Symbotex SYM1510Recalls & reported problems
Sofradim Production · Composite Mesh,Monofilament Polyester with Absorbable Collagen Film and Marking · Class 2 · Implant
All models of Symbotex (31)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
Quick summary
This Sofradim Symbotex hernia mesh has 261 adverse event reports, including 257 injuries, 2 malfunctions and 2 deaths. Reports mostly describe hernia recurrence, pain, adhesions, and mesh migration, and several describe revision surgery or removal of the mesh. The count fell in the most recent 12 months, with 7 reports compared with 14 in the 12 months before. There are no recalls that name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 261
- Deaths reported
- 2
- Injuries reported
- 257
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 261 adverse event reports that list this exact device (DI 10884521190375), received between Sep 18, 2017 and May 6, 2026 — classified as 2 deaths, 257 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Mechanics Altered” (132 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem260
- Mechanics Altered132
- Migration or Expulsion of Device79
- Patient Device Interaction Problem40
- Insufficient Device Problem Information19
- Material Split, Cut or Torn11
- Material Integrity Problem8
- Material Deformation6
Patient problems
- Hernia218
- Unspecified Tissue Injury217
- Pain211
- Adhesion(s)194
- Emotional Changes136
- Inflammation127
- Scar Tissue119
- Injury98
Recent adverse event reports
The 25 most recent of 261 reports, in the reporter's own words as published by the FDA.
InjuryMay 6, 2026Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED PATIENT EXPERIENCED AN UNSPECIFIC ADVERSE OUTCOME.
Patient problems: Unspecified Tissue Injury
MAUDE report 25096302 ↗InjuryApr 28, 2026Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INCISIONAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED AN UNSPECIFIED ADVERSE OUTCOME.
Patient problems: Unspecified Tissue Injury
MAUDE report 25019564 ↗InjuryApr 7, 2026Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN UMBILICAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED AN UNSPECIFIED ADVERSE OUTCOME.
Patient problems: Unspecified Tissue Injury
MAUDE report 24802577 ↗InjuryMar 6, 2026Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A VENTRAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED AN UNSPECIFIED ADVERSE OUTCOME.
Patient problems: Unspecified Tissue Injury
MAUDE report 24535948 ↗InjuryMar 2, 2026Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED ADHESIONS, ABSCESS, SEROMA, PAIN. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY, MESH REVISION, REMOVAL OF MESH.
Patient problems: Abscess; Adhesion(s); Pain; Seroma; Unspecified Tissue Injury
MAUDE report 24484267 ↗InjuryNov 17, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INCISIONAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED FISTULA, PAIN, RECURRENCE AND OBSTRUCTION. POST-OPERATIVE PATIENT TREATMENT INCLUDED COLECTOMY AND REMOVAL OF COLOCUTANEOUS FISTULA, REVISION OF TRANSVERSE LOOP COLOSTOMY, MEDICATION.
Patient problems: Fistula; Hernia; Obstruction/Occlusion; Pain; Unspecified Tissue Injury
MAUDE report 23578022 ↗InjuryNov 7, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
The patient's attorney alleged a deficiency against the device. The product was used for therapeutic treatment of a incisional hernia. It was reported that after implant, the patient experienced emotional distress, recurrence, pain, suffering, inability to be physical intimate with partner, <(>&<)> nerve damage. Post-operative patient treatment included revision surgery, hernia repair with new mesh, <(>&<)> hernia repair.
Patient problems: Distress; Hernia; Nerve Damage; Pain; Sexual Dysfunction; Unspecified Tissue Injury
MAUDE report 23500487 ↗InjuryOct 15, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A VENTRAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED ADHESIONS, RECURRENCE, PAIN, SUFFERING AND EMOTIONAL DISTRESS. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY, MESH REVISION AND HERNIA REPAIR.
Patient problems: Adhesion(s); Distress; Hernia; Pain; Unspecified Tissue Injury
MAUDE report 23304640 ↗InjurySep 9, 2025Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A VENTRAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED PAIN, RECURRENCE, INFLAMMATION, ADHESIONS, DISCOMFORT AND MESH FAILURE. POST-OPERATIVE PATIENT TREATMENT INCLUDED MEDICATION AND SURGERY TO REMOVE MESH.
Patient problems: Adhesion(s); Discomfort; Hernia; Inflammation; Pain; Unspecified Tissue Injury
MAUDE report 23000488 ↗InjuryAug 22, 2025Migration or Expulsion of Device; Material Integrity Problem; Adverse Event Without Identified Device or Use Problem; Migration or Expulsion of Device; Material Integrity Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A HERNIA. IT WAS REPORTED THAT AFTER IMPLANT; THE PATIENT EXPERIENCED EMOTIONAL DISTRESS. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY.
