ISPAN SF6 Intraocular Gas 20 g CylinderRecalls & reported problems
Escalon Medical Corp. · ISPAN Sulfur Hexafluoride (SF6) is a liquified gas under pressure and is administered by injection into the vitreous cavity. It is a colorless, odorless, non-toxic, non-flammable gas. The boiling point is -63.9°C (-83°F) and the vapor pressure at 20°C is 320 psig (pounds per square inch gauge). ISPAN SF6 purity: sulfur hexafluoride 99.99% (minimum), air 100 ppm (maximum), carbon tetrafluoride 100 ppm (maximum), and hydrogen fluoride 0.3 ppm (maximum). · Class 3
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10860113000116), received between Apr 12, 2019 and Apr 12, 2019 — classified as 2 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Insufficient Device Problem Information2
Patient problems
- Retinal Detachment2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryApr 12, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
EVENT: CASE 2 OF 2. CUSTOMER REPORTED TO DISTRIBUTOR THAT THEY HAD BEEN USING A GAS CYLINDER OF SULFUR HEXAFLUORIDE SINCE (B)(6) 2017 WITH NO ISSUES BUT TWO RECENT CASES INVOLVING RETINA RE-ATTACHMENT HAD RE-DETACHED. NO FURTHER INFORMATION WAS PROVIDED NOT WERE ADDITIONAL REPORTS PROVIDED THAT PATIENTS EVENTUALLY HAD SUCCESSFUL REATTACHMENT OR NOT. NO INDIVIDUAL PATIENT INFORMATION IS KNOWN SUCH AS AGE, SEX, ETC. ON 2/27/2018, THE DISTRIBUTOR REPORTED THE CASE. THE ACTUAL DATE OF THE PATIENT EVENTS IS UNKNOWN OTHER THAN THAT THEY OCCURRED ON THE SAME DAY. THE PRODUCT WAS RETURNED TO MANUFACTURER. MANUFACTURER CONDUCTED A REVIEW OF THE BATCH PRODUCT RECORD AND DISCOVERED NO ISSUES. MANUFACTURER ALSO RE-ANALYZED THE CYLINDER OF GAS AND THE PRODUCT MET THE ORIGINAL SPECIFICATION.
Patient problems: Retinal Detachment
MAUDE report 8511389 ↗InjuryApr 12, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
EVENT: CASE 1 OF 2. CUSTOMER REPORTED TO DISTRIBUTOR THAT THEY HAD BEEN USING A GAS CYLINDER OF SULFUR HEXAFLUORIDE SINCE (B)(6) 2017 WITH NO ISSUES BUT TWO RECENT CASES INVOLVING RETINA RE-ATTACHMENT HAD RE-DETACHED. NO FURTHER INFORMATION WAS PROVIDED NOR WERE ADDITIONAL REPORTS PROVIDED THAT PATIENTS EVENTUALLY HAD SUCCESSFUL REATTACHMENT OR NOT. NO INDIVIDUAL PATIENT INFORMATION IS KNOWN SUCH AS AGE, SEX, ETC.. ON 2/27/2018, THE DISTRIBUTOR REPORTED THE CASE. THE ACTUAL DATE OF THE PATIENT EVENTS IS UNKNOWN OTHER THAN THAT THEY OCCURRED ON THE SAME DAY. THE PRODUCT WAS RETURNED TO MANUFACTURER. MANUFACTURER CONDUCTED A REVIEW OF THE BATCH PRODUCT RECORD AND DISCOVERED NO ISSUES. MANUFACTURER ALSO RE-ANALYZED THE CYLINDER OF GAS AND THE PRODUCT MET THE ORIGINAL SPECIFICATION.
Patient problems: Retinal Detachment
MAUDE report 8511384 ↗
Other Gases Used Within Eye To Place Pressure On Detached Retina devices
- ISPAN 8065797102Alcon Laboratories, Inc. · Gases Used Within Eye To Place Pressure On Detached Retina84 reports
- ISPAN 8065797103Alcon Laboratories, Inc. · Gases Used Within Eye To Place Pressure On Detached Retina38 reports
- ISPAN 8065797105Alcon Laboratories, Inc. · Gases Used Within Eye To Place Pressure On Detached Retina23 reports
- ISPAN 8065797005Alcon Laboratories, Inc. · Gases Used Within Eye To Place Pressure On Detached Retina10 reports
- ISPAN 8065797002Alcon Laboratories, Inc. · Gases Used Within Eye To Place Pressure On Detached Retina9 reports
- ISPAN 8065797004Alcon Laboratories, Inc. · Gases Used Within Eye To Place Pressure On Detached Retina1 report
- ISPAN C3F8 Intraocular Gas 20 g CylinderEscalon Medical Corp. · Gases Used Within Eye To Place Pressure On Detached Retina1 report
- ISPAN 8065797101Alcon Laboratories, Inc. · Gases Used Within Eye To Place Pressure On Detached Retina1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page