WEBSTER F5QA005CTRecalls & reported problems
Biosense Webster Inc · Class 2
All models of WEBSTER (29)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10846835007183), received between Aug 30, 2018 and Mar 28, 2022 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Failure to Unfold or Unwrap” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Failure to Unfold or Unwrap1
- Material Separation1
- Sharp Edges1
Patient problems
- No Consequences Or Impact To Patient2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 28, 2022Material Separation; Material Separation
IT WAS REPORTED THAT AN UNKNOWN PATIENT UNDERWENT AN UNKNOWN ABLATION PROCEDURE WITH A WEBSTER¿ ELECTROPHYSIOLOGY CATHETER WITH AUTO ID. THE CATHETER SHAFT WAS DETACHED FROM THE BODY. NO PATIENT CONSEQUENCES WERE REPORTED. MULTIPLE ATTEMPTS HAVE BEEN MADE TO OBTAIN CLARIFICATION TO THIS COMPLAINT. HOWEVER, NO FURTHER INFORMATION HAS BEEN MADE AVAILABLE. CATHETER SHAFT BROKEN WHILE INSIDE PATIENT IS MDR-REPORTABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13927290 ↗MalfunctionAug 26, 2019Failure to Unfold or Unwrap; Failure to Unfold or Unwrap
IT WAS REPORTED THAT DURING AN ABLATION PROCEDURE BEFORE THE TRANSSEPTAL WAS PERFORMED THE WEBSTER CATHETER FORMED A KNOT. THE CUSTOMER PROVIDED IMAGES CONFIRMING THE REPORT. ONCE THE KNOT FORMED IT WAS VERY HARD TO MANEUVER THE DEVICE. THE KNOTTED CATHETER WAS REMOVED BY USING A LARGER SHEATH (ST. JUDE SLO 10F). THE PROCEDURE WAS CANCELLED. THE PHYSICIAN DID NOT CONSIDER PROCEDURE CANCELLATION MAY HAVE CAUSED OR CONTRIBUTED TO A SERIOUS INJURY TO THE PATIENT. THE PATIENT REMAINED IN OBSERVATION FOR 1 ADDITIONAL DAY. NO PATIENT CONSEQUENCE WAS REPORTED. THE KNOTTED CATHETER WAS ASSESSED AS A REPORTABLE MALFUNCTION. THE PROCEDURE CANCELLATION CANCELATION WAS ASSESSED AS NOT REPORTABLE AS THERE WAS NO RISK TO THE PATIENT AS A RESULT OF THE CANCELLATION.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8932791 ↗MalfunctionAug 30, 2018Sharp Edges; Sharp Edges
IT WAS REPORTED THAT A PATIENT UNDERWENT A PROCEDURE WITH A WEBSTER CATHETER. IT WAS DESCRIBED THAT THE WEBSTER CATHETER WAS VISUALIZED UPSIDE DOWN ON THE CARTO 3 SYSTEM. THE CATHETER CABLE WAS CHANGED, BUT THE ISSUE DID NOT RESOLVE. THE WEBSTER CATHETER WAS CHANGED AND THE ISSUE RESOLVED. THE PROCEDURE WAS CONTINUED AND SUBSEQUENTLY COMPLETED. THE VISUALIZATION ISSUE WAS ASSESSED AS NOT REPORTABLE. THE USER WILL HAVE TO REPLACE THE CATHETER IN ORDER TO COMPLETE THE CASE. THE MOST LIKELY CONSEQUENCE WAS AN INTRAPROCEDURAL DELAY. THE POTENTIAL RISK THAT IT COULD CAUSE OR CONTRIBUTE TO A SERIOUS INJURY OR DEATH WAS REMOTE. THE BIOSENSE WEBSTER FAILURE ANALYSIS LAB RECEIVED THE DEVICE FOR EVALUATION. IT WAS DISCOVERED ON (B)(6) 2018 THAT ELECTRODE RING #2 WAS SHARP AT APPROXIMATELY 1.1 CM FROM THE DISTAL TIP. THE SHARP ELECTRODE WAS ASSESSED AS A REPORTABLE MALFUNCTION.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7831563 ↗
FDA clearance and classification
The FDA regulates product code DRF (catheter, electrode recording, or probe, electrode recording) under 21 CFR 870.1220 as a Class II device. 21 CFR 870.1220 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the WEBSTER F5QA005CT
Has the WEBSTER F5QA005CT been recalled?
No FDA recall record in our data names this exact device identifier (DI 10846835007183), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the WEBSTER F5QA005CT?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Aug 30, 2018 and Mar 28, 2022. In those reports, the most common specific device problems are “Failure to Unfold or Unwrap” (1), “Material Separation” (1) and “Sharp Edges” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the WEBSTER F5QA005CT?
None of the reports are classified as deaths, 0 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the WEBSTER F5QA005CT, and is it still sold?
The FDA's device database lists Biosense Webster Inc as the company responsible for it (brand WEBSTER, model F5QA005CT). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices
- IntellaMap Orion™ M004RC64S0Boston Scientific Corporation · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths356 reports
- Advisor™ HD Grid, Sensor Enabled™ D-AVHD-DF16St. Jude Medical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths356 reports
- ACHIEVE™ 990063-020Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING7 deaths129 reports
- Inquiry™ IBI-81104Irvine Biomedical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 recall2 deaths64 reports
- DECANAV R7F282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING4 deaths108 reports
- LASSO NAV D134301Biosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING2 deaths82 reports
- DECANAV R7D282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 death76 reports
- ACHIEVE ADVANCE™ 2ACH20Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING3 deaths69 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page