MAHURKAR Elite 8888233220Recalls & reported problems
Mozarc Medical US LLC · Acute Triple Lumen Catheter Kit Curved Extensions · Class 2
All models of MAHURKAR Elite (64)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10884521127685), received between Mar 7, 2024 and Sep 12, 2024 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Difficult to Remove” (2 reports).
2 other recalls cover devices cleared under the same FDA submission (K120674); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Difficult to Remove2
- Obstruction of Flow2
- Material Puncture/Hole1
Patient problems
- Insufficient Information2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 12, 2024Material Puncture/Hole; Material Puncture/Hole
ACCORDING TO THE REPORTER, DURING THE INSERTION PROCEDURE, THE CUSTOMER INSTALLED THE CATHETER AND NOTICED BLOOD LEAKAGE IN THE EXTENSION PROXIMALLY UNDER THE CLAMP. IT HAPPENED AT THE ANESTHESIOLOGIST DEPARTMENT. THE CATHETER WAS NOT REPAIRED. THERE WAS NO LUER ADAPTER ISSUE. TEGO WAS NOT UTILIZED. THE INSERTION SITE WAS TREATED PRIOR TO PRODUCT PLACEMENT. NOTHING UNUSUAL WAS OBSERVED ON THE DEVICE PRIOR TO USE. THERE WAS AN OBSERVATION OF FLUID LEAKAGE FROM THE CVK LEG (TRIPLE LUMEN CATHETER AND IT¿S THE MIDDLE LEG FOR I.V FLUIDS ) JUST INFERIOR TO THE LUER LOCK (LUER ADAPTER). THE LEAK WAS LOCATED JUST PROXIMAL FROM THE LUER ADAPTER. NO REPORT ON THE REASON FOR THE LEAKAGE. NO OTHER PRODUCTS WERE UTILIZED WITH THE DEVICE. THE CATHETER WAS REPLACED WITH A CATHETER FROM THE SAME SUPPLIER. THERE WAS NO CLEANING AGENT USED ON THE DEVICE. THE REMEDIAL ACTION PERFORMED WAS THE PLACEMENT OF A TRIPLE LUMEN DIALYSIS CATHETER AND THE PROCEDURE WAS COMPLETED. THERE WAS NO BLOOD LOSS, AND BLOOD TRANSFUSION WAS NOT REQUIRED. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20200945 ↗MalfunctionMar 8, 2024Difficult to Remove; Obstruction of Flow; Difficult to Remove; Obstruction of Flow
ACCORDING TO THE REPORTER, DURING THE PROCEDURE, BOTH CATHETERS HAD A PROBLEM WITH THE GUIDE SO IT COULD NOT INSERT THEM. IT WAS STATED THAT THE TWO CATHETERS WERE USED ON THE SAME PATIENT AND SAME DAY OF THE EVENT. WHEN THE CATHETER WANTED TO INSERT, THE PHYSICIAN TRIED TO FLUSH THE CATHETER TO PULL IT OVER THE GUIDEWIRE. HOWEVER, THE PHYSICIAN CANNOT USE THE THIRD LUMEN TO FLUSH AND TO PULL IN THE GUIDEWIRE. THERE WAS NO LEAK AND THERE WAS NO LUER ADAPTER ISSUE. THERE WAS NOTHING UNUSUAL OBSERVED ON THE DEVICE PRIOR TO USE AND THERE WERE NO OTHER VISIBLE DEFECTS/DAMAGE TO THE PRODUCTS AT THE TIME OF THE EVENT. THE CATHETER WAS NOT REPAIRED. TEGO WAS NOT UTILIZED. OCTENIDERM AND SODIUM CHLORIDE (NACL) WERE USED AS CLEANING AGENTS TO THE DEVICE. AS A REMEDIAL ACTION, A NEW CATHETER WITH THE SAME LOT WAS TAKEN. THE PROCEDURE WAS COMPLETED. THERE WAS NO REPORTED PATIENT OUTCOME.
Patient problems: Insufficient Information
MAUDE report 18867703 ↗MalfunctionMar 7, 2024Difficult to Remove; Obstruction of Flow; Difficult to Remove; Obstruction of Flow
ACCORDING TO THE REPORTER, DURING THE PROCEDURE, BOTH CATHETERS HAD A PROBLEM WITH THE GUIDE SO IT COULD NOT INSERT THEM. IT WAS STATED THAT THE TWO CATHETERS WERE USED ON THE SAME PATIENT AND SAME DAY OF THE EVENT. WHEN THE CATHETER WANTED TO INSERT, THE PHYSICIAN TRIED TO FLUSH THE CATHETER TO PULL IT OVER THE GUIDEWIRE. HOWEVER, THE PHYSICIAN CANNOT USE THE THIRD LUMEN TO FLUSH AND TO PULL IN THE GUIDEWIRE. THERE WAS NO LEAK AND THERE WAS NO LUER ADAPTER ISSUE. THERE WAS NOTHING UNUSUAL OBSERVED ON THE DEVICE PRIOR TO USE AND THERE WERE NO OTHER VISIBLE DEFECTS/DAMAGE TO THE PRODUCTS AT THE TIME OF THE EVENT. THE CATHETER WAS NOT REPAIRED. TEGO WAS NOT UTILIZED. OCTENIDERM AND SODIUM CHLORIDE (NACL) WERE USED AS CLEANING AGENTS TO THE DEVICE. AS A REMEDIAL ACTION, A NEW CATHETER WITH THE SAME LOT WAS TAKEN. THE PROCEDURE WAS COMPLETED. THERE WAS NO REPORTED PATIENT OUTCOME.
Patient problems: Insufficient Information
MAUDE report 18862302 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K120674. One submission often covers many models, so check the product and lot details in each record.
- Z-2319-2026 · Apr 29, 2026 · Open, ClassifiedMahurkar Elite PASS Trays; Description (Product Number/CFN): 12 FR x 13cm Acute Dual Lumen Catheter with Straight Extensions, PASS Tray (8888221413), 12 FR x 16cm Acute Dual Lumen
- Z-1007-2018 · Oct 14, 2017 · TerminatedMAHURKAR"* Elite 12 FR x 16cm Acute Dual Lumen Dialysis Catheter with Curved Extensions, IC Trays. Product Number: 8888222316.
Other CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED devices
- Power-Trialysis catheter 5605150Bard Access Systems, Inc. · CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED2 recalls13 reports
- Power-Trialysis catheter 5605240Bard Access Systems, Inc. · CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED2 recalls8 reports
- MAHURKAR 8888101002HPMozarc Medical US LLC · CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED2 recalls1 death8 reports
- Power-Trialysis Slim-Cath catheter 5855240Bard Access Systems, Inc. · CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED2 recalls4 reports
- Power-Trialysis catheter 5615200Bard Access Systems, Inc. · CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED2 recalls4 reports
- MAHURKAR 8888101003HPMozarc Medical US LLC · CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED2 recalls4 reports
- MAHURKAR 8888102003HPMozarc Medical US LLC · CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED2 recalls4 reports
- MAHURKAR 8888102004HPMozarc Medical US LLC · CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED2 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page