MAHURKAR Elite 8888221216Recalls & reported problems

Mozarc Medical US LLC · Acute Dual Lumen Catheter Kit,Straight Extensions,12 Fr/Ch (4.0 mm) x 16 cm · Class 2

All models of MAHURKAR Elite (64)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10884521125728), received between Jul 1, 2020 and Jan 29, 2026 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Insufficient Flow or Under Infusion” (1 report).

2 other recalls cover devices cleared under the same FDA submission (K120674); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Flow or Under Infusion1
  • Migration or Expulsion of Device1

Patient problems

  • Insufficient Information1
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 29, 2026Insufficient Flow or Under Infusion

    ACCORDING TO THE REPORTER, WITHIN 48 HOURS OF INSTALLATION, THE CATHETER HAD DYSFUNCTION DUE TO HIGH-PRESSURE PROBLEMS. THIS RESULTED IN INADEQUATE BLOOD FLOW AND POOR DIALYSIS. THE CATHETER WAS NOT REPAIRED. TEGO WAS NOT UTILIZED. THERE WAS NO LUER ADAPTER ISSUE. REINSTALLING THE CATHETER WAS THE IMMEDIATE ACTION. NO MEDICAL OR SURGICAL INTERVENTION WAS NEEDED TO PREVENT A PERMANENT IMPAIRMENT OF A FUNCTION. THE EVENT DID NOT LEAD TO OR EXTEND PATIENT HOSPITALIZATION. THERE WAS NO REPORTED PATIENT OUTCOME.

    Patient problems: Insufficient Information

    MAUDE report 24211418 ↗
  • MalfunctionJul 1, 2020Migration or Expulsion of Device; Migration or Expulsion of Device

    ACCORDING TO THE REPORTER, THE CATHETER SLID OUT OF THE SECUREMENT WING AND ONTO THE FLOOR. THE SECURING DEVICE WAS STILL SUTURED IN PLACE WITH BOTH SUTURES INTACT AND THE CATHETER WAS ALSO INTACT WHEN IT SLID OUT OF THE HOLDER. THE CATHETER WAS NOT REPAIRED AND THERE WAS NO LEAK. CHLORHEXIDINE WAS ROUTINELY USED TO CLEAN THE CENTRAL LINE SITES AND TEGO WAS NOT UTILIZED. THERE WAS NO LUER ADAPTER ISSUE. THERE WAS NOTHING UNUSUAL OBSERVED ON THE DEVICE PRIOR TO USE AND CONTINUOUS RENAL REPLACEMENT THERAPY (CRRT) BLOODLINES WAS BEING UTILIZED WITH THE DEVICE. THERE WERE NO OTHER DEFECTS/DAMAGES FOUND ON THE PRODUCT. THE DEVICE WAS NOT RETAINED. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10217457 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K120674. One submission often covers many models, so check the product and lot details in each record.

  • Z-2319-2026 · Apr 29, 2026 · Open, Classified
    Mahurkar Elite PASS Trays; Description (Product Number/CFN): 12 FR x 13cm Acute Dual Lumen Catheter with Straight Extensions, PASS Tray (8888221413), 12 FR x 16cm Acute Dual Lumen
  • Z-1007-2018 · Oct 14, 2017 · Terminated
    MAHURKAR"* Elite 12 FR x 16cm Acute Dual Lumen Dialysis Catheter with Curved Extensions, IC Trays. Product Number: 8888222316.

Other CATHETER, HEMODIALYSIS, NON-IMPLANTED devices