Skip to content

PeritX 50-9510Recalls & reported problems

Carefusion 2200, Inc · PeritX Drainage Kit, 2000 mL · Class 2 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10885403222412), received between May 19, 2025 and Dec 18, 2025 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 2 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Fluid/Blood Leak1
  • Leak/Splash1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 18, 2025Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT FOUR PERITX BAGS WERE LEAKING AT THE SEALED GASKET. IT WAS ALSO MENTIONED THAT THE PACKS ARE LEAKING AT THE SEALED GASKET AND SPOUT CONNECTION. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23842285 ↗
  • InjuryMay 19, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED BY THE CUSTOMER THAT THE NURSE WAS SPLASHED IN THE FACE AND EYES WITH THE PATIENT'S FLUID AND WAS TREATED ACCORDING TO THE OCCUPATIONAL HEALTH AND SAFETY (OHS) PROCESS. IT WAS FURTHER REPORTED THAT BLOOD WORK WAS DONE AS PART OF MEDICAL INTERVENTION; HOWEVER, BLOOD RESULTS ARE UNKNOWN.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 22049101 ↗
  • MalfunctionMay 19, 2025Leak/Splash; Leak/Splash

    IT WAS REPORTED BY THE CUSTOMER THAT THE PERITX DRAINAGE BAG CAP SYSTEM HAD A LEAK, EVEN AFTER TIGHTENED THE DRAINAGE BAG CONTINUED TO LEAK. IT WAS FURTHER REPORTED THAT THE LEAK OCCURRED FROM THE BOTTOM DRAINAGE VALVE OF THE PERITX BAG.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22049098 ↗

Other Peritoneal, drainage catheter for refractory ascites, long-term indwelling devices

All Peritoneal, drainage catheter for refractory ascites, long-term indwelling devices →