Skip to content

Optetrak Logic 02-012-41-3535Recalls & reported problems

Exactech, Inc. · Class 2 · Implant

All models of Optetrak Logic (408)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10885862003201), received between Mar 6, 2023 and Apr 14, 2026 — classified as 2 injuries.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

2 other recalls cover devices cleared under the same FDA submission (K093360); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Detachment of Device or Device Component1
  • Loosening of Implant Not Related to Bone-Ingrowth1

Patient problems

  • Aseptic loosening1
  • Joint effusion1
  • Osteolysis1
  • Pain1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 14, 2026Loosening of Implant Not Related to Bone-Ingrowth

    IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INITIAL TOTAL KNEE ARTHROPLASTY ON THE LEFT SIDE. SUBSEQUENTLY, THE PATIENT EXPERIENCED JOINT EFFUSION, OSTEOLYSIS AND ASEPTIC LOOSENING. AS A RESULT, APPROXIMATELY SIX YEARS AND NINE MONTHS POST-SURGERY, THE PATIENT UNDERWENT A REVISION. IT WAS NOTED THAT "THE INITIAL IMPRESSION WAS THAT THE IMPLANTS WERE FIXED, BUT THEY CAME OFF THE DISTAL FEMUR & PROXIMAL TIBIA WITHOUT MUCH EFFORT. THIS PATIENT HAD SEVERE OSTEOLYSIS OF THE BONE. THIS IS PARTICULARLY WEAR DEBRIS OSTEOLYSIS BECAUSE OF FAILURE OF THE MEDIAL ASPECT OF THE TIBIAL INSERT THAT THE POSTERIOR ASPECT OF THE MEDIAL PORTION OF THE TIBIAL INSERT WAS FRACTURED AND MORSELIZED. THE INSERT, HOWEVER, REMAINED WELL FIXED. THERE WAS NO EVIDENCE OF INFECTION. THERE WAS NO FRACTURE." PATIENT WAS LAST KNOWN TO BE IN STABLE CONDITION FOLLOWING THE EVENT. NO FURTHER IMPACT TO THE PATIENT WAS REPORTED. NO ADDITIONAL INFORMATION IS AVAILABLE. THIS IS REPORT 3 OF 3 FOR THIS EVENT/PATIENT.

    Patient problems: Aseptic loosening; Joint effusion; Osteolysis

    MAUDE report 24875521 ↗
  • InjuryMar 6, 2023Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem; Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem

    AS REPORTED, APPROXIMATELY TWELVE YEARS POST INITIAL BILATERAL TKA, PATIENT LEFT KNEE WAS REVISED DUE TO PAIN. COMPONENTS WERE WELL FIXED. THE INSERT WAS FOUND TO HAVE AN UNUSUALLY METAL PIECE IMBEDDED INTO THE TOP LAYER. IT APPEARED THAT THE METAL CAPS ON THE TIBIAL BASEPLATE THAT COVER THE HOLE FOR POSSIBLE AUGMENTS WERE POTENTIALLY NEVER CAPTURED UNDER THE INSERT DURING THE INITIAL PROCEDURE. PATIENT CHOSE A DIFFERENT COMPANY FOR THE REVISION WITH SURGEON DISCUSSION. EXPLANTS NOT AVAILABLE. PATIENT LEFT IN STABLE CONDITION. NO FURTHER INFORMATION.

    Patient problems: Pain

    MAUDE report 16490077 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K093360. One submission often covers many models, so check the product and lot details in each record.

  • Z-0021-2022 · Aug 30, 2021 · Open, Classified
    OPTETRAK LOGIC Polyethylene Tibial Inserts, labeled as the following: a. OPTETRAK Logic PS Tibial Inserts, Product Line 02-012-35-XXXX; b. OPTETRAK Logic PSC Tibial Inser
  • Z-2310-2012 · Aug 19, 2011 · Terminated
    OPTETRAK LOGIC TIBIAL INSERT POSTERIOR STABILIZED***Match Component Colors 6 YELLOW, 11mm, Use with LOGIC Femoral and Tibial Components***REF 02-012-35-6011. There are three produ

Other Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices

All Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page