETER NOISE WAS OBSERVED FROM THE CATHETER ELECTRODES BEING DISPLAYED ON THE CARTO 3 AND ELECTROPHYSIOLOGY RECORDING SYSTEMS. THE CABLE WAS REPLACED, BUT THE ISSUE REMAINED. THE CATHETER WAS THEN EXCHANGED, AND THE ISSUE WAS RESOLVED. THE PROCEDURE CONTINUED SUCCESSFULLY. THE CARTO 3 SYSTEM WAS OPERATING PER SPECIFICATIONS AND IS NOT CONSIDERED RESPONSIBLE OF THE ISSUE. THE CATHETER WAS DETERMINED TO BE THE ROOT CAUSE OF THE ISSUE EXPERIENCED. IT WAS ALSO REPORTED THAT PERICARDIAL EFFUSION WAS NOTED AFTER TRANSSEPTAL ACCESS AND AFTER SOME ABLATIONS WERE DONE WITH THE REPLACEMENT STSF CATHETER. THE PATIENT¿S SYSTOLIC BLOOD PRESSURE DROPPED TO 90, AND CARDIAC TAMPONADE WAS CONFIRMED BY ULTRASOUND AND INTRACARDIAC ECHOCARDIOGRAPHY (ICE). PERICARDIOCENTESIS WAS PERFORMED AND A TOTAL OF 330 CC OF FLUID WAS REMOVED FROM THE PERICARDIAL SPACE. THE PROCEDURE CONTINUED AND SOME OTHER ABLATIONS WERE DONE. HOWEVER, THE PROCEDURE WAS UNAB
Patient problems: Cardiac Tamponade
MAUDE report 9603669 ↗
Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices
- Advisor™ HD Grid, Sensor Enabled™ D-AVHD-DF16St. Jude Medical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths358 reports
- IntellaMap Orion™ M004RC64S0Boston Scientific Corporation · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths356 reports
- ACHIEVE™ 990063-020Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING7 deaths129 reports
- Inquiry™ IBI-81104Irvine Biomedical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 recall2 deaths64 reports
- DECANAV R7F282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING4 deaths108 reports
- LASSO NAV D134301Biosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING2 deaths82 reports
- DECANAV R7D282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 death75 reports
- ACHIEVE ADVANCE™ 2ACH20Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING3 deaths69 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.