CRISTA CATH D7A20131RTRecalls & reported problems
Biosense Webster Inc · Class 2
- Adverse event reports
- 2
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10846835005042), received between Oct 24, 2022 and Aug 21, 2024 — classified as 1 death, 1 malfunction.
The most frequently reported specific device problem is “Tear, Rip or Hole in Device Packaging” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Tear, Rip or Hole in Device Packaging1
Patient problems
- Cardiac Arrest1
- Hemorrhage/Blood Loss/Bleeding1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
DeathAug 21, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT AN ISCHEMIC VENTRICULAR TACHYCARDIA (ISVT) ABLATION PROCEDURE WITH A WEBSTER CS AND A CRISTA CATH AND THE PATIENT EXPERIENCED CARDIAC ARREST AND HEMORRHAGE THAT RESULTED IN DEATH. THE PATIENTS PRESSURE DROPPED SIGNIFICANTLY DURING TRANSESOPHAGEAL ECHOCARDIOGRAM (TEE) PRIOR TO TRANSEPTAL PUNCTURE. AFTER THIS WAS NOTICED, CARDIOPULMONARY RESUSCITATION (CPR) WAS ADMINISTERED. THE PATIENTS' PRESSURE WOULD RECOVER SLIGHTLY AND THEN FALL AGAIN - ALL WHILE GOING IN AND OUT OF VENTRICULAR TACHYCARDIA (VT). PATIENT WAS SHOCKED BACK INTO NORMAL RHYTHM WHEN NEEDED. INTERVENTIONAL RADIOLOGY (IR) WAS CALLED TO CHECK FOR AORTIC AND RETROPERITONEAL BLEED WITH NO FINDINGS. CARDIO VASCULAR (CV) SURGERY WAS CALLED AND PLACED THE PATIENT ON ECMO. THE PATIENT WAS STABLE AND ON ECMO AND THEN SHORTLY AFTER THE PATIENT STARTED TO CODE. CV SURGERY, IR AND EPS WERE ALL IN THE ROOM ATTEMPTING TO FIGURE OUT THE PROBLEM. IT WAS NOTICED THE PATIENT¿S ABDOMEN WAS DISTENDED. PHYSICIANS SURGICALLY OPENED THE BELLY AND FOUND THE ABDOMEN WAS FULL OF BLOOD. AFTER A LONG-STANDING EFFORT, ANESTHESIA SAID THE PUPILS WERE NON-REACTIVE AND BLOWN. THE CAUSE OF THE BLEED REMAINS UNK
Patient problems: Cardiac Arrest; Hemorrhage/Blood Loss/Bleeding
MAUDE report 20019351 ↗MalfunctionOct 24, 2022Tear, Rip or Hole in Device Packaging; Tear, Rip or Hole in Device Packaging
IT WAS REPORTED THAT AN UNKNOWN PATIENT UNDERWENT AN UNKNOWN ABLATION PROCEDURE WITH A CRISTA CATH¿ ELECTROPHYSIOLOGY CATHETER. THE STERILE PACKAGING LOOKED PARTIALLY UNSEALED WHICH COMPROMISED THE PROTECTION OF THE CATHETER. THE STERILE PACKAGING LOOKED PARTIALLY UNSEALED WHICH COMPROMISED THE PROTECTION OF THE CATHETER. THERE WERE NO PATIENT CONSEQUENCES. OPEN POUCH SEAL IS MDR-REPORTABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15656949 ↗
Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices
- Advisor™ HD Grid, Sensor Enabled™ D-AVHD-DF16St. Jude Medical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths358 reports
- IntellaMap Orion™ M004RC64S0Boston Scientific Corporation · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths356 reports
- ACHIEVE™ 990063-020Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING7 deaths129 reports
- Inquiry™ IBI-81104Irvine Biomedical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 recall2 deaths64 reports
- DECANAV R7F282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING4 deaths108 reports
- LASSO NAV D134301Biosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING2 deaths82 reports
- DECANAV R7D282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 death75 reports
- ACHIEVE ADVANCE™ 2ACH20Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING3 deaths69 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.