Argyle 8888413823Recalls & reported problems
Mozarc Medical US LLC · Peritoneal Dialysis Catheter Kit, Swan Neck Curl Cath, 2 Cuffs Left · Class 2 · Implant
All models of Argyle (36)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10884521004634), received between Jun 30, 2020 and Mar 28, 2025 — classified as 2 injuries, 4 malfunctions.
The most frequently reported specific device problem is “Break” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break3
- Detachment of Device or Device Component1
- Infusion or Flow Problem1
- Leak/Splash1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- Foreign Body In Patient2
- Insufficient Information2
- Radiation Exposure, Unintended1
- Unintended Radiation Exposure1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 28, 2025Leak/Splash; Leak/Splash
ACCORDING TO THE REPORTER, IT WAS OBSERVED THAT THE CATHETER WAS LEAKING WHEN IT WAS TAKEN OUT FROM THE PATIENT AS PER THE SURGEON. IT WAS STATED THAT THE PERITONEAL DIALYSIS CATHETER (PDC) HAD THE SECONDARY STRUCTURAL FAILURE, NUMEROUS PINHOLE LEAKS. AS A REMEDIAL AND INTERVENTION, THE CATHETER WAS REMOVED DURING THE FOLLOW-UP SURGERY. THE PRODUCT WAS NOT REPLACED. THERE WAS NO REPORTED PATIENT OUTCOME.
Patient problems: Insufficient Information
MAUDE report 21726330 ↗InjuryAug 22, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
ACCORDING TO THE REPORTER, THE CATHETER WAS PLACED ON THE LEFT SIDE OF THE PATIENT¿S ABDOMEN. DURING A DIALYSIS CATHETER REMOVAL, IT WAS CONFIRMED TO BE A PD CATHETER. THE DOCTOR SHOWED THE REMOVED CATHETER, AND BOTH CUFFS WERE MISSING. IT WAS STATED THAT THE CUFFS HAD BEEN ATTACHED TO THE CATHETER CANNULA. BOTH VERIFIED THAT THE DEVICE WAS NOT EXPIRED. A DISCUSSION WAS HAD BETWEEN THE DOCTORS ON HOW INVASIVE IT WOULD BE TO REMOVE THE CUFFS. THE PATIENT HAD NOT CONSENTED TO GENERAL ANESTHESIA. THEY WERE ABLE TO RETRIEVE ONE CUFF THROUGH THE EXISTING INCISION BUT NOT THE SECOND, AS THE PATIENT WAS BECOMING UNCOMFORTABLE WHILE SEARCHING TO FIND IT. THEY DECIDED TO LEAVE THE SECOND CUFF AND END THE PROCEDURE. THE CUFF THAT WAS REMOVED APPEARED TO BE INTACT, AND IT REQUIRED SOME CUTTING TO BE REMOVED FROM THE TISSUE. THERE WAS MINIMAL BLOOD LOSS DURING THE PROCEDURE, AND IT WAS REPORTED TO BE 5 ML OF BLOOD LOSS. NO X-RAY WAS PERFORMED. IT WAS STATED THAT THE DEVICE WAS EASILY EVACUATED; THERE WAS NO TENSION. IT WAS ALSO STATED THAT NO PORTION OF THE CUFF REMAINED ON THE CATHETER. NO OTHER DAMAGE WAS NOTED OTHER THAN THE MISSING CUFFS. THE REASON FOR THE REMOVAL OF THE DEVICE WAS THAT I
Patient problems: Foreign Body In Patient
MAUDE report 20039821 ↗MalfunctionMay 23, 2024Break; Break
ACCORDING TO THE REPORTER, DURING INSERTION PROCEDURE, A PIECE WHICH WAS CLEAR PLASTIC RING OF THE PD (PERITONEAL DIALYSIS) CATHETER BROKE OFF. THE CATHETER WAS NOT REPAIRED. THERE WAS NO LEAK. THERE WAS NO LUER ADAPTER ISSUE. THE INSERTION SITE WAS TREATED PRIOR TO PRODUCT PLACEMENT. NOTHING UNUSUAL OBSERVED ON THE DEVICE PRIOR TO USE. IT WAS SOAKED IN NORMAL SALINE. THE RESULT OF FLUSHING PRIOR TO USE WAS NORMAL. NO OTHER PRODUCTS BEING UTILIZED WITH THE DEVICE. NO CLEANING AGENT USED ON THE DEVICE. NO OTHER DEFECTS/DAMAGES FOUND ON THE PRODUCT. THE INSERTION SITE WAS PREPPED WITH HIBICLENS PRIOR TO PRODUCT PLACEMENT. THE PRODUCT WAS NEVER IMPLANTED. PHYSICIAN WAS ABLE TO REMOVE PIECES IMMEDIATELY VIA LAPAROSCOPIC GRASPER AND REPLACE IT WITH A NEW PD CATHETER. THE PROCEDURE WAS COMPLETED AFTER RESOLVING THE ISSUE. THERE WAS NO BLOOD LOSS. BLOOD TRANSFUSION WAS NOT REQUIRED. NO MEDICAL INTERVENTION/MEDICAL TREATMENT REQUIRED AS THE RESULT OF THE EVENT. THE PATIENT TREATED UNDER GENERAL ANESTHESIA AND THE ANESTHESIA TIME WAS NOT EXTENDED BY GREATER THAN 30 MINUTES. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19387902 ↗MalfunctionMar 23, 2021Break; Break
