Polysorb L-2752KRecalls & reported problems
Covidien LP · Braided Absorbable Suture · Class 2 · Implant
All models of Polysorb (291)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10884521046559), received between Jul 6, 2017 and Feb 15, 2021 — classified as 2 injuries, 1 malfunction.
The most frequently reported specific device problem is “Break” (3 reports).
2 other recalls cover devices cleared under the same FDA submission (K963253, K981935); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break3
- Dull, Blunt2
Patient problems
- Tissue Damage2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 15, 2021Break; Break
ACCORDING TO THE REPORTER, ON AN OPHTHALMOLOGICAL PROCEDURE, THE SUTURE BROKE QUICKLY AND BECAME LINT. ANOTHER DEVICE WAS USED TO COMPLETE THE CASE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11327229 ↗InjuryJul 6, 2017Break; Dull, Blunt; Break; Dull, Blunt
ACCORDING TO THE REPORTER, DURING A SQUINT PROCEDURE THE USED DEVICE NEEDLE BROKE. WHEN USING THE DEVICE TO SUTURE THE CONJUNCTIVA AND THE SURROUNDING MUSCLES, THE NEEDLE DID NOT PASS THROUGH THE TISSUE EASILY AND THE SURGEON HAD TO USE FORCE TO PASS THE POINT OF THE NEEDLE. THIS ISSUE OCCURRED WITH 5 SUTURES EACH FROM 2 DIFFERENT LOTS (TOTAL OF 10 SUTURES). THE SURGICAL TIME WAS EXTENDED MORE THAN 30 MINUTES AND THERE WAS TISSUE DAMAGE AND LOSS AS A RESULT OF THIS COMPLAINT. THE EXTENT OF THE TISSUE DAMAGE AND LOSS WILL NOT BE MADE AVAILABLE. NO ADDITIONAL OPERATION WILL BE NEEDED. THE PATIENT STATUS IS LISTED AS ALIVE WITH NO INJURY.
Patient problems: Tissue Damage
MAUDE report 6689218 ↗InjuryJul 6, 2017Break; Dull, Blunt; Break; Dull, Blunt
ACCORDING TO THE REPORTER, DURING A SQUINT PROCEDURE THE USED DEVICE NEEDLE BROKE. WHEN USING THE DEVICE TO SUTURE THE CONJUNCTIVA AND THE SURROUNDING MUSCLES, THE NEEDLE DID NOT PASS THROUGH THE TISSUE EASILY AND THE SURGEON HAD TO USE FORCE TO PASS THE POINT OF THE NEEDLE. THIS ISSUE OCCURRED WITH 5 SUTURES EACH FROM 2 DIFFERENT LOTS (TOTAL OF 10 SUTURES). THE SURGICAL TIME WAS EXTENDED MORE THAN 30 MINUTES AND THERE WAS TISSUE DAMAGE AND LOSS AS A RESULT OF THIS COMPLAINT. THE EXTENT OF THE TISSUE DAMAGE AND LOSS WILL NOT BE MADE AVAILABLE. NO ADDITIONAL OPERATION WILL BE NEEDED. THE PATIENT STATUS IS LISTED AS ALIVE WITH NO INJURY.
Patient problems: Tissue Damage
MAUDE report 6689193 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K963253, K981935. One submission often covers many models, so check the product and lot details in each record.
- Z-2601-2018 · Jun 15, 2018 · TerminatedPolysorb Braided Absorbable Suture 1 36" 90 cm Undyed GS-21, Product Number CL-955
- Z-2541-2017 · May 3, 2017 · TerminatedSutures. POLYSORB: POLSORB 0 18 U/D PRECUT 126R, Item Number: L4; POLSORB 0 18 VIO PRECUT 226T; Item Number: L14; POLSORB 0 30 VIO PRECUT 227C, Item Number: L404; POLSORB 1 18 VI
Other SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC ACID devices
- Coated VICRYL VCP433HEthicon, LLC · SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC ACID1 death1,093 reports
- Polysorb CL-915Covidien LP · SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC ACID503 reports
- Coated VICRYL VCP493HEthicon, LLC · SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC ACID435 reports
- V-Loc 180 VLOCL0316Covidien LP · SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC ACID1 recall376 reports
- Coated VICRYL VCP345HEthicon, LLC · SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC ACID1 death405 reports
- V-Loc 180 VLOCL0604Covidien LP · SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC ACID1 recall328 reports
- V-Loc 180 VLOCA008LCovidien LP · SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC ACID1 recall294 reports
- V-Loc 180 VLOCL0326Covidien LP · SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC ACID330 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page