microTargeting™ Electrode FC2001-00749Recalls & reported problems

Fhc, Inc. · microTargeting Differential Electrode 5x, D.ZAP(L), Sterile, Array, T=30 for use with Frame, STar or MT Drive · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10873263007492), received between Feb 12, 2020 and Dec 1, 2023 — classified as 2 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2

Patient problems

  • Intracranial Hemorrhage2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 1, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    WHEN MER ON ONE SIDE WAS COMPLETED AND A TEST STIMULATION WAS USED, IT WAS CONFIRMED THAT THE LEFT SIDE OF THE BODY OPPOSITE TO THE RIGHT HEMISPHERE WHERE MER WAS PERFORMED COULD NOT BE MOVED AS THE PATIENT WANTED IT TO. THE PATIENT'S RESPONSE WAS NOT CLEAR AND THE PATIENT'S CONDITION WAS STRANGE, SO A DBS OPERATION WAS DISCONTINUED, AND WHEN A CT SCAN WAS PERFORMED; A HEMORRHAGE IN THE BRAIN WAS CONFIRMED. SUBSEQUENTLY, THE BLOOD WAS REMOVED VIA EMERGENCY CRANIOTOMY. THE PROGRESS HAS NOT BEEN CONFIRMED YET. THE PRODUCT WAS DISCARDED AND LOT NUMBER IS UNKNOWN. THE DOCTOR HAS CONFIRMED THERE WAS NO ISSUE WITH OUR PRODUCT, THIS HAPPENS AS A SIDE EFFECT OF BRAIN SURGERY.

    Patient problems: Intracranial Hemorrhage

    MAUDE report 18245509 ↗
  • InjuryFeb 12, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AN EVENT AT HOSPITAL IN (B)(6) INVOLVING FHC PRODUCT MODEL FC2001 ON (B)(6) 2020. EVENT WAS DESCRIBED AS FOLLOWS: "AT THE TIME OF INTRAOPERATIVE STIMULATION, THERE WAS ABNORMALITY IN THE PATIENT'S CONDITION. THE PRODUCT WAS EXTRACTED IMMEDIATELY AND IT WAS DISCONTINUED. AFTER THAT, CT SCAN WAS PERFORMED. INTRACEREBRAL HEMORRHAGE OCCURRED DURING INTRAOPERATIVE STIMULATION. THE PATIENT WAS IN THE CONDITION OF UPPER LIMB HEMIPLEGIA." REPORT NOTES THAT THE PATIENT IS ALIVE-WITH INJURY AND THIS WAS A FACTOR OF SURGICAL PROCEDURE. THE REPORT ALSO NOTES THAT THE EVENT HAD NO RELATION WITH THE PRODUCT. PRODUCT WAS DISCARDED BY USER AND WAS NOT RETURNED TO THE MANUFACTURER FOR EVALUATION.

    Patient problems: Intracranial Hemorrhage

    MAUDE report 9699816 ↗

Other ELECTRODE, DEPTH devices

All ELECTRODE, DEPTH devices →