ACCORDING TO THE REPORTER, A LEAK HAD DEVELOPED NEAR TO CATHETER EXIT SITE WHERE A CRACK OBSERVED OVER A YEAR AFTER INSERTION. THE CATHETER WAS NOT REPAIRED. POVIDONE IODINE WAS THE CLEANING AGENT USED ON THE DEVICE. TEGO WAS NOT UTILIZED AND THERE WAS NO LUER ADAPTER ISSUE. THE INSERTION SITE WAS CLEANSED WITH IODINE PRIOR TO PRODUCT PLACEMENT. NO OTHER PRODUCTS BEING UTILIZED WITH THE DEVICE. THE TREATMENT WAS BY PRESCRIPTION. BACTROBAN OINTMENT WAS UTILIZED AS THE EXIT SITE. ADHESIVE DRESSING CALLED COSMOPORE WAS USED AS THE WOUND DRESSING AND IT DID NOT INCLUDE ANY CLEANING AGENTS OR ANTIMICROBIAL PROPERTIES. THE CLEANING AGENT WAS ALLOWED TO DRY THOROUGHLY PRIOR TO DRESSING THE AREA AND PRIOR TO APPLYING OINTMENT TO THE AREA. THE PATIENT WAS RESPONSIBLE FOR ANY TYPE OF CATHETER MAINTENANCE AND WOULD DO DAILY PD CATHETER EXIT SITE DRESSING WITH IODINE SWABSTICK. THE CLEANING AGENT HAD NEVER SWITCHED OVER THE LIFE OF THE CATHETER AND IT HAD NEVER MIXED. THE SITE HAD NEVER USED SEPSIDERM TO CLEAN CATHETERS. THERE WAS NO PROTOCOL CHANGE FOR CLEANING AGENT USED RECENTLY. THE PATIENT THEMSELVES WAS NOT USING ANY TYPE OF CLEANING AGENT OR ANTIBIOTIC ON THE CATHETERS. FLUSHING WAS DON
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 11558926 ↗MalfunctionFeb 16, 2021Infusion or Flow Problem; Infusion or Flow Problem
ACCORDING TO THE REPORTER, DURING USE, IT WAS STATED THAT THE PATIENT HAD A DRAINAGE PROBLEM DUE TO THE CATHETER. THE CAREGIVERS PRESCRIBED A FLUCTUATING MODALITY TO THE PATIENT IN ORDER TO ALLEVIATE THESE DRAINAGE PROBLEMS. IT WAS STATED THAT THE LINES ARE NOT PINCHED, STUCK OR BLOCKED AND WAS IN THE RIGHT PLACE OF THE ABDOMEN. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11331418 ↗InjuryJun 30, 2020Break; Break
ACCORDING TO THE REPORTER, WHEN THE CATHETER WAS IMPLANTED IN THE PATIENT, THERE WERE NO ANY COMPLICATIONS AND THE PATIENT WAS RELEASED FROM THE HOSPITAL. APPROXIMATELY TWO (2) WEEKS LATER, WHEN THE PATIENT RETURNED FOR A FOLLOW-UP VISIT, THE CATHETER WAS NOT ABLE TO BE FLUSHED WHEN REGULAR HEPARIN WAS INFUSED. IT WAS ALSO STATED THAT CONTRAST POOLED WAS NOTED IN THE SUBCUTANEOUS TISSUE. WHEN THEY FAILED TO LOCATE THE DISTAL END OF THE CATHETER, A CT (COMPUTED TOMOGRAPHY) SCAN WAS ORDERED. IT REVEALED THAT THE CATHETER WAS BROKEN INTO TWO PIECES AND THE PATIENT WAS TAKEN INTO THE SURGERY TO REMOVED THE BROKEN DEVICE.
Patient problems: Foreign Body In Patient; Radiation Exposure, Unintended; Unintended Radiation Exposure
MAUDE report 10211317 ↗
Other CATHETER, PERITONEAL, LONG-TERM INDWELLING devices
- Argyle 8811313010Mozarc Medical US LLC · CATHETER, PERITONEAL, LONG-TERM INDWELLING1 death75 reports
- Aspira Drainage Kit 4992301Bard Access Systems, Inc. · CATHETER, PERITONEAL, LONG-TERM INDWELLING1 recall4 reports
- Flex-Neck® 00884450170069Merit Medical Systems, Inc. · CATHETER, PERITONEAL, LONG-TERM INDWELLING1 recall0 reports
- Flex-Neck® 00884450305850Merit Medical Systems, Inc. · Catheter, peritoneal, long-term indwelling1 recall0 reports
- Argyle 8888415604Mozarc Medical US LLC · Catheter, peritoneal, long-term indwelling48 reports
- Argyle 8888423103Mozarc Medical US LLC · Catheter, Peritoneal, Long-Term Indwelling42 reports
- Argyle 8888411405Mozarc Medical US LLC · CATHETER, PERITONEAL, LONG-TERM INDWELLING33 reports
- Argyle 8888413807Mozarc Medical US LLC · CATHETER, PERITONEAL, LONG-TERM INDWELLING16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page