superDimension SDTNB1500Recalls & reported problems

Covidien LP · Triple Needle Cytology Brush;15 mm · Class 2

All models of superDimension (20)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10884521200555), received between Mar 14, 2017 and Jan 25, 2019 — classified as 2 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2

Patient problems

  • Pneumothorax2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 25, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ACCORDING TO THE REPORTER, THE PATIENT RECEIVED WAS PNEUMOTHORAX. MULTIPLE TOOLS WERE USED FOR BIOPSY. THE PHYSICIAN WAS ABLE TO COMPLETE THE CASE SUCCESSFULLY. THE PATIENT VISITED EMERGENCY ROOM (ER) IN THE EVENING ON (B)(6) 2019. A PIGTAIL WAS PLACED.

    Patient problems: Pneumothorax

    MAUDE report 8279568 ↗
  • InjuryMar 14, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A PATIENT WAS IDENTIFIED WITH PNEUMOTHORAX POST SUPERDIMENSION ENB PROCEDURE. THE PATIENT WAS ADMITTED TO INPATIENT AND A CHEST TUBE WAS PLACED.

    Patient problems: Pneumothorax

    MAUDE report 6402159 ↗

FDA clearance and classification

The FDA regulates product code BTG (brush, biopsy, bronchoscope (non-rigid)) under 21 CFR 874.4680 as a Class II device. 21 CFR 874.4680 ↗

Devices of this type normally need 510(k) clearance before sale.

Common questions about the superDimension SDTNB1500

Has the superDimension SDTNB1500 been recalled?

No FDA recall record in our data names this exact device identifier (DI 10884521200555), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the superDimension SDTNB1500?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Mar 14, 2017 and Jan 25, 2019. In those reports, the most common patient problem is “Pneumothorax” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the superDimension SDTNB1500?

None of the reports are classified as deaths, 2 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the superDimension SDTNB1500, and is it still sold?

The FDA's device database lists Covidien LP as the company responsible for it (brand superDimension, model SDTNB1500). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other BRUSH, BIOPSY, BRONCHOSCOPE (NON-RIGID) devices

All BRUSH, BIOPSY, BRONCHOSCOPE (NON-RIGID) devices →

Sources and updates