Skip to content

WEBSTER F6QA005CTRecalls & reported problems

Biosense Webster Inc · Class 2

All models of WEBSTER (29)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10846835007886), received between Nov 12, 2021 and Nov 12, 2021 — classified as 2 injuries.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Patient Device Interaction Problem2

Patient problems

  • Heart Block2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 12, 2021Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN ELECTROPHYSIOLOGY (EP) STUDY WITH TWO (2) WEBSTER¿ ELECTROPHYSIOLOGY CATHETER & TWO (2) WEBSTER ® CS CATHETER WITH EZ STEER® THECHNOLOGY AND AUTO ID AND THE PATIENT EXPERIENCED ATRIOVENTRICULAR (AV) HEART BLOCK REQUIRING PERMANENT PACEMAKER IMPLANTATION. DURING AN EP STUDY, THE PATIENT PRESENTED AV BLOCK OF 1 MINUTE. BACK-UP PACING WITH A CATHETER PLACED IN THE RIGHT VENTRICLE (RV) WAS POSSIBLE. AFTER A WAITING PERIOD UNDER PACING, THE PHYSICIAN TESTED IF THE AV CONDUCTION WAS BACK, BUT IT WAS NOT COMPLETELY. SO CONTINUOUS PACING FROM THE RV CATHETER WAS NECESSARY. THE PATIENT UNDERWENT THEN A CORONAROGRAPHY AND A PACING SONDE (TEMPORARY PACEMAKER) WAS IMPLANTED TO ENSURE BACK-UP PACING IN CASE OF AV BLOCK. THERE IS NO FURTHER INFORMATION ABOUT IF PROLONGED HOSPITALIZATION WAS REQUIRED. THE PHYSICIAN OPINION IS THAT IT IS NOT A COMPLICATION DUE TO THE PROCEDURE, BUT A PRE-EXISTING PATIENT-RELATED PROBLEM. NO ABLATION OR ABLATION CATHETER WAS IN USE AT ANY TIME. BASED ON THE INFORMATION INITIALLY PROVIDED, THIS EVENT WAS ASSESSED AS NOT MDR REPORTABLE BASED ON PHYSICIAN¿S OPINION INDICATING THIS WAS A PATIENT RELATED PRE-EXISTING CONDITION

    Patient problems: Heart Block

    MAUDE report 12806609 ↗
  • InjuryNov 12, 2021Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN ELECTROPHYSIOLOGY (EP) STUDY WITH TWO (2) WEBSTER¿ ELECTROPHYSIOLOGY CATHETER & TWO (2) WEBSTER ® CS CATHETER WITH EZ STEER® TECHNOLOGY AND AUTO ID AND THE PATIENT EXPERIENCED ATRIOVENTRICULAR (AV) HEART BLOCK REQUIRING PERMANENT PACEMAKER IMPLANTATION. DURING AN EP STUDY, THE PATIENT PRESENTED AV BLOCK OF 1 MINUTE. BACK-UP PACING WITH A CATHETER PLACED IN THE RIGHT VENTRICLE (RV) WAS POSSIBLE. AFTER A WAITING PERIOD UNDER PACING, THE PHYSICIAN TESTED IF THE AV CONDUCTION WAS BACK, BUT IT WAS NOT COMPLETELY. SO CONTINUOUS PACING FROM THE RV CATHETER WAS NECESSARY. THE PATIENT UNDERWENT THEN A CORONAROGRAPHY AND A PACING SONDE (TEMPORARY PACEMAKER) WAS IMPLANTED TO ENSURE BACK-UP PACING IN CASE OF AV BLOCK. THERE IS NO FURTHER INFORMATION ABOUT IF PROLONGED HOSPITALIZATION WAS REQUIRED. THE PHYSICIAN OPINION IS THAT IT IS NOT A COMPLICATION DUE TO THE PROCEDURE, BUT A PRE-EXISTING PATIENT-RELATED PROBLEM. NO ABLATION OR ABLATION CATHETER WAS IN USE AT ANY TIME. BASED ON THE INFORMATION INITIALLY PROVIDED, THIS EVENT WAS ASSESSED AS NOT MDR REPORTABLE BASED ON PHYSICIAN¿S OPINION INDICATING THIS WAS A PATIENT RELATED PRE-EXISTING CONDITION.

    Patient problems: Heart Block

    MAUDE report 12806522 ↗

FDA clearance and classification

The device record lists FDA submission K892265; its details are not in the openFDA clearance files we use.

The FDA regulates product code DRF (catheter, electrode recording, or probe, electrode recording) under 21 CFR 870.1220 as a Class II device. 21 CFR 870.1220 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the WEBSTER F6QA005CT

Has the WEBSTER F6QA005CT been recalled?

No FDA recall record in our data names this exact device identifier (DI 10846835007886), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the WEBSTER F6QA005CT?

The FDA's MAUDE database lists 2 adverse event reports for this device, received on Nov 12, 2021. In those reports, the most common specific device problem is “Patient Device Interaction Problem” (2); the most common patient problem is “Heart Block” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the WEBSTER F6QA005CT?

None of the reports are classified as deaths, 2 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the WEBSTER F6QA005CT, and is it still sold?

The FDA's device database lists Biosense Webster Inc as the company responsible for it (brand WEBSTER, model F6QA005CT). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices

All CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page