Celsius D7BTCDL252RTRecalls & reported problems

Biosense Webster Inc · Class 2

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10846835005219), received between Oct 20, 2022 and Aug 15, 2024 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Contamination /Decontamination Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Contamination /Decontamination Problem2
  • High Readings1
  • Material Split, Cut or Torn1
  • Product Quality Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 15, 2024Contamination /Decontamination Problem; Contamination /Decontamination Problem

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN ABLATION PROCEDURE WITH A CELSIUS CATHETER AND A PIECE OF MELTED MATERIAL WAS ON THE CATHETER TIP. THE PHYSICIAN RETRACTED THE CATHETER FROM THE PATIENT¿S BODY AND NOTICED A PIECE OF MELTED MATERIAL ON THE CATHETER TIP. NO CONSEQUENCE FOR THE PATIENT. ADDITIONAL INFORMATION WAS RECEIVED ON 25-JUL-2024. THE DETAILS ON THE FOREIGN MATERIAL IS THAT IT IS PINK, 3MM SIZE, AND ELONGATED SHAPE. THE MATERIAL WAS LOOSE. THE DEVICE WAS USED ON THE PATIENT. RESPONDED YES TO CONFIRMATION IF IT WAS CHAR/CLOT ON THE TIP. ADDITIONAL CLARIFICATION WAS RECEIVED ON 08-AUG-2024 RESPONDING THAT THE REPORTER DOES NOT KNOW IF THE FOREIGN MATERIAL WAS ACTUALLY BIOLOGICAL MATERIAL AND DOES NOT KNOW IF IT IS CHAR. THE ISSUE WAS ASSESSED AS MDR REPORTABLE FOR FOREIGN MATERIAL ON THE USABLE LENGTH OF THE CATHETER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19997216 ↗
  • MalfunctionApr 12, 2023Contamination /Decontamination Problem; Contamination /Decontamination Problem

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN ABLATION PROCEDURE WITH A CELSIUS¿ ELECTROPHYSIOLOGY CATHETER AND A FOREIGN MATERIAL ON THE USABLE LENGTH OF THE CATHETER ISSUE OCCURRED. THE PHYSICIAN COMPLAINED THAT SOME STRANGE MATERIAL (PROBABLY PLASTIC) WAS PRESENT AT THE TIP OF THE CATHETER AND FOR SAFETY REASONS HE DECIDED TO UNPACK A NEW CATHETER. THE SURGERY WAS DELAYED 3 MINUTES DUE TO THE REPORTED ISSUE. THE ACTION TAKEN WHEN THE EVENT OCCURRED WAS TO CHANGE THE CATHETER. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO PATIENT CONSEQUENCE REPORTED. ADDITIONAL INFORMATION WAS RECEIVED. THE REPORTER WAS UNABLE TO SEE THE MATERIAL BECAUSE NO CLINICAL SUPPORT WAS PRESENT WHEN THIS OCCURRED. ALL PACKAGING MATERIALS WERE DISCHARGED WHEREAS THE CATHETER WAS SENT BACK. THE CATHETER WAS NOT USED ON THE PATIENT. THE EVENT WAS ASSESSED AS MDR REPORTABLE FOR FOREIGN MATERIAL ON THE USABLE LENGTH OF THE CATHETER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16728594 ↗
  • MalfunctionOct 20, 2022Product Quality Problem; High Readings; Material Split, Cut or Torn; Product Quality Problem; High Readings; Material Split, Cut or Torn

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN ABLATION PROCEDURE WITH A CELSIUS¿ ELECTROPHYSIOLOGY CATHETER AND IT WAS OBSERVED THAT THE CATHETER DID NOT HAVE A COATING ON THE DISTAL PORTION. THE CATHETER DOES NOT HAVE A COATING ON THE DISTAL PORTION, SO IT DID NOT MARK IMPEDANCES OR IT MARKED HIGH IMPEDANCES. THE SURGERY WAS DELAYED 10 MINUTES DUE TO THE REPORTED EVENT. THE CATHETER WAS CHANGED. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WERE NO PATIENT CONSEQUENCES REPORTED. ADDITIONAL INFORMATION WAS RECEIVED. THE MATERIAL WAS CLOSED WHEN RECEIVED AT THE FACILITY. THE FAULT IS IDENTIFIED WHEN USING IT. SHEATH WAS NOT USED. THE DEVICE WAS USED ON THE PATIENT. IN PHYSICIAN¿S OPINION, THE DELAY DID NOT CONTRIBUTE TO A DEATH OR A SERIOUS INJURY TO THE PATIENT. INTERVENTION WAS NOT REQUIRED DUE TO THE DELAY. ABLATION COULD NOT BE GIVEN. TEMPERATURE WAS 50, WATTS 35, AND HIGH IMPEDANCE. ADDITIONAL FOLLOW UP HAS BEEN REQUESTED TO CLARIFY EVENT DESCRIPTION AND REGARDING RESPONSE TO FRAGMENTS QUESTION OF, ¿IF YES, WERE THEY REMOVED EASILY WITHOUT ADDITIONAL INTERVENTION? YES,¿. HOWEVER, NO FURTHER INFORMATION HAS BEEN MADE AVAILABLE. WITH THE INFORMATION AVAILABLE, THE ISSUE OF THE ¿C

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15636816 ↗

Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices

All CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices →