Acumatch A Series 120-01-50Recalls & reported problems
Exactech, Inc. · Class 2 · Implant
All models of Acumatch A Series (94)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10885862019721), received between Jul 18, 2023 and May 22, 2024 — classified as 2 injuries.
The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (2 reports).
2 other recalls cover devices cleared under the same FDA submission (K993082); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Loosening of Implant Not Related to Bone-Ingrowth2
Patient problems
- Failure of Implant2
- Metal Related Pathology1
- Osteolysis1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMay 22, 2024Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
IT WAS REPORTED THAT THIS 86 Y/O FEMALE PATIENT'S LEFT HIP WAS REVISED. PATIENT HAD A DISSOCIATED CUP. STEM WAS LEFT IN, ONLY FEMORAL HEAD WAS REVISED TO EXACTECH. ACETABULAR SIDE WAS REVISED TO A COMPETITORS DEVICE. PATIENT WAS LAST KNOWN TO BE IN STABLE CONDITION FOLLOWING THE EVENT . DEVICES ARE NOT RETURNING - HOSPITAL POLICY.
Patient problems: Failure of Implant
MAUDE report 19373914 ↗InjuryJul 18, 2023Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
AS REPORTED, APPROXIMATELY 15 YEARS POST OP INITIAL RIGHT THA, THIS 79 Y/O FEMALE PATIENT WAS REVISED DUE TO THE ACETABULAR COMPONENTS BECOMING LOOSE. PATIENT'S FEMORAL HEAD WAS REVISED USING EXACTECH. 170-32-50, BIOLOX DELTA OPTION HEAD, 32MM AND 170-50-03, BIOLOX DELTA ADAPTER, 12/14 +3.5MM, THE ACETABULAR SIDE WERE REVISED TO COMPETITORS DEVICE. PATIENT WAS LAST KNOWN TO BE IN STABLE CONDITION FOLLOWING THE EVENT. UNKNOWN MEDICAL HISTORY. NO PICTURES OR X-RAYS PROVIDED. DEVICE NOT BEING RETURNED DUE TO HOSPITAL POLICY.
Patient problems: Failure of Implant; Metal Related Pathology; Osteolysis
MAUDE report 17343117 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K993082. One submission often covers many models, so check the product and lot details in each record.
- Z-1734-2022 · Aug 11, 2022 · Open, ClassifiedGXL acetabular liners, orthopedic hip implant component. Product Line Numbers: a. ACUMATCH 0 DEGREE LINER 28MM 46MM, REF 130-28-05; b. ACUMATCH 0 DEGREE LINER 28MM 48MM, REF 13
- Z-1031-2017 · Nov 7, 2016 · TerminatedAcuMatch A-Series Connexion GXL Enhanced Polyethylene Acetabular Liner, 15, +5 mm Lateralized, 36 mm I.D., Size J.
Other Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented devices
- PINNACLE 1217-25-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED735 reports
- NA 1365-52-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED683 reports
- APEX 1246-03-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED3 deaths613 reports
- PINNACLE 1217-20-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED2 deaths590 reports
- PINNACLE 1217-30-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED1 death484 reports
- NA 1365-53-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED404 reports
- PINNACLE ALTRX 1221-36-054Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED388 reports
- PINNACLE ALTRX 1221-32-050Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED386 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page