Argyle 8888413831Recalls & reported problems
Mozarc Medical US LLC · Peritoneal Dialysis Catheter Kit, Swan Neck Curl Cath, 2 Cuffs Right · Class 2 · Implant
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10884521004641), received between Apr 23, 2020 and Jul 3, 2025 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
- Detachment of Device or Device Component1
- Product Quality Problem1
Patient problems
- No Consequences Or Impact To Patient2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 3, 2025Product Quality Problem; Detachment of Device or Device Component; Product Quality Problem; Detachment of Device or Device Component
ACCORDING TO THE REPORTER, THE INTRODUCER NEEDLE THAT WAS IN THE KIT SNAPPED AT THE NEEDLE WHEN IT WAS BEING INTRODUCED INTO THE PATIENT'S ABDOMEN THROUGH A SURGICAL INCISION. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22401370 ↗MalfunctionApr 23, 2020Break; Break
ACCORDING TO THE REPORTER, DURING THE PLACEMENT OF THE INITIAL PD (PERITONEAL DIALYSIS) CATHETER AFTER TUNNELING WAS DONE, THE PHYSICIAN FLUSHED THE PRODUCT AND A LEAK BETWEEN THE CATHETER CUFFS WAS NOTED. IT WAS SAID THAT THE HEALTH CARE PROVIDER (HCP) THEN EXPOSED THE DEVICE FROM THE TUNNEL AND FOUND A HOLE. IT WAS SAID THAT NO CLEANING AGENT WAS USED, TEGO WAS NOT UTILIZED AND THERE WAS NO LUER ADAPTER ISSUE. IT WAS HOWEVER REPORTED THAT THE INSERTION SITE WAS TREATED WITH CHLORHEXIDINE TO PREP THE PATIENT'S SKIN PRIORTO PRODUCT PLACEMENT. PRIOR TO USE, IT WAS REPORTED THAT THE PACKAGE WAS STILL SEALED UPON RECEIPT. VISUAL INSPECTION WAS DONE RIGHT AFTER THE PRODUCT WAS TAKEN OUT OF THE PACKAGE AND NO DEFECT OR UNUSUAL OBSERVED WITH THE DEVICE. FLUSHING WAS DONE AND NO ISSUES WERE NOTED. IT WAS ALSO SAID THAT CLAMP WAS NOT USED DURING THE CATHETER INSERTION. THEN DURING THE PLACEMENT OF THE SECOND PD CATHETER (REPLACEMENT), SAME PROCEDURE (FLUSHING, VISUAL INSPECTION AND SKIN PREP) WAS DONE PRIOR TO USE AND WITH NO UNUSUAL RESULTS. IT WAS MENTIONED THAT WHILE THE HCP WAS IN THE PROCESS OF FEEDING THE CATHETER INTO THE GUIDE WIRE THROUGH THE PULL APART SHEATH, THE PRODUCT WAS OBS
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9989278 ↗MalfunctionApr 23, 2020Break; Break
ACCORDING TO THE REPORTER, DURING THE PLACEMENT OF THE INITIAL PD (PERITONEAL DIALYSIS) CATHETER AFTER TUNNELING WAS DONE, THE PHYSICIAN FLUSHED THE PRODUCT AND A LEAK BETWEEN THE CATHETER CUFFS WAS NOTED. IT WAS SAID THAT THE HEALTH CARE PROVIDER (HCP) THEN EXPOSED THE DEVICE FROM THE TUNNEL AND FOUND A HOLE. IT WAS SAID THAT NO CLEANING AGENT WAS USED, TEGO WAS NOT UTILIZED AND THERE WAS NO LUER ADAPTER ISSUE. IT WAS HOWEVER REPORTED THAT THE INSERTION SITE WAS TREATED PRIOR TO PRODUCT PLACEMENT. THEN DURING THE PLACEMENT OF THE SECOND PD CATHETER (REPLACEMENT), IT WAS MENTIONED THAT WHILE THE HCP WAS IN THE PROCESS OF FEEDING THE CATHETER INTO THE GUIDE WIRE THROUGH THE PULL APART SHEATH, THE PRODUCT WAS OBSERVED TO HAVE BROKEN IN TWO PIECES AT THE BASE OF THE "SUB Q" CUFF. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9989268 ↗
Other CATHETER, PERITONEAL, LONG-TERM INDWELLING devices
- Argyle 8811313010Mozarc Medical US LLC · CATHETER, PERITONEAL, LONG-TERM INDWELLING1 death75 reports
- Aspira Drainage Kit 4992301Bard Access Systems, Inc. · CATHETER, PERITONEAL, LONG-TERM INDWELLING1 recall4 reports
- Flex-Neck® 00884450305850Merit Medical Systems, Inc. · Catheter, peritoneal, long-term indwelling1 recall0 reports
- Flex-Neck® 00884450170069Merit Medical Systems, Inc. · CATHETER, PERITONEAL, LONG-TERM INDWELLING1 recall0 reports
- Argyle 8888415604Mozarc Medical US LLC · Catheter, peritoneal, long-term indwelling48 reports
- Argyle 8888423103Mozarc Medical US LLC · Catheter, Peritoneal, Long-Term Indwelling42 reports
- Argyle 8888411405Mozarc Medical US LLC · CATHETER, PERITONEAL, LONG-TERM INDWELLING33 reports
- Argyle 8888413807Mozarc Medical US LLC · CATHETER, PERITONEAL, LONG-TERM INDWELLING16 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.