DTRAX Cervical Cage-B PD-31-200Recalls & reported problems
Providence Medical Technology, Inc. · The DTRAX Cervical Cage-B is a single-use, titanium alloy intervertebral implant available in various footprints and heights. It is intended to be used in cervical spinal fusion surgery for skeletally mature patients with degenerative disc disease of the cervical spine with accompanying radicular symptoms at one disc level. · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10852776006000), received between Feb 13, 2019 and Feb 13, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “Migration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Migration1
Patient problems
- Inadequate Pain Relief1
- Neck Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 13, 2019Adverse Event Without Identified Device or Use Problem; Migration; Adverse Event Without Identified Device or Use Problem; Migration
ON (B)(6) 2019 PATIENT CONTACTED PMT AND REPORTED THAT ON (B)(6) 2017, HE UNDERWENT A POSTERIOR FUSION PROCEDURE AT C3-C4, AND C4-C5 LEVELS, WITH PMT CAGES. HE ALSO REPORTED A POSSIBLE TRAUMATIC INCIDENT POST PROCEDURE AS WELL AS FRACTURES AT C2, C5 AND C6, AS WELL AS AND 3 CAGE MIGRATIONS. CURRENTLY, ALMOST TWO YEARS POST PROCEDURE, PATIENT REPORTS PAIN, BOTH IN THE ARM AND NECK, INCONTINENCE, ARM NUMBNESS AND TINGLING, DIFFICULTY TO MOVE HIS RIGHT HAND AND TENDENCY TO LOSE CONSCIOUSNESS UPON ABRUPT NECK TURNING.
Patient problems: Inadequate Pain Relief; Neck Pain
MAUDE report 8338075 ↗
Other Intervertebral Fusion Device With Bone Graft, Cervical devices
- ROI-C MC1005TLDR Spine Usa, Inc. · Intervertebral Fusion Device With Bone Graft, Cervical54 reports
- EIT CIF cage CUI8070SEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall4 reports
- EIT CIF cage CUI8060LEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall1 report
- CONSTRUX - MINI Ti 37-7212SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-8015SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-7206SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-8007SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI PTC 37-4211SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page