AVAmax VMX00CTRecalls & reported problems
Carefusion 2200, Inc · AVAmax PLUS Bone Cement Delivery System · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10885403002113), received between Apr 20, 2018 and Apr 20, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Break1
- Detachment Of Device Component1
- Difficult to Remove1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 20, 2018Break; Detachment Of Device Component; Difficult to Remove
PATIENT WAS HAVING A VERTEBROPLASTY. RADIOLOGIST WAS ATTEMPTING TO REPOSITION THE VERTEBRAL AUGMENTATION NEEDLE TO ADD ADDITIONAL CEMENT AND THE NEEDLE WOULD NOT MOVE. RADIOLOGIST MADE MULTIPLE ATTEMPTS TO REMOVE AND THEN TRIED TO REMOVE WITH THE USE OF HEMOSTATS AND THEN THE NEEDLE BROKE OFF WITH APPROXIMATELY 2 - 2.5 INCHES ABOVE PATIENT'S SKIN. RADIOLOGIST CONTACTED AN INTERVENTIONAL RADIOLOGIST TO DISCUSS CASE. PLANS TO TRANSFER THE PATIENT TO SVI FOR REMOVAL ON THE NEXT MORNING. THE NEEDLE ENTRY SITE WAS PADDED WITH A NEEDLE COVER AND DRESSED. PATIENT WAS GIVEN ANTIBIOTICS PROPHYLACTICALLY. PATIENT PROCEDURE WAS PERFORMED AT SAINT VINCENT INFIRMARY IN LITTLE ROCK, AR AND INTERVENTIONAL RADIOLOGIST WAS ABLE TO REMOVE THE ENTIRE NEEDLE REMAINING IN THE PATIENT (B)(6) 2018. T11 VERTEBRAL FRACTURE WAS REASON FOR THE PROCEDURE. ROUTE: INTRAVERTEBRAL. IS THE PRODUCT COMPOUNDED: NO. IS THE PRODUCT OVER-THE-COUNTER: NO.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7450559 ↗
FDA clearance and classification
The FDA regulates product code NDN (cement, bone, vertebroplasty) under 21 CFR 888.3027 as a Class II device. 21 CFR 888.3027 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the AVAmax VMX00CT
Has the AVAmax VMX00CT been recalled?
No FDA recall record in our data names this exact device identifier (DI 10885403002113), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the AVAmax VMX00CT?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Apr 20, 2018. That report lists device problems “Break” (1), “Detachment Of Device Component” (1) and “Difficult to Remove” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the AVAmax VMX00CT?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the AVAmax VMX00CT, and is it still sold?
The FDA's device database lists Carefusion 2200, Inc as the company responsible for it (brand AVAmax, model VMX00CT). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Cement, Bone, Vertebroplasty devices
- CONFIDENCE SPINAL CEMENT SYSTEM 283910000Medos International Sàrl · CEMENT, BONE, VERTEBROPLASTY5 deaths159 reports
- CONFIDENCE SPINAL CEMENT SYSTEM 283913000Medos International Sàrl · CEMENT, BONE, VERTEBROPLASTY8 deaths143 reports
- KYPHON® Xpede™ Bone Cement and KYPHON® Mixer Pack CX01BMedtronic Sofamor Danek, Inc. · CEMENT, BONE, VERTEBROPLASTY3 deaths66 reports
- SYNFLATE 03.804.701SSynthes GmbH · CEMENT, BONE, VERTEBROPLASTY60 reports
- KYPHON® HV-R® Bone Cement C01AMedtronic Sofamor Danek, Inc. · CEMENT, BONE, VERTEBROPLASTY57 reports
- iVAS 0705315000Stryker Corporation · CEMENT, BONE, VERTEBROPLASTY1 recall3 reports
- Cortoss 2101-0005Stryker Corporation · CEMENT, BONE, VERTEBROPLASTY1 recall3 reports
- Cortoss 2101-0010Stryker Corporation · CEMENT, BONE, VERTEBROPLASTY1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page