Parietene DS PPDS12 (UDI 10884521795389)Recalls & reported problems
Sofradim Production · Composite Mesh Monofilament Polypropylene Mesh with Absorbable Synthetic Film and Marking · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 11
- Deaths reported
- 0
- Injuries reported
- 8
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 10884521795389), received between Apr 13, 2023 and Jun 8, 2026 — classified as 8 injuries, 3 malfunctions.
The most frequently reported specific device problem is “Material Split, Cut or Torn” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem8
- Material Split, Cut or Torn3
- Insufficient Device Problem Information2
- Mechanics Altered2
- Migration or Expulsion of Device2
Patient problems
- Unspecified Tissue Injury7
- Pain5
- Adhesion(s)4
- Hernia4
- Inflammation4
- Emotional Changes3
- Unspecified Infection3
- Discomfort2
Recent adverse event reports
The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.
InjuryJun 8, 2026Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INCISIONAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED ADHESIONS, OBSTRUCTION, PAIN AND SUFFERING. POST-OPERATIVE PATIENT TREATMENT INCLUDED ROBOTIC-ASSISTED LYSIS OF ADHESIONS, "NLO TUBE" PLACEMENT, MESH REVISION, HOSPITALIZATION.
Patient problems: Adhesion(s); Obstruction/Occlusion; Pain; Unspecified Tissue Injury
MAUDE report 25430786 ↗InjuryJun 1, 2026Adverse Event Without Identified Device or Use Problem
ACCORDING TO THE REPORTER 10 DAYS AFTER A LAPAROSCOPIC VENTRAL HERNIA REPAIR WITH MESH, THE PATIENT WAS PRESUMED TO HAVE A BOWEL OBSTRUCTION. THERE WAS NO OBSTRUCTION, BUT INTRAOPERATIVE FINDINGS A LOT OF DILATED RED-LOOKING INTESTINES LIKE AN INFECTIOUS OR INFLAMMATORY STATE. THE MESH LOOKED FINE.
Patient problems: Inflammation; Tissue Breakdown
MAUDE report 25345828 ↗InjuryApr 13, 2026Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INCISIONAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED AN UNSPECIFIED ADVERSE OUTCOME.
Patient problems: Unspecified Tissue Injury
MAUDE report 24860199 ↗MalfunctionFeb 11, 2026Material Split, Cut or Torn
IT WAS REPORTED THAT DURING THE LAPAROSCOPIC UMBILICAL HERNIA REPAIR THROUGH INTRAPERITONEAL ONLAY MESH TECHNIQUE, AFTER INSERTION TO THE PATIENT, THE COLLAGEN LAYER PEELED OFF FROM THE POLYPROPYLENE MESH WHILE ORIENTING THE MESH TOWARDS THE 3CM HERNIA DEFECT. THE WOUND WAS CLOSED USING A SUTURE, AND FIXATION WAS ACHIEVED WITH 12 POINTS USING A TACKER. TO AVOID POST-OPERATIVE COMPLICATIONS, THE MESH WAS DISCARDED AND ANOTHER MESH OF THE SAME SIZE WAS USED TO COMPLETE THE PROCEDURE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24318559 ↗InjurySep 19, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF A HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED EMOTIONAL DISTRESS. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY.
Patient problems: Distress; Unspecified Tissue Injury
MAUDE report 23099676 ↗InjuryJun 20, 2025Migration or Expulsion of Device; Adverse Event Without Identified Device or Use Problem; Migration or Expulsion of Device; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN UMBILICAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED PAIN, RECURRENCE, ADHESIONS, BALLED UP MESH. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY, REMOVAL OF MESH, MEDICATION, PRIMARY HERNIA REPAIR AND HERNIA REPAIR WITH NEW MESH.
