Permcath 8831692001Recalls & reported problems

Mozarc Medical US LLC · Chronic Silicone Oval Catheter Kit Staggered Tip · Class 2 · Implant

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10884521009882), received between Oct 20, 2023 and Oct 20, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 20, 2023Break; Break

    ACCORDING TO THE REPORTER, AT 15:30, THE DOCTOR WAS REPLACING THE HEMODIALYSIS TUBE AND ACCESSORIES OF THE PATIENT. NEAR THE END OF THE OPERATION, WHEN PREPARING TO CONNECT THE LUER ADAPTER (STERILE INFUSION CONNECTOR) TO THE PATIENT, IT WAS DISCOVERED THAT ONE OF THE LUER ADAPTERS WAS DAMAGED. THE VENOUS/BLUE LUER ADAPTER HAD A CRACK AND A LEAK WAS OBSERVED IN THE CRACKED AREA. THE PATIENT'S PULSE RATE PER MINUTE WAS 80 TIMES/MINUTE, BREATH RATE PER MINUTE WAS 19 TIMES/MINUTE AND BP (BLOOD PRESSURE) WAS 140/85MMHG. THE PATIENT DID NOT COMPLAIN OF DISCOMFORT. TEGO WAS UTILIZED AND THE CATHETER WAS REPAIRED. THERE WAS NO CLEANING AGENT USED ON THE DEVICE. IODOPHOR WAS THE CLEANING AGENT UTILIZED TO CLEAN THE ADAPTERS. THE DEVICE WAS NOT REPLACED WITH A NEW PRODUCT AND THE CATHETER WAS NOT EXPLANTED. THE CLEANING AGENT WAS ALLOWED TO DRY THOROUGHLY PRIOR TO APPLYING OINTMENT TO THE AREA. THERE WAS NOTHING UNUSUAL OBSERVED ON THE DEVICE PRIOR TO USE AND THERE WERE NO OTHER PRODUCTS UTILIZED WITH THE DEVICE. A SALINE WAS USED TO FLUSH THE DEVICE PRIOR TO USE AND HAD NO ISSUES. THEY IMMEDIATELY REPLACED THE LUER ADAPTER WITH A SPARE LUER ADAPTER OR DISPOSABLE STERILE INFUSION CONNECTOR

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17980922 ↗