Sterile Interface Cable D133701Recalls & reported problems
Biosense Webster Inc · Cath to Generator CBL Sterile · Class 3
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10846835010121), received between May 29, 2026 and May 29, 2026 — classified as 1 malfunction.
The most frequently reported specific device problem is “Communication or Transmission Problem” (1 report).
1 other recall cover devices cleared under the same FDA submission (P240006); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Communication or Transmission Problem1
- Electrical Shorting1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 29, 2026Communication or Transmission Problem; Electrical Shorting
IT WAS REPORTED THAT A PATIENT UNDERWENT AN ATRIAL FIBRILLATION (AFIB) PROCEDURE WITH A STERILE INTERFACE CABLE AND A SIGNAL INTERFERENCE (NOISE/LOSS) ISSUE OBSERVED ON THE IC, BS, OR ALL ECG (BS + IC) CHANNELS ON ALL SYSTEMS AND THE EKG BECAME UNAVAILABLE FOR THE PHYSICIAN TO MONITOR THE PATIENT¿S HEART RHYTHM. INITIALLY IT WAS REPORTED THAT THERE WAS A "CURRENT LEAK" ALERT BEING DISPLAYED ON THE TRUPULSE¿ MONITOR. THEY REPLACED THE VARIPULSE¿ CATHETER CABLE (STERILE INTERFACE CABLE) AND THE ISSUE WAS RESOLVED. THE PROCEDURE CONTINUED. ADDITIONAL INFORMATION WAS RECEIVED ON 20-MAY-2026. A SIGNAL INTERFERENCE (NOISE/LOSS) ISSUE WAS OBSERVED ON THE INTRACARDIAC (IC), BODY SURFACE (BS), OR ALL ECG (BS + IC) CHANNELS ON ALL SYSTEMS. THE EKG BECAME UNAVAILABLE FOR THE PHYSICIAN TO MONITOR THE PATIENT¿S HEART RHYTHM. THE CATHETER WAS IN THE PATIENT¿S BODY. THE "CURRENT LEAK" ALERT EVENT WAS ORIGINALLY CONSIDERED NON-REPORTABLE, HOWEVER, BWI BECAME AWARE ON 20-MAY-2026 OF A SIGNAL INTERFERENCE (NOISE/LOSS) ISSUE OBSERVED ON THE IC, BS, OR ALL ECG (BS + IC) CHANNELS ON ALL SYSTEMS AND THE EKG BECAME UNAVAILABLE FOR THE PHYSICIAN TO MONITOR THE PATIENT¿S HEART RHYTHM AND HAVE ASSESSED THIS
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25337203 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P240006. One submission often covers many models, so check the product and lot details in each record.
- Z-1205-2025 · Jan 5, 2025 · CompletedVARIPULSE Bi-Directional Ablation Catheter REF D141201. The Field Catheter is indicated for use in catheter based cardiac electrophysiological mapping (stimulating and recordin
Other Percutaneous Cardiac Ablation Catheter for Treatment of Atrial Fibrillation with Irreversible Electroporation devices
- FARAWAVE™ M004PF41M401Boston Scientific Corporation · Percutaneous Cardiac Ablation Catheter for Treatment of Atrial Fibrillation with Irreversible Electroporation1 recall39 deaths1,515 reports
- PulseSelect™ PSCC100Medtronic, Inc. · Percutaneous Cardiac Ablation Catheter for Treatment of Atrial Fibrillation with Irreversible Electroporation3 deaths496 reports
- FARAWAVE™ NAV M004PF41M411Boston Scientific Corporation · Percutaneous Cardiac Ablation Catheter for Treatment of Atrial Fibrillation with Irreversible Electroporation11 deaths417 reports
- VARIPULSE™ Bi-Directional Catheter D141201Biosense Webster Inc · Percutaneous Cardiac Ablation Catheter for Treatment of Atrial Fibrillation with Irreversible Electroporation1 recall3 deaths273 reports
- FARAWAVE™ M004PF41M431Boston Scientific Corporation · Percutaneous Cardiac Ablation Catheter for Treatment of Atrial Fibrillation with Irreversible Electroporation11 deaths272 reports
- Sphere-9™ Catheter AFR-00001Medtronic, Inc. · Percutaneous Cardiac Ablation Catheter for Treatment of Atrial Fibrillation with Irreversible Electroporation1 recall15 reports
- FARAWAVE™ M004PF41M402Boston Scientific Corporation · Percutaneous Cardiac Ablation Catheter for Treatment of Atrial Fibrillation with Irreversible Electroporation2 deaths57 reports
- Volt™ PFA Sensor Enabled™ A-VOLT-01St. Jude Medical, Inc. · Percutaneous Cardiac Ablation Catheter for Treatment of Atrial Fibrillation with Irreversible Electroporation2 deaths38 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page