Patient problems: Adhesion(s); Hernia; Pain; Unspecified Tissue Injury
MAUDE report 22301006 ↗MalfunctionMar 4, 2024Material Split, Cut or Torn; Material Split, Cut or Torn
ACCORDING TO THE REPORTER, THE SURGEON MADE COMMENT ABOUT HAVING AN ISSUE WITH DELAMINATION IN THE PAST IN A VENTRAL HERNIA REPAIR CASE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18833432 ↗MalfunctionJan 19, 2024Material Split, Cut or Torn; Material Split, Cut or Torn
ACCORDING TO THE REPORTER, INTRA-OPERATIVELY OF A LAPAROSCOPIC VENTRAL HERNIA, WHEN THE DEVICE WAS OPENED OUT FROM THE PACKAGE, THE PREFIXED SUTURES WERE SEPARATED. THE SUTURES WERE DAMAGED AND NOT FIXED WITH THE MESH. ANOTHER DEVICE WAS USED TO COMPLETE THE CASE.
Patient problems: Insufficient Information
MAUDE report 18547581 ↗InjuryAug 17, 2023Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED EMOTIONAL DISTRESS. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY.
Patient problems: Adhesion(s); Discomfort; Distress; Emotional Changes; Hernia; Inflammation; Pain; Unspecified Gastrointestinal Problem; Unspecified Infection; Unspecified Tissue Injury
MAUDE report 17565501 ↗InjuryMay 11, 2023Mechanics Altered; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Mechanics Altered; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information
THE PATIENT¿S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INCISIONAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED ABDOMINAL PAIN, RECURRENCE, DEFECTIVE MESH, FISTULOUS TRACT, INFLAMMATION, SCARIFICATION, PAIN, MENTAL PAIN, SUFFERING, DISABILITY, IMPAIRMENT, AND LOSS OF ENJOYMENT OF LIFE. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY, TAKE DOWN OF FISTULA, AND HERNIA REPAIR.
Patient problems: Abdominal Pain; Discomfort; Emotional Changes; Fistula; Hernia; Inflammation; Nausea; Pain; Scar Tissue; Unspecified Infection; Unspecified Tissue Injury
MAUDE report 16911594 ↗InjuryApr 13, 2023Migration or Expulsion of Device; Mechanics Altered; Adverse Event Without Identified Device or Use Problem; Migration or Expulsion of Device; Mechanics Altered; Adverse Event Without Identified Device or Use Problem
THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. THE PRODUCT WAS USED FOR THERAPEUTIC TREATMENT OF AN INCISIONAL HERNIA. IT WAS REPORTED THAT AFTER IMPLANT, THE PATIENT EXPERIENCED FAILURE OF MESH, MESH SEPARATION, DEFECTIVE MESH, RECURRENCE, ADHESIONS, PAIN, HEMATOMA, INFLAMMATION, INFECTION, SCARRING, NERVE DAMAGE, MENTAL PAIN, DISABILITY, IMPAIRMENT, LOSS OF ENJOYMENT OF LIFE. POST-OPERATIVE PATIENT TREATMENT INCLUDED REVISION SURGERY, REMOVAL OF MESH.
Patient problems: Adhesion(s); Emotional Changes; Foreign Body Reaction; Hematoma; Hernia; Inflammation; Nerve Damage; Pain; Scar Tissue; Unspecified Infection; Unspecified Tissue Injury
MAUDE report 16737113 ↗
Other Mesh, surgical, polymeric devices
- PROCEED PVPMJohnson & Johnson International Inc. · Mesh, surgical, polymeric1,233 reports
- PROCEED PCDN1Johnson & Johnson International Inc. · Mesh, surgical, polymeric744 reports
- PROCEED PCDG1Johnson & Johnson International Inc. · Mesh, surgical, polymeric1 recall1 death637 reports
- PROCEED PVPSJohnson & Johnson International Inc. · Mesh, surgical, polymeric622 reports
- ProGrip LPG1510Sofradim Production · Mesh, surgical, polymeric2 deaths616 reports
- VENTRALEX 0010302Davol Inc. · Mesh, surgical, polymeric4 deaths531 reports
- BARD 0112680Davol Inc. · Mesh, surgical, polymeric1 death494 reports
- ProGrip TEM1509GSofradim Production · Mesh, surgical, polymeric3 deaths471 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page