Patient problems: Adhesion(s); Distress; Fistula; Fluid Discharge; Hernia; Obstruction/Occlusion; Pain; Unspecified Infection; Unspecified Tissue Injury
MAUDE report 22874151 ↗InjuryAug 15, 2025Migration or Expulsion of Device; Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem; Migration or Expulsion of Device; Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INGUINAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED MESH MIGRATION, FAILED INCORPORATION, PAIN, INFECTION, RECURRENCE, INFLAMMATION, ADHESIONS, BLEEDING, FISTULA, SEROMA, PERFORATION, ABSCESS, SCARRING, SEROUS FLUID DRAINAGE, CYST, FOREIGN BODY GIANT CELL REACTION, ABDOMINAL PAIN, BOIL. POST-OPERATIVE PATIENT TREATMENT INCLUDED PARTIAL REMOVAL OF MESH, REMOVAL OF MESH, MEDICATION, HOSPITALIZATION, DEBRIDEMENT AND WOUND VAC.
Patient problems: Abdominal Pain; Abscess; Adhesion(s); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Cyst(s); Fistula; Fluid Discharge; Foreign Body Reaction; Hemorrhage/Blood Loss/Bleeding; Hernia; Inflammation; Pain; Perforation; Scar Tissue; Seroma; Unspecified Infection; Unspecified Tissue Injury
MAUDE report 22817360 ↗InjuryAug 13, 2025Migration or Expulsion of Device; Adverse Event Without Identified Device or Use Problem; Migration or Expulsion of Device; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A VENTRAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED PAIN, RECURRENCE, ADHESIONS, OBSTRUCTION, MESH DETACHMENT, INCARCERATEDHERNIA AND PARTIAL BLOCKAGE. POST-OPERATIVE PATIENT TREATMENT INCLUDED MEDICATION AND HERNIA REPAIR.
Patient problems: Adhesion(s); Hernia; Obstruction/Occlusion; Pain; Unspecified Tissue Injury
MAUDE report 22798611 ↗InjuryJul 1, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED EMOTIONAL DISTRESS. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY.
Patient problems: Adhesion(s); Distress; Hernia; Obstruction/Occlusion; Pain; Unspecified Tissue Injury
MAUDE report 22376319 ↗InjuryJun 4, 2025Migration or Expulsion of Device; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Material Split, Cut or Torn; Migration or Expulsion of Device; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Material Split, Cut or Torn
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED MESH SEPARATION, PAIN, RECURRENCE, ADHESIONS.
Patient problems: Adhesion(s); Discomfort; Emotional Changes; Hernia; Inflammation; Pain; Scar Tissue; Unspecified Tissue Injury
MAUDE report 22144517 ↗InjuryJun 4, 2025Migration or Expulsion of Device; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Material Split, Cut or Torn; Migration or Expulsion of Device; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Material Split, Cut or Torn
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED MESH SEPARATION, PAIN, RECURRENCE, ADHESIONS. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY, HERNIA REPAIR WITH NEW MESH.
Patient problems: Adhesion(s); Discomfort; Emotional Changes; Hernia; Inflammation; Pain; Scar Tissue; Unspecified Tissue Injury
MAUDE report 22144393 ↗InjuryMay 6, 2025Mechanics Altered; Adverse Event Without Identified Device or Use Problem; Mechanics Altered; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INCISIONAL VENTRAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED DEFECTIVE MESH, ABDOMINAL PAIN, RECURRENCE, ADHESIONS, DISFIGUREMENT, SCARRING, PAIN, IMPAIRMENT, LOSS OF ENJOYMENT OF LIFE, MENTAL PAIN. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY, PARTIAL REMOVAL OF MESH, HERNIA REPAIR WITH NEW MESH, HOSPITALIZATION, LYSIS OF ADHESIONS.
Patient problems: Abdominal Pain; Adhesion(s); Deformity/ Disfigurement; Emotional Changes; Hernia; Pain; Scar Tissue; Unspecified Tissue Injury
MAUDE report 21969108 ↗InjuryMar 18, 2025Migration or Expulsion of Device; Mechanics Altered; Adverse Event Without Identified Device or Use Problem; Migration or Expulsion of Device; Mechanics Altered; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INCISIONAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED MESH MIGRATION, DEFECTIVE MESH, FAILURE OF MESH, DISCOMFORT, RECURRENCE, PAIN, IMPAIRMENT, LOSS OF ENJOYMENT OF LIFE, MENTAL PAIN, DISABILITY. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY, HERNIA REPAIR WITH NEW MESH.
Patient problems: Discomfort; Emotional Changes; Hernia; Pain; Unspecified Tissue Injury
MAUDE report 21638626 ↗InjuryMar 6, 2025Mechanics Altered; Adverse Event Without Identified Device or Use Problem; Mechanics Altered; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INCISIONAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED DEFECTIVE MESH, ADHESIONS, INFLAMMATION, DISCOMFORT, SCARRING, PAIN, IMPAIRMENT, LOSS OF ENJOYMENT OF LIFE, MENTAL PAIN. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY, DISSECTION OF ADHESIONS.
Patient problems: Adhesion(s); Discomfort; Emotional Changes; Inflammation; Pain; Scar Tissue; Unspecified Tissue Injury
MAUDE report 21537111 ↗InjuryFeb 12, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INGUINAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED PAIN, RECURRENCE, ADHESIONS, AND RESTRAINT ON MOVEMENT. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY.
