Skip to content

WEBSTER F5QD005RTRecalls & reported problems

Biosense Webster Inc · Class 2

All models of WEBSTER (29)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10846835007244), received between Nov 30, 2017 and Nov 30, 2017 — classified as 1 injury.

The most frequently reported specific device problem is “Entrapment of Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Entrapment of Device1

Patient problems

  • Arrhythmia1
  • No Code Available1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 30, 2017Entrapment of Device; Entrapment of Device

    IT WAS REPORTED THAT A (B)(6) FEMALE PATIENT UNDERWENT A CRYOBALLOON ABLATION PROCEDURE FOR SUPRAVENTRICULAR TACHYCARDIA (SVT) WITH WEBSTER CATHETERS X 2 AND SUFFERED A MEDICAL DEVICE ENTRAPMENT (REQUIRING SURGICAL INTERVENTION) AND HEART BLOCK. FAST ANATOMICAL MAPPING (FAM) WAS PERFORMED WITH THE NAVISTAR CATHETER. THE CORONARY SINUS CATHETER WAS POSITIONED IN THE CORONARY SINUS UNDER FAM AND CARTO-UNIVU GUIDANCE TO REDUCE RADIATION EXPOSURE. WEBSTER CATHETER # 1 WAS ADVANCED THROUGH THE INFERIOR VENA CAVA (IVC). WHILE CROSSING THE TRICUSPID ANNULUS, WEBSTER CATHETER # 1 BECAME ENTRAPPED. ATTEMPTS TO FREE THE CATHETER VIA MANUAL MANEUVERS WERE UNSUCCESSFUL. THE PROXIMAL END (CONNECTOR SIDE) OF WEBSTER CATHETER # 1 WAS CUT OFF. A 7 FRENCH GUIDING CATHETER (BRAND-UNSPECIFIED) WAS ADVANCED OVER WEBSTER CATHETER # 1. WEBSTER CATHETER # 1 AND THE 7 FRENCH GUIDING CATHETER WERE REMOVED FROM THE PATIENT¿S BODY. WEBSTER CATHETER # 2 WAS INSERTED, POSITIONED IN THE RIGHT VENTRICLE (RV), AND THE PROCEDURE CONTINUED. THERE WERE NO INJURIES AS A RESULT OF THE MEDICAL DEVICE ENTRAPMENT. IT WAS NOTED THAT THERE WAS A 2-HOUR DELAY IN THE PROCEDURE. LATER IN THE PROCEDURE, IT WAS DETERMINED THAT

    Patient problems: Arrhythmia; No Code Available

    MAUDE report 7073132 ↗

Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices

All CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices →