AVAmax VMX00CTRecalls & reported problems
Carefusion 2200, Inc · AVAmax PLUS Bone Cement Delivery System · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10885403002113), received between Apr 20, 2018 and Apr 20, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Break1
- Detachment Of Device Component1
- Difficult to Remove1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 20, 2018Break; Detachment Of Device Component; Difficult to Remove
PATIENT WAS HAVING A VERTEBROPLASTY. RADIOLOGIST WAS ATTEMPTING TO REPOSITION THE VERTEBRAL AUGMENTATION NEEDLE TO ADD ADDITIONAL CEMENT AND THE NEEDLE WOULD NOT MOVE. RADIOLOGIST MADE MULTIPLE ATTEMPTS TO REMOVE AND THEN TRIED TO REMOVE WITH THE USE OF HEMOSTATS AND THEN THE NEEDLE BROKE OFF WITH APPROXIMATELY 2 - 2.5 INCHES ABOVE PATIENT'S SKIN. RADIOLOGIST CONTACTED AN INTERVENTIONAL RADIOLOGIST TO DISCUSS CASE. PLANS TO TRANSFER THE PATIENT TO SVI FOR REMOVAL ON THE NEXT MORNING. THE NEEDLE ENTRY SITE WAS PADDED WITH A NEEDLE COVER AND DRESSED. PATIENT WAS GIVEN ANTIBIOTICS PROPHYLACTICALLY. PATIENT PROCEDURE WAS PERFORMED AT SAINT VINCENT INFIRMARY IN LITTLE ROCK, AR AND INTERVENTIONAL RADIOLOGIST WAS ABLE TO REMOVE THE ENTIRE NEEDLE REMAINING IN THE PATIENT (B)(6) 2018. T11 VERTEBRAL FRACTURE WAS REASON FOR THE PROCEDURE. ROUTE: INTRAVERTEBRAL. IS THE PRODUCT COMPOUNDED: NO. IS THE PRODUCT OVER-THE-COUNTER: NO.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7450559 ↗
Other Cement, Bone, Vertebroplasty devices
- CONFIDENCE SPINAL CEMENT SYSTEM 283910000Medos International Sàrl · CEMENT, BONE, VERTEBROPLASTY5 deaths163 reports
- CONFIDENCE SPINAL CEMENT SYSTEM 283913000Medos International Sàrl · CEMENT, BONE, VERTEBROPLASTY8 deaths146 reports
- KYPHON® Xpede™ Bone Cement and KYPHON® Mixer Pack CX01BMedtronic Sofamor Danek, Inc. · CEMENT, BONE, VERTEBROPLASTY3 deaths67 reports
- SYNFLATE 03.804.701SSynthes GmbH · CEMENT, BONE, VERTEBROPLASTY60 reports
- KYPHON® HV-R® Bone Cement C01AMedtronic Sofamor Danek, Inc. · CEMENT, BONE, VERTEBROPLASTY57 reports
- iVAS 0705315000Stryker Corporation · CEMENT, BONE, VERTEBROPLASTY1 recall3 reports
- Cortoss 2101-0005Stryker Corporation · CEMENT, BONE, VERTEBROPLASTY1 recall3 reports
- iVAS 0705310000Stryker Corporation · CEMENT, BONE, VERTEBROPLASTY1 recall1 report
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.