Patient problems: Adhesion(s); Hernia; Pain; Unspecified Tissue Injury
MAUDE report 21367582 ↗InjuryFeb 7, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A VENTRAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED PAIN, AND ADHESIONS.
Patient problems: Adhesion(s); Pain; Unspecified Tissue Injury
MAUDE report 21337222 ↗InjuryNov 5, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A VENTRAL/INCISIONAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED PAIN, RECURRENCE, ADHESIONS, POPPING, CRAMPS, UNCOMFORTABLE SITTING AND LAYING DOWN. POST-OPERATIVE PATIENT TREATMENT INCLUDED MEDICATION.
Patient problems: Adhesion(s); Cramp(s) /Muscle Spasm(s); Discomfort; Hernia; Pain; Unspecified Tissue Injury
MAUDE report 20613164 ↗InjuryOct 30, 2024Mechanics Altered; Adverse Event Without Identified Device or Use Problem; Mechanics Altered; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A VENTRAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED DEFECTIVE MESH, INFECTION, NECROSIS, ADHESIONS, SEROSAL TEAR, RECURRENCE, SCARRING, PAIN, MENTAL PAIN, IMPAIRMENT, LOSS OF ENJOYMENT OF LIFE. POST-OPERATIVE PATIENT TREATMENT INCLUDED REMOVAL OF MESH, HERNIA REPAIR WITH NEW MESH, WOUND WASHOUT, LYSIS OF ADHESIONS, DEBRIDEMENT OF NECROTIC TISSUE, REPAIR OF SEROSAL TEAR, SMALL BOWEL RESECTION, PARTIAL OMENTECTOMY, FASCIAL CLOSURE, WOUND VAC.
Patient problems: Adhesion(s); Emotional Changes; Hernia; Necrosis; Pain; Scar Tissue; Unspecified Infection; Unspecified Tissue Injury
MAUDE report 20570439 ↗InjuryOct 30, 2024Mechanics Altered; Adverse Event Without Identified Device or Use Problem; Mechanics Altered; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A VENTRAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED DEFECTIVE MESH, INFECTION, NECROSIS, ADHESIONS, SEROSAL TEAR, RECURRENCE, SCARRING, PAIN, MENTAL PAIN, IMPAIRMENT, LOSS OF ENJOYMENT OF LIFE. POST-OPERATIVE PATIENT TREATMENT INCLUDED REMOVAL OF MESH, WOUND WASHOUT, LYSIS OF ADHESIONS, DEBRIDEMENT OF NECROTIC TISSUE, REPAIR OF SEROSAL TEAR, SMALL BOWEL RESECTION, PARTIAL OMENTECTOMY, FASCIAL CLOSURE, WOUND VAC.
Patient problems: Adhesion(s); Emotional Changes; Hernia; Necrosis; Pain; Scar Tissue; Unspecified Infection; Unspecified Tissue Injury
MAUDE report 20570295 ↗InjuryOct 28, 2024Mechanics Altered; Adverse Event Without Identified Device or Use Problem; Mechanics Altered; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A VENTRAL INCISIONAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED DEFECTIVE MESH, RECURRENCE, ADHESIONS, SCARRING, PAIN, MENTAL PAIN, IMPAIRMENT, LOSS OF ENJOYMENT OF LIFE. POST-OPERATIVE PATIENT TREATMENT INCLUDED HERNIA REPAIR WITH NEW MESH, LEFT/RIGHT MYOFASCIAL CUTANEOUS RECTUS ABDOMINIS MUSCLE RELEASE, TRANSVERSUS ABDOMINIS RELEASE.
Patient problems: Adhesion(s); Discomfort; Emotional Changes; Hernia; Pain; Scar Tissue; Unspecified Tissue Injury
MAUDE report 20547199 ↗DeathAug 14, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ACCORDING TO THE REPORTER, POST-OPERATIVELY, ROBOTIC LAPAROSCOPIC VENTRAL HERNIA PROCEDURE, THE PATIENT DIED DUE TO INCARCERATED BOWEL. THE PATIENT'S CAUSE OF DEATH WAS BOWEL OBSTRUCTION NOT FROM THE MESH.
Patient problems: Insufficient Information
MAUDE report 19983298 ↗
Other Mesh, surgical, polymeric devices
- PROCEED PVPMJohnson & Johnson International Inc. · Mesh, surgical, polymeric1,233 reports
- PROCEED PCDN1Johnson & Johnson International Inc. · Mesh, surgical, polymeric744 reports
- PROCEED PCDG1Johnson & Johnson International Inc. · Mesh, surgical, polymeric1 recall1 death637 reports
- PROCEED PVPSJohnson & Johnson International Inc. · Mesh, surgical, polymeric622 reports
- ProGrip LPG1510Sofradim Production · Mesh, surgical, polymeric2 deaths616 reports
- VENTRALEX 0010302Davol Inc. · Mesh, surgical, polymeric4 deaths531 reports
- BARD 0112680Davol Inc. · Mesh, surgical, polymeric1 death494 reports
- ProGrip TEM1509GSofradim Production · Mesh, surgical, polymeric3 deaths